9 resultados para Surface Emg
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Mouth breathing may cause changes in muscle activity, because an upper airway obstruction leads may cause a person to extend his/her head forward, demanding a higher inspiratory effort on the accessory muscles (sternocleidomastoids). This purpose of this study is to compare, using electromyography (EMG), the activity pattern the sternocleidomastoid and upper trapezius muscles in mouth breathing children and nasal breathing children. Forty-six children, ages 8-12 years, 33 male and 13 female were included. The selected children were divided into two groups: Group I consisted of 26 mouth breathing children, and Group II, 20 nasal breathing children. EMG recordings were made using surface electrodes bilaterally in the areas of the sternocleidomastoideus and upper trapezius muscles, while relaxed and during maximal voluntary contraction. The data were analyzed using the Kruskall-Wallis statistical test. The results indicated higher activity during relaxation and lower activity during maximal voluntary contraction in mouth breathers when compared to the nasal breathers. It is suggested that the activity pattern of the sternocleidomastoid and upper trapezius muscles differs between mouth breathing children and nasal breathing children. This may be attributed to changes in body posture which causes muscular imbalance. Because of the limitations of surface EMG, the results need to be confirmed by adding force measurements and repeating the experiments with matched subjects. Copyright © 2004 by CHROMA, Inc.
Resumo:
The aim of this study was to evaluate the efficiency of the Pro-Fono Facial Exerciser (Pro-Fono Productos Especializaclos para Fonoaudiologia Ltda.., Barueri/SP, Brazil) to decrease bruxism, as well as the correlation between the masseter and the buccinator muscles using electromyography (EMG). In this study, 39 individuals ranging from 23 to 48 years of age were selected from a dental school and then underwent surface EMG at three different periods of time: 0, 10, and 70 days. They were divided into a normal control group, a bruxer control group (without device), and an experimental bruxer group who used the device. The bruxer group showed a greater masseter EMG amplitude when compared to the normal group, while the experimental group had deceased activity with a reduction in symptoms. The buccinator EMG spectral analysis of the experimental bruxist group showed asynchronous contractions of the masseter muscle (during jaw opening) after using the Pr6-Fono Facial Exerciser. The normal group also showed asynchronous contractions. Upon correlation of the data between these muscles, the inference is that there is a reduction in bruxism when activating the buccinator muscle.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to compare the antagonist coactivation of the local and global trunk muscles during mat-based exercises of Skilled Modern Pilates. Twelve women performed five exercises and concurrently, surface EMG from internal oblique (OI), multifidus (MU), rectus abdominis (RA) and iliocostalis lumborum (IL) muscles was recorded bilaterally. The percentage of antagonist coactivation between local (OI/MU) and global muscles (RA/IL) was calculated. Individuals new to the practice of these exercises showed differences in coactivation of the trunk muscles between the exercises and these results were not similar bilaterally. Thus, in clinical practice, the therapist should be aware of factors such as compensation and undesirable rotation movements of the trunk. Moreover, the coactivation of global muscles was higher bilaterally in all exercises analyzed. This suggests that the exercises of Skilled Modern Pilates only should be performed after appropriate learning and correct execution of all principles, mainly the Centering Principle. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: Sleep bruxism is common among the various oromotor alterations found in individuals with cerebral palsy (CP). Few studies have investigated the use of the mastication device denominated hyperbola (HB) and none was found describing the use of such a device for the treatment of bruxism in children with CP. The aim of the present study was to evaluate the effect of the HB on electromyographic (EMG) activity in the jaw-closing muscles and the reduction in sleep bruxism in a child with CP using surface EMG analysis before and after nine months of treatment. Methods: A seven-year-old boy with severe spastic CP and sleep bruxism was enrolled in this study. The HB was chosen as the treatment option for sleep bruxism in this case because the child did not accept an occlusal splint. The HB has a hyperbolic shape and is made of soft, non-toxic, odorless, tasteless silicone. There are five different sizes of HB manufactured based on the diversity of tooth sizes. This device produces proprioceptive excitation in the dentoalveolar nerve, spindles and Golgi tendon organs. HB has been employed for the treatment of temporomandibular disorder, abnormal oro-dental development, abnormal occlusion, xerostomy, halitosis and bruxism. HB therapy was performed for 5 min six times a day over a nine-week period. Surface EMG of the mandible at rest and during maximum contraction was performed on the masseter and temporalis muscles bilaterally to evaluate electromyographic activity before and after nine months of HB usage. Results: HB usage led to a visible tendency toward the reorganization of mastication dynamics, achieving a marked balance in electromyographic activity of the jaw-closing muscles and improving the child's quality of life. Conclusion: Based on the findings of the present study, this noninvasive therapy may be useful for individuals with cerebral palsy due to its positive effects and low cost, which allows its use in the public health realm. Further clinical studies with a larger sample size are needed to validate these results and allow the development of a new treatment protocol for patients with spastic cerebral palsy. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.
Resumo:
The use of low-level laser (LLL) may be an useful tool to promote reduction of muscular pain caused by TMD. Aim: This study evaluated the immediate efficacy of low-level laser therapy on women reporting pain and diagnosed with temporomandibular dysfunction (TMD). Methods: Diode laser (GaAlAs) at 790 nm wavelength (infrared spectrum) was applied as experimental treatment. Irradiations of 1.5 J/cm2 were made at 4 points of the temporomandibular joint (TMJ) and of 3 J/cm2 at 3 points in the temporal muscle. An electromyographic (EMG) evaluation of the masseter and anterior temporal was done at the following intervals: before, immediately after, 5 min and 20 min after laser application. Results: Comparison of the electrical activity at the times of measurement revealed a statistically significant difference in masseter muscles before (P=0.025) and immediately after (P=0.013) LLLT. Conclusions: Both masseter and temporal muscles showed a reduction in the measured EMG activities at all times after LLLT, and the temporal muscle showed higher EMG activity than the masseter muscle at all the evaluation times. LLLT caused significant immediate relaxation of the masseter muscles.
Resumo:
Objective To assess the diagnostic accuracy of the surface electromyography (sEMG) parameters associated with referred anterior knee pain in diagnosing patellofemoral pain syndrome (PFPS). Design Sensitivity and specificity analysis. Setting Physical rehabilitation center and laboratory of biomechanics and motor control. Participants Pain-free subjects (n=29) and participants with PFPS (n=22) selected by convenience. Interventions Not applicable. Main Outcome Measure The diagnostic accuracy was calculated for sEMG parameters’ reliability, precision, and ability to differentiate participants with and without PFPS. The selected sEMG parameter associated with anterior knee pain was considered as an index test and was compared with the reference standard for the diagnosis of PFPS. Intraclass correlation coefficient, SEM, independent t tests, sensitivity, specificity, negative and positive likelihood ratios, and negative and positive predictive values were used for the statistical analysis. Results The medium-frequency band (B2) parameter was reliable (intraclass correlation coefficient=.80–.90), precise (SEM=2.71–3.87 normalized unit), and able to differentiate participants with and without PFPS (P<.05). The association of B2 with anterior knee pain showed positive diagnostic accuracy values (specificity, .87; sensitivity, .70; negative likelihood ratio, .33; positive likelihood ratio, 5.63; negative predictive value, .72; and positive predictive value, .86). Conclusions The results provide evidence to support the use of EMG signals (B2 – frequency band of 45–96Hz) of the vastus lateralis and vastus medialis muscles with referred anterior knee pain in the diagnosis of PFPS.