20 resultados para Storage tanks.
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
A mathematical model was developed in order to study the behavior of thermal stratification of liquid in a typical storage tank with porous medium. The model employs a transient stream function-vorticity formulation to predict the development of stream function and temperature fields in a charging process. Parameters analyzed include Biot, Darcy, Reynolds and Richardson numbers, position, and the thickness of the porous medium. The results show the influence of these physical parameters that should be considered for a good design of storage tanks with thermal stratification.
Resumo:
We present the results of a comparative study on thermally stratified tanks for hot storage. A two-dimensional model is employed. A numerical solution was obtained using the control-volume technique due to Patankar. The two-dimensional model was simplified for the pure conduction case. Results from the two models were compared with each other and with available numerical and experimental results. (C) 1997 Elsevier B.V. Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Em experimento de campo, avaliou-se o potencial de impacto ambiental de águas residuárias de suinocultura, acondicionadas em um tanque de estocagem, com distintos tempos de retenção hidráulica e aplicadas, posteriormente, em lisímetros preenchidos com solos arenosos, argilosos e de texturas médias. Para tal, foram determinados os valores de pH nos solos e as quantificações das concentrações de zinco e cobre na água residuária in natura e, após os quatro tempos de retenção hidráulica do tanque de estocagem, nos percolados dos lisímetros e nos solos. Os resultados mostram que a estocagem não foi eficiente na redução, aos níveis exigidos pela legislação, das concentrações de zinco e cobre nos efluentes do tanque de estocagem. A aplicação no solo gerou reduções eficientes nas concentrações de zinco e cobre. Por fim, enfocando a contribuição fertilizante destas águas residuárias, o solo argiloso foi o mais beneficiado com este sistema integrado de tratamento, contribuindo para a redução das concentrações de zinco e cobre para valores abaixo dos permitidos pelas legislações, o que protegeria o lençol freático da contaminação por esses dois metais pesados.
Resumo:
Objective. To assess the potential for contamination of wastewaters from pig farming. Methods. Wastewaters from pig farming were stored in a tank. After 0, 30, 60, 90, and 120 days of hydraulic retention, they were added to lysimeters filled with argillaceous, sandy, or medium soil. Finally, these lysimeters were submitted to simulations of either a rainy season or a dry season. The number of colony-forming units (CFUs) of total coliforms, fecal coliforms, and fecal streptococci was measured in the effluents of the storage tank (for the various periods of hydraulic retention), in the percolate from the lysimeters, and in the three types of soil. The microbiological analyses were carried out using the membrane filter technique. The pH analyses were done potentiometrically. Results. For the three microorganisms, the largest decrease in bacterial counts in the storage tanks occurred with 90 or 120 days of retention. There was a marked decrease in the bacterial count in the percolates of the three soils. For the three soil types the greatest reduction in bacterial counts was found in medium soil, due to its acidity (pH < 7.0). Hydraulic retention was not sufficient to ensure the sanitary adequacy of the wastewaters and their use for irrigation, given that fecal coliform values were above 1 000 CFU per 100 mL. Therefore, adding the residues to the soil was considered a second stage of treatment. Conclusions. The retention of wastewaters followed by adding them to soil was effective in minimizing the contaminating effect of pig farming residues. The storage time for wastewaters from pig farming could be decreased from 120 to 90 days.
