141 resultados para Speed and torque observers
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Relaxed conditions for stability of nonlinear, continuous and discrete-time systems given by fuzzy models are presented. A theoretical analysis shows that the proposed methods provide better or at least the same results of the methods presented in the literature. Numerical results exemplify this fact. These results are also used for fuzzy regulators and observers designs. The nonlinear systems are represented by fuzzy models proposed by Takagi and Sugeno. The stability analysis and the design of controllers are described by linear matrix inequalities, that can be solved efficiently using convex programming techniques. The specification of the decay rate, constrains on control input and output are also discussed.
Resumo:
Tegtbur et al. [23] devised a new method able to estimate the intensity at maximal lactate steady state termed lactate minimum test. According to Billat et al. [7], no studies have yet been published on the affect of training on highest blood lactate concentration that can be maintained over time without continual blood lactate accumulation. Therefore, the aim of the present study was to verify the effect of soccer training on the running speed and the blood lactate concentration (BLC) at the lactate minimum test (Lac(min)). Thirteen Brazilian male professional soccer players, all members of the same team playing at National level, volunteered for this study. Measurements were carried out before (pre) and after (post) eight weeks of soccer training. The Lac(min) test was adapted to the procedures reported by Tegtbur et al. [23]. The running speed at the Lac(min) test was taken when the gradient of the line was zero. Differences in running speed and blood lactate concentration at the Lac(min) test before (pre) and after (post) the training program were evaluated by Student's paired t-test. The training program increased the running speed at the Lac(min) test (14.94 +/- 0.21 vs. 15.44 +/- 0.42* km(.)h(-1)) and the blood lactate concentration (5.11 +/- 2.31 vs. 6.93 +/- 1.33* mmol(.)L(-1)). The enhance in the blood lactate concentration may be explained by an increase in the lactate/H+ transport capacity of human skeletal muscle verified by other authors.
Resumo:
Purpose: This study evaluated the effect of cutting initiation location and cutting speed on the bond strength between resin cement and feldspathic ceramic.Materials and Methods: Thirty-six blocks (6.4 x 6.4 x 4.8 mm) of ceramic (Vita VM7) were produced. The ceramic surfaces were etched with 10% hydrofluoric acid gel for 60 s and then silanized. Each ceramic block was placed in a silicon mold with the treated surface exposed. A resin cement (Variolink II) was injected into the mold over the treated surface and polymerized. The resin cement-ceramic blocks were divided into two groups according to experimental conditions: a) cutting initiation location - resin cement, ceramic and interface; and b) cutting speed - 10,000, 15,000, and 20,000 rpm. The blocks were sectioned to achieve non-trimmed bar specimens. The microtensile test was performed in a universal testing machine (1 mm/min). The failure modes were examined using an optical light microscope and SEM. Bond strength results were analyzed using one-way ANOVA and Tukey's test (alpha = 0.05).Results: Significant influences of cutting speed and initiation location on bond strength (p < 0.05) were observed. The highest mean was achieved for specimens cut at 15,000 rpm at the interface (15.12 +/- 5.36 MPa). The lowest means were obtained for specimens cut at the highest cutting speed in resin cement (8.50 +/- 3.27 MPa), and cut at the lowest cutting speed in ceramic (8.60 +/- 2.65MPa). All groups showed mainly mixed failure (75% to 100%).Conclusion: The cutting speed and initiation location are important factors that should be considered during specimen preparation for microtensile bond strength testing, as both may influence the bond strength results.
Resumo:
The purpose of this study was to evaluate the effect of using different mathematical models to describe the relationship between treadmill running speed and time to exhaustion. All models generated a value for an aerobic parameter (critical speed; S(critical)). 35 university students performed 5-7 constant-speed 0%-slope treadmill tests at speeds that elicited exhaustion in similar to 3 min to similar to 10 min. Speed and time data were fitted using 3 models: (1) a 2-parameter hyperbolic model; (2) a 3-parameter hyperbolic model; and (3) a hybrid 3-parameter hyperbolic + exponential model. The 2-parameter model generated values for S(critical) (mean (+/- SD): 186 +/- 33 m.min(-1)) and anaerobic distance capacity (ADC; 251 +/- 122 m) with a high level of statistical certainty (i.e., with small SEEs). The 3-parameter models generated parameter estimates that were unrealistic in magnitude and/or associated with large SEEs and little statistical certainty. Therefore, it was concluded that, for the range of exercise durations used in the present study, the 2-parameter model is preferred because it provides a parsimonious description of the relationship between velocity and time to fatigue, and it produces parameters of known physiological significance, with excellent confidence.
Resumo:
This study analyzed the relationship between critical speed (CS) and maximal speed for 30 min (S30) in swimmers of ages 10-15 years. Fifty-one swimmers were divided by chronological age (10-12 years = G10-12, 13-15 years = G13-15), sexual maturation (pubic hair stages; P1-P3 and P4-P5), and gender (M = boys, F = girls). The CS was determined through the slope of the linear regression between the distances (100, 200, and 400 m) and participants' respective times. CS and S30 were similar in the younger (G10-12M = 0.97 vs. 0.97 m/s, and G10-12F = 1.01 vs. 0.97 m/s, respectively), and older swimmers (G13-15M = 1.10 vs. 1.07 m/s and G13-15F = 0.93 vs. 0.91 m/s, respectively). In conclusion, the CS can be used in young swimmers for the evaluation of aerobic capacity, independent of gender and age. © 2005 Human Kinetics, Inc.
Resumo:
Our objective was to analyze the effect of gender on the relationship between stroke rates corresponding to critical speed (SRCS) and maximal speed of 30 min (SRS30) in young swimmers. Twenty two males (GM1) (Age = 15.4 ± 2.1 yr., Body mass = 63.7 ± 12.9 kg, Stature = 1.73 ± 0.09 m) and fourteen female (GF) swimmers (Age = 15.1 ± 1.6 yr., Body mass = 58.3 ± 8.8 kg, Stature = 1.65 ± 0.06 m) were studied. A subset of males (GM2) was matched to the GF by their velocity for a 30 min swim (S30). The critical speed (CS) was determined through the slope of the linear regression line between the distances (200 and 400 m) and participant's respective times. CS was significantly higher than S30 in males (GM1 - 1.25 and 1.16 and GM2 - 1.21 and 1.12 m·s-1) and females (GF - 1.15 and 1.11 m·s-1). There was no significant difference between SRCS and SRS30 in males (GM1 - 34.16 and 32.32 and GM2 - 34.67 and 32.46 cycle·s-1, respectively) and females (GF - 34.18 and 33.67 cycle·s-1-1, respectively). There was a significant correlation between CS and S30 (GM1 - r = 0.89, GF - r = 0.94 and GM2 - r = 0.90) and between SRCS and SRS30 (GM1 - r = 0.89, GF - r = 0.80 and GM2 - r = 0.88). Thus, the relationship between SRCS and SRS30 is not influenced by gender, in swimmers with similar and different aerobic capacity