12 resultados para Strength measurement

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tensile strength (TS) of soil aggregates is an important indicator of soil quality. However, TS varies with aggregate shape. Thus, the objective of this study was to quantify the influence of aggregate shape on TS and propose a shape standardization protocol to increase accuracy in the measurement of TS. The latter was determined on 7,560 aggregates divided into three shapes, (i) irregular shape (IS), (ii) spherical shape (SS), and (iii) flat surface (FS), while preserving the inherent structure of the aggregate. The aggregates with IS had a larger range in the TS (306 kPa) because of the shape variability when compared with SS (238 kPa) and FS (129 kPa). The TS determined in aggregates with FS had smaller coefficient of variation (46%) in comparison with those of IS (70%) and SS (66%), indicating that the aggregate uniformity reduced the influence of shape on the TS. A smaller force (42.12 kPa) was needed to rupture aggregates with FS than IS (58.43 kPa) and SS (56.89 kPa) because of better force distribution in causing the tensile stress. The use of aggregates with the FS enables an accurate assessment of TS in relation to a wide range of management treatments. Copyright © 2013 by Lippincott Williams & Wilkins.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE:To investigate the effects of alloxan diabetes on the abdominal wall healing of rats undergoing laparotomy.METHODS:Ninety-six male Wistar rats weighing between 200 and 300 grams, divided into two groups: non-diabetic group (G1) and another with untreated diabetes (G2). Three months after diabetes induction, the animals underwent a 5cm-long- laparotomy and 5.0 nylon monofilament suture. After the surgery, 12 animals from each group were euthanized on days 4, 14, 21 and 30 corresponding to the moments M1, M2, M3 and M4. In each moment a fragment of the abdominal wall containing the scar was removed for tensile strength measurement, histological and morphometric study. Clinical and biochemical parameters were also analyzed.RESULTS:G2 animals showed parameters compatible with severe diabetes and decreased plasma levels of insulin. The tensile strength in G2 was significantly smaller in M2 and M4, with a tendency to fall in the other two. Through light microscope, diabetic animals showed more difficulty to increase collagen density and contraction. G2 animals showed high cellularity of fibroblasts in later healing moments, with collagen thinning in M2 and M4.CONCLUSION:The abdominal wound healing in untreated diabetic animals was altered and led to a higher incidence of dehiscence and infections.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, the chemical structure, the microstructure and the surface morphology of two non-ferrous materials used in dental implants (Ti-6Al-4V and Co-Cr-Mo) were studied. This was done by chemical analysis, scanning electron microscopy (SEM), energy disperse spectroscopy (EDS), and strength measurements (HV). Metallographic studies reveal that titanium alloy surface present a fine granular binary phase structure, while cobalt alloy present cast dendrite structures with an intense precipitation of carbides. To correlate the macro and microstructure with the mechanical behavior of the material, microhardness measurements were performed. Using the Vickers hardening method, the Ti-6Al-4V alloy yielded strength mean values smaller than the Co-Cr-Mo alloy. Their values are associated to the chemical composition and to the microstructural distribution of these materials. The Ti-6Al-4V alloy presents hardness similar to dental enamel, which suggests better performance as dental implant.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Coactivation may be both desirable (injury prevention) or undesirable (strength measurement). In this context, different styles of muscle strength stimulus have being investigated. In this study we evaluated the effects of verbal and visual stimulation on rectus femoris and biceps femoris muscles contraction during isometric and concentric. Methods: We investigated 13 men (age =23.1 ± 3.8 years old; body mass =75.6 ± 9.1 kg; height =1.8 ± 0.07 m). We used the isokinetic dynamometer BIODEX device and an electromyographic (EMG) system. We evaluated the maximum isometric and isokinetic knee extension and flexion at 60°/s. The following conditions were evaluated: without visual nor verbal command (control); verbal command; visual command and; verbal and visual command. In relation to the concentric contraction, the volunteers performed five reciprocal and continuous contractions at 60°/s. With respect to isometric contractions it was made three contractions of five seconds for flexion and extension in a period of one minute. Results: We found that the peak torque during isometric flexion was higher in the subjects in the VVC condition (p > 0.05). In relation to muscle coactivation, the subjects presented higher values at the control condition (p > 0.05). Conclusion: We suggest that this type of stimulus is effective for the lower limbs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The serological detection of antibodies against human papillomavirus (HPV) antigens is a useful tool to determine exposure to genital HPV infection and in predicting the risk of infection persistence and associated lesions. Enzyme-linked immunosorbent assays (ELISAs) are commonly used for seroepidemiological studies of HPV infection but are not standardized. Intra-and interassay performance variation is difficult to control, especially in cohort studies that require the testing of specimens over extended periods. We propose the use of normalized absorbance ratios (NARs) as a standardization procedure to control for such variations and minimize