Resumo:
An experimental apparatus containing a domestic refrigerator coupled to a vertical hot water storage tank was used for energy recovery. The original condenser of the refrigerator was maintained, but modified with a concentric tubes heat exchanger with countercurrent water and refrigerating gas flows. The coefficient of performance for the heat pump is calculated by the ratio of energy in the heat storage and the electric power consumed by the domestic refrigerator compressor. The results show that the increasing of hydrostatic pressure in the storage tank increases the water flow rate and the coefficient of performance. The proposed device also reduces the heat dissipation to the surroundings. This is more important in small confinements found in low-cost houses.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
We studied the molecular epidemiology of Staphylococcus aureus strains potentially toxigenic, isolated from the production process of Minas frescal cheese in a small dairy plant in the state of São Paulo. For this, samples were taken during the period from June 2008 to July 2009. Samples were collected from the surface of the receiving and storage tanks of raw milk, the surface of the balance tank of pasteurized milk, the water supply system, the pipes and equipments, the hands of the handler and from the packaged cheese, totaling 140 samples. The colonies isolated on Baird-Parker Agar confirmed as Gram positive and positive for catalase, coagulase and acetoin production, were submitted to extraction of bacterial DNA using the Invitek - Uniscience® kit. Confirmation of the isolated species and enterotoxins SEA, SEB, SEC, SED and TSST-1 toxin was carried out through the amplification of specific fragments of chromosomal DNA. Among the 74 strains of isolated coagulase-positive staphylococci, only 41 (55.4%) strains were confirmed as Staphylococcus aureus, of which 25 (61.0%) were positive to the presence of staphylococcal toxins. The most frequently identified enterotoxin was SEA. The toxigenic strains of Staphylococcus aureus were more frequently isolated from hands of the handler (16.0%), raw milk receiving tank (12.0%), pasteurized milk for cheese making (12.0%) and fresh white cheese ready for consumption (12.0%).
Resumo:
High-density polyethylene (HDPE) water-proof membranes are used as coatings in vinasse (leachate from sugar cane) storage tanks. The leachate is pumped into the tanks at temperatures of 80-90 °C. Due to these high temperatures and acidity of the waste, these membranes can be degraded, cracked and then loose the function for which they have been designed. This may cause contamination of the soil and groundwater. This study evaluated the effect of vinasse in HDPE membranes after 4 months of exposure in a controlled environment. An aggressive, alkaline pH liquid (sodium hydroxide) was also used. The objective was to evaluate the membrane resistance in contact with acidic and alkaline residues. Physical and mechanical tests, measurement of the carbon black content and thermo gravimetric analysis (TGA) were used to determine degradation of polymer membranes after chemical immersion. While sodium hydroxide resulted caused only minor changes in the physical properties, vinasse induced a thickness change of 7.8%. With immersion in vinasse, an average decrease in strength and deformability (yield) of 34% and 23.5% were measured, respectively. The stiffness increased by 7.8% (average) and the tear strength decreased by 2.7% (average).
Resumo:
The contamination of underground waters is a subject of great importance, since a lot of people use this kind of source for public supply. This paperwork manages with how gas stations can contaminate these waters and what are some remediation techniques, used nowadays to solve this problem. The contamination caused by the gas stations can have its origin in the underground storage tanks when they suffer corrosion and show leaking problems. It’s a topic of great relevance, because the hydrocarbons derivated from petroleum present in the fuels can stay for a long time in the environment. Besides that, an analyses of the risk of contamination by gas stations in the city of Rio Claro was made based on three parameters: density of the gas stations, depth of the underground water and hydraulic conductivity. To achieve such goal, maps were elaborated considering those parameters individually and considering the three of them together. Analyzing those maps, it was concluded see that the spots that represent the biggest risks of contamination in Rio Claro are located southeast and center-west.
Resumo:
Leaking of hydrocarbon in fuel underground storage tanks constitute object of concern for urban environmental management, because therefore they provoke damages to the physical, biological and socioeconomic environment. Though laws that regulate this essential activity exist, aiming at to prevent contamination with hydrocarbon, we observe that this still happens. This fact evidences that the selection of places for installation of gas stations has not considered the characteristics of the natural environment, implying in more critical consequences associated to the leaking. The objective of this work is to elaborate a chart applied to the gas stations in Rio Claro/SP. The determination of the Index of Environmental Sensitivity for elaboration of such chart was carried through breaking the selection of factors of Environmental Sensitivity of physical, biological and socioeconomic environment. The balance of these factors was given by means of Ad hoc consultation. The crossing of the information was carried through using the method of overlapping of overlays. The result is a chart that shows us areas with classes of high, middle and low Environmental Sensitivity. One gives credit that this type of material can be used as criterion in the selection of adjusted areas for installations of new gas stations and management of the already installed gas stations. The diagnosis of the current situation of the gas stations in the area and recommendations had also been elaborated.