42 resultados para Surface Emg Variables
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Mouth breathing may cause changes in muscle activity, because an upper airway obstruction leads may cause a person to extend his/her head forward, demanding a higher inspiratory effort on the accessory muscles (sternocleidomastoids). This purpose of this study is to compare, using electromyography (EMG), the activity pattern the sternocleidomastoid and upper trapezius muscles in mouth breathing children and nasal breathing children. Forty-six children, ages 8-12 years, 33 male and 13 female were included. The selected children were divided into two groups: Group I consisted of 26 mouth breathing children, and Group II, 20 nasal breathing children. EMG recordings were made using surface electrodes bilaterally in the areas of the sternocleidomastoideus and upper trapezius muscles, while relaxed and during maximal voluntary contraction. The data were analyzed using the Kruskall-Wallis statistical test. The results indicated higher activity during relaxation and lower activity during maximal voluntary contraction in mouth breathers when compared to the nasal breathers. It is suggested that the activity pattern of the sternocleidomastoid and upper trapezius muscles differs between mouth breathing children and nasal breathing children. This may be attributed to changes in body posture which causes muscular imbalance. Because of the limitations of surface EMG, the results need to be confirmed by adding force measurements and repeating the experiments with matched subjects. Copyright © 2004 by CHROMA, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the efficiency of the Pro-Fono Facial Exerciser (Pro-Fono Productos Especializaclos para Fonoaudiologia Ltda.., Barueri/SP, Brazil) to decrease bruxism, as well as the correlation between the masseter and the buccinator muscles using electromyography (EMG). In this study, 39 individuals ranging from 23 to 48 years of age were selected from a dental school and then underwent surface EMG at three different periods of time: 0, 10, and 70 days. They were divided into a normal control group, a bruxer control group (without device), and an experimental bruxer group who used the device. The bruxer group showed a greater masseter EMG amplitude when compared to the normal group, while the experimental group had deceased activity with a reduction in symptoms. The buccinator EMG spectral analysis of the experimental bruxist group showed asynchronous contractions of the masseter muscle (during jaw opening) after using the Pr6-Fono Facial Exerciser. The normal group also showed asynchronous contractions. Upon correlation of the data between these muscles, the inference is that there is a reduction in bruxism when activating the buccinator muscle.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Oliveira, AS, Greco, CC, Pereira, MP, Figueira, TR, de Araujo Ruas, VD, Goncalves, M, and Denadai, BS. Physiological and neuromuscular profile during a Bodypump session: acute responses during a high-resistance training session. J Strength Cond Res 23(2): 579-586, 2009-The main purposes of this study were 1) to describe and to compare blood lactate ([La]), heart rate (HR), and electromyographic (EMG) parameters during high-repetition training sessions (HRTSs), 2) to analyze the influence of physical fitness levels in these parameters, and, 3) to analyze the relationship between metabolic ([La]) and neuromuscular (EMG) responses during the HRTS. Fifteen healthy untrained women (21.7 +/- 2.1 years) performed an HRTS called Bodypump for 1 hour, which incorporated the use of variable free weights and high repetitions in a group setting. This session involved 10 music selections (M1-M10) containing resistive exercises for different muscle groups. After music selections 2 (M2), 4 (M4), 6 (M6), 7 (M7), and 9 (M9), [La], HR, and EMG (vastus medialis [VM], vastus lateralis [VL], iliocostalis lumborum [IC], and longissimus thoracis <) were determined. The [La] (M2, 4.00 +/- 1.45 mM; M7, 5.02 +/- 1.73 mM) and HR (M2, 153.64 +/- 18.89 bpm; M7, 16.14 +/- 20.14 bpm) obtained at M2 and M7 were similar but were significantly higher than the other moments of the session. However, EMG (root mean square [RMS]) at M2 (VL, VM, and LT) was lower than at M7. There was no significant correlation of strength and aerobic physical fitness with [La], RMS. In the same way, there was no significant correlation of [La] with RMS at M2 and M7. on the basis of our data, we can conclude that metabolic, cardiovascular, and EMG variables present different and independent behavior during an HRTS. Accordingly, for neuromuscular conditions during HRTS, it seems to be enough to induce improvement in the muscular strength of inferior limbs in untrained subjects.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to determine the time to restore the biceps brachii (BB) electromyographic (EMG) activity after the biceps curl (BC) exercise, at different intensities. Ten males performed initially maximal voluntary isometric contractions (MVC) of the elbow flexors, followed by one isometric submaximal contraction at 50% MVC (reference contraction). After this, four bouts of the BC at 25%, 30%, 35%, and 40% 1 RM during 1 minute (randomly assigned, with 10 minutes rest between them) were performed. During the rest intervals at preestablished moments (15 seconds, 1, 3, 5, and 10 min), isometric 50% MVC were performed. The EMG variables (root mean square [RMS], zero crossings [ZC], median frequency, [MF] and peak power [PP]) at rest were compared with reference values. Immediately after the exercise, RMS and PP increased, while ZC and MF decreased, indicating fatigue. After 1 minute most of the variables were similar to the reference. Different load levels did not affect the EMG recovery. In conclusion, the EMG variables recovered after 1 minute rest, indicating the optimal muscular condition for subsequent bouts. Copyright © Taylor & Francis Group, LLC.