measurement error. We compared NAR and ELISA optical density (OD) values for the strength of the correlation between serological results for paired visits 4 months apart and HPV-16 DNA positivity in cervical specimens from a cohort investigation of 2,048 women tested with an ELISA using HPV-16 virus-like particles. NARs were calculated by dividing the mean blank-subtracted (net) ODs by the equivalent values of a control serum pool included in the same plate in triplicate, using different dilutions. Stronger correlations were observed with NAR values than with net ODs at every dilution, with an overall reduction in nonexplained regression variability of 39%. Using logistic regression, the ranges of odds ratios of HPV-16 DNA positivity contrasting upper and lower quintiles at different dilutions and their averages were 4.73 to 5.47 for NARs and 2.78 to 3.28 for net ODs, with corresponding significant improvements in seroreactivity-risk trends across quintiles when NARs were used. The NAR standardization is a simple procedure to reduce measurement error in seroepidemiological studies of HPV infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is well known that fatigue behaviour is an important parameter to be considered in mechanical components subjected to constant and variable amplitude loadings. In combination with corrosion phenomenon, fatigue effects were responsible for proximally 64% of fails that occur in metallic parts of aeronautical accidents in the last 30 years. Recovered substrates have been extensively used in the aerospace field. Cadmium electroplating has been widely applied to promote protective coatings in aeronautical components, resulting in excellent corrosion protection combined with a good performance in cyclic loading. Ecological considerations allied to the increasing demands for corrosion resistance, resulted in the search for possible alternatives. Zinc-nickel alloys received considerable interest recently, since these coatings showed some advantages such as a good resistance to white and red rust, high plating rates and acceptation in the market. In this study the effects of zinc-nickel coatings electroplated on AISI 4340 high strength steel were analysed on rotating bending and axial fatigue strength, corrosion and adhesion resistance. Compressive residual stress field was measured by a X-ray tensometry prior to fatigue tests. Optical microscopy images showed coating thicknesses, adhesion and the existence of an uniform coverage of nearly all substrates. The fractured fatigue specimens were investigated using a scanning electron microscope. Three different zinc-nickel coating thicknesses were tested and comparison with rotating bending fatigue data from specimens cadmium electroplated and heat treated at 190°C for 3, 8 and 24 hours to avoid the diffusion of hydrogen in the substrate, was performed. Experimental results showed effect of coatings on the AISI 4340 steel behaviour when submitted to fatigue testing and the existence of coating thickness influence on the fatigue strength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods: Metallic frameworks (25 mm × 3 mm × 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 μm aluminum oxide at the central area of the frameworks (8 mm × 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: 1 mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 °C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 °C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 °C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey's test (α = 0.05). Results: The mean flexural strength values for the ceramic-gold alloy combination (55 ± 7.2 MPa) were significantly higher than those of the ceramic-Ti cp combination (32 ± 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 ± 6.6 and 53 ± 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 ± 6.8 and 29 ± 6.8 MPa, respectively) compared to the control group (58 ± 7.8 and 39 ± 5.1 MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey's test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance: Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. © 2007 Academy of Dental Materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To verify the effects of resistance training at the electromyographic fatigue threshold (EMGFT) based on one-repetition maximum strength (1RM), heart rate (HR), rate of perceived exertion (PE) and endurance time (EndT). Methods. Nineteen subjects (training group [TG]: n = 10; control group [CG]: n = 9), performed 1-min bicep curl exercises sets at 25%, 30%, 35% and 40% 1RM. Electromyography (biceps brachii and brachiorradialis), HR and PE were registered. Biceps brachii EMGFT was used to create a load index for an eight-week resistance training programme (three sets until exhaustion/session, two sessions/week) for the TG. The CG only attended one session in the first week and another session in the last week of the eight-week training period for EndT measurement. EndT was determined from the number of repetitions of each of the three sets performed in the first and last training sessions. After training, 1RM, EMGFT, EndT, HR and PE at the different bicep curl load intensities were again measured for both groups. Results. Increases in 1RM (5.9%, p < 0.05) and EndT (> 60%, p < 0.001) after training were found. In addition, PE was reduced at all load intensities (p < 0.05), while no changes were found for HR and EMGFT after training. Conclusions. Strength-endurance training based on the EMGFT improved muscular endurance and also, to a lesser extent, muscular strength. Moreover, the reduced levels of physical exertion after training at the same intensity suggest that endurance training exercises may improve comfort while performing strength exercises.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)