16 resultados para Static conditions

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The operational details of the apparent electrical conductivity (ECa) sensor manufactured by Veris Technologies have been extensively documented in literature reports, but the geographical distribution of these research studies indicate a strong regional concentration in the US Mid-west and Southern states. The agricultural lands of these states diverge significantly to the soil conditions and water regime of irrigated land in the US South-western states such as Arizona where there is no previous research reports of the use of this particular sensor. The objectives of the present study were to analyze the performance of this sensor under the conditions of typical soils in irrigated farms of Central Arizona. We tested under static conditions the performance of the sensor on three soils of contrasting texture. Observations were collected as time series data as soil moisture changed from saturation to permanent wilting point. Observations were repeated at the hours of lowest and highest temperatures. In addition, this study included soil penetration resistance and salinity determinations. Preliminary results indicate that soil temperature of the upper layer caused the most dynamic change in the sensor output. The ECa curves of the three soil textures tested had well defined distinctive characteristics. Final multivariate analysis is pending.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gurjao, ALD, Goncalves, R, de Moura, RF, and Gobbi, S. Acute effect of static stretching on rate of force development and maximal voluntary contraction in older women. J Strength Cond Res 23(7): 2149-2154, 2009-The purpose of this study was to investigate, in older women, the acute effect of static stretching (SS) on both muscle activation and force output. Twenty-three older women (64.6 +/- 7.1 yr) participated in the study. The maximal voluntary contraction (MVC), rate of force development (RFD) (50, 100, 150, and 200 ms relative to onset of muscular contraction), and peak RFD (PRFD) (the steepest slope of the curve during the first 200 ms) were tested under 2 randomly separate conditions: SS and control (C). Electromyographic (EMG) activity of the vastus medialis (VM), vastus lateralis (VL), and biceps femoris (BF) muscles also was assessed. The MVC was significantly lower (p < 0.05) in the 3 trials of SS when compared with the C condition (control: 925.0 +/- 50.9 N; trial 1 : 854.3 +/- 55.3 N; trial 2 : 863.1 +/- 52.2 N; and trial 3 : 877.5 +/- 49.9 N). PRFD showed a significant decrease only for the first 2 trials of SS when compared with the C condition (control: 2672.3 +/- 259.1 N/s; trial 1 : 2296.6 +/- 300.7 N/s; and trial 2 : 2197.9 +/- 246.3 N/s). However, no difference was found for RFD (50, 100, 150, and 200 ms relative to onset of muscular contraction). The EMG activity for VM, VL, and BF was not significantly different between the C and SS conditions. In conclusion, the older women's capacity to produce muscular force decreased after their performance of SS exercises. The mechanisms responsible for this effect do not appear to be related to muscle activation. Thus, if flexibility is to be trained, it is recommended that SS does not occur just before the performance of activities that require high levels of muscular force.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to assess the effect of the use of high-heeled shoes on static balance in young adult women. Fifty-three women between 18 and 30 years of age and accustomed to wearing high-heeled shoes participated in the study. None of the participants had any orthopedic or neurologic alterations. Static balance was assessed using a force plate. Oscillations from the center of pressure in the mediolateral and anteroposterior directions were measured both when barefoot and when wearing high-heeled shoes [7 centimeters (cm) in height and 1 cm in diameter] under the conditions of eyes open and eyes closed. Two-way analysis of variance was employed for the statistical analysis, with the level of significance set at 5% (p < .05). The results revealed statistically significant differences between tests when barefoot and when wearing high-heeled shoes as well as with eyes open and eyes closed (p < .01). With the use of high-heeled shoes, there was a significant increase in mediolateral oscillation with eyes closed (p < .01). The present study demonstrates that the use of seven-cm high heels altered static balance in the healthy young women analyzed, increasing the oscillation of the center of pressure, regardless of visual restriction. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Some factors influencing the growth and production of extracellular lipase by Rhizopus oligosporus were studied. Highest yields of enzyme were obtained when Tweens were the carbon source. Soybean meal extract supported good growth and enzyme production. Carbohydrates, vegetable oils, proteins or amino acids did not stimulate lipase production. The fungus grew well with carbohydrate- or protein-supplemented media but not with oils, unless emulsified with a non-metabolizable gum. The production of biomass in static cultures was maximum at 35-40°C after 4 d at pH 5.5. The yield of lipase was maximum at 25°C after 3 d at pH 6.5. Shaking cultures enhanced growth but decreased lipase production.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Teaching a course of special electric loads in a continuing education program to power engineers is a difficult task because they are not familiarized with switching topology circuits. Normally, in a typical program, many hours are dedicated to explain the thyristors switching sequence and to draw the converter currents and terminal voltages waveforms for different operative conditions. This work presents teaching support software in order to optimize the time spent in this task and, mainly to benefit the assimilation of the proposed subjects, studying the static converter under different non-ideal operative conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. The purpose of this study was to analyze the influence of gender on the adaptive locomotion in the clearance of obstacles. Specifically, it was evaluated if there are differences in the space-temporal parameters between male and female in the clearance of and dynamic obstacles moving at both slow and fast speeds. Basic procedures. Five young male adults and five young female adults took part in this study. The task was performed in three conditions: static obstacle and dynamic obstacle - clearance perpendicular to the participant's trajectory at slow speed (1.07 m/s) and at fast speed (1.71 m/s). The trials were recorded by two digital cameras and spatial-temporal information was obtained. Main findings. The dynamic obstacle conditions required more visual inspection. The results showed different adaptive locomotion between the sexes. The distinct gait patterns were evidenced for the spatial and temporal variables and cadence in the three conditions. Conclusions. The women presented a more conservative behavior, which was evidenced by the increase of the length in the penultimate step and in the toe clearance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.