Resumo:
The purpose of this study was to compare the antagonist coactivation of the local and global trunk muscles during mat-based exercises of Skilled Modern Pilates. Twelve women performed five exercises and concurrently, surface EMG from internal oblique (OI), multifidus (MU), rectus abdominis (RA) and iliocostalis lumborum (IL) muscles was recorded bilaterally. The percentage of antagonist coactivation between local (OI/MU) and global muscles (RA/IL) was calculated. Individuals new to the practice of these exercises showed differences in coactivation of the trunk muscles between the exercises and these results were not similar bilaterally. Thus, in clinical practice, the therapist should be aware of factors such as compensation and undesirable rotation movements of the trunk. Moreover, the coactivation of global muscles was higher bilaterally in all exercises analyzed. This suggests that the exercises of Skilled Modern Pilates only should be performed after appropriate learning and correct execution of all principles, mainly the Centering Principle. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: Sleep bruxism is common among the various oromotor alterations found in individuals with cerebral palsy (CP). Few studies have investigated the use of the mastication device denominated hyperbola (HB) and none was found describing the use of such a device for the treatment of bruxism in children with CP. The aim of the present study was to evaluate the effect of the HB on electromyographic (EMG) activity in the jaw-closing muscles and the reduction in sleep bruxism in a child with CP using surface EMG analysis before and after nine months of treatment. Methods: A seven-year-old boy with severe spastic CP and sleep bruxism was enrolled in this study. The HB was chosen as the treatment option for sleep bruxism in this case because the child did not accept an occlusal splint. The HB has a hyperbolic shape and is made of soft, non-toxic, odorless, tasteless silicone. There are five different sizes of HB manufactured based on the diversity of tooth sizes. This device produces proprioceptive excitation in the dentoalveolar nerve, spindles and Golgi tendon organs. HB has been employed for the treatment of temporomandibular disorder, abnormal oro-dental development, abnormal occlusion, xerostomy, halitosis and bruxism. HB therapy was performed for 5 min six times a day over a nine-week period. Surface EMG of the mandible at rest and during maximum contraction was performed on the masseter and temporalis muscles bilaterally to evaluate electromyographic activity before and after nine months of HB usage. Results: HB usage led to a visible tendency toward the reorganization of mastication dynamics, achieving a marked balance in electromyographic activity of the jaw-closing muscles and improving the child's quality of life. Conclusion: Based on the findings of the present study, this noninvasive therapy may be useful for individuals with cerebral palsy due to its positive effects and low cost, which allows its use in the public health realm. Further clinical studies with a larger sample size are needed to validate these results and allow the development of a new treatment protocol for patients with spastic cerebral palsy. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objective of this work was to evaluate the effect of environmental variables on dairy buffaloes physiology in two different places after milking, shaded plus artificial ventilation and another one non-shaded, in Ribeira Valley, São Paulo State, Brazil. Data on the respiratory rate (RR) and the surface temperature (ST) at udder, neckmiddle, forehead, back middle and rump were collected in 12 dairy buffaloes at autumn. In the same way, it were recorded the black globe temperature in the sun (GTS) and in the shade (GTNS), air temperature and wind speed at padronized height of 1.60 meters. All data were collected at 10:30am and 1:30pm. The results showed statistical difference among black globe temperature, wind speed, RR and ST (P<0.01) in two treatments.The results showed the necessity of protection against the solar radiation in the buffaloes, even in periods of warm climates.
Resumo:
The influence of 2 different levels of the inspired oxygen fraction (FiO(2)) on blood gas variables was evaluated in dogs with high intracranial pressure (ICP) during propofol anesthesia (induction followed by a continuous rate infusion [CRI] of 0.6 mg/kg/min) and intermittent positive pressure ventilation (IPPV). Eight adult mongrel dogs were anesthetized on 2 occasions, 21 d apart, and received oxygen at an FiO(2) of 1.0 (G100) or 0.6 (G60) in a randomized crossover fashion. A fiberoptic catheter was implanted on the surface of the right cerebral cortex for assessment of the ICP. An increase in the ICP was induced by temporary ligation of the jugular vein 50 min after induction of anesthesia and immediately after baseline measurement of the ICP. Blood gas measurements were taken 20 min later and then at 15-min intervals for 1 h. Numerical data were submitted to Morrison's multivariate statistical methods. The ICP, the cerebral perfusion pressure and the mean arterial pressure did not differ significantly between FiO(2) levels or measurement times after jugular ligation. The only blood gas values that differed significantly (P < 0.05) were the arterial oxygen partial pressure, which was greater with G100 than with G60 throughout the procedure, and the venous haemoglobin saturation, that was greater with G100 than with G60 at M0. There were no significant differences between FiO(2) levels or measurement times in the following blood gas variables: arterial carbon dioxide partial pressure, arterial hemoglobin saturation, base deficit, bicarbonate concentration, pH, venous oxygen partial pressure, venous carbon dioxide partial pressure and the arterial-to-end-tidal carbon dioxide difference.
Resumo:
A study was carried out to elaborate response surface models using broiler performance data recovered from literature in order to predict performance and elaborate economic analyses. Nineteen studies published between 1995 and 2005 were retrieved using the systematic literature review method. Weight gain and feed conversion data were collected from eight studies that fulfilled the pre-established inclusion criteria, and a response surface model was adjusted using crude protein, environmental temperature, and age as independent variables. The models produced for weight gain (r² = 0.93) and feed conversion (r² = 0.85) were accurate, precise, and not biased. Protein levels, environmental temperature and age showed linear and quadratic effects on weight gain and feed conversion. There was no interaction between protein level and environmental temperature. Age and crude protein showed interaction for weight gain and feed conversion, whereas interaction between age and temperature was detected only for weight gain. It was possible to perform economic analyses to determine maximum profit as a function of the variables that were included in the model. It was concluded that the response surface models are effective to predict the performance of broiler chickens and allow the elaboration of economic analyses to optimize profit.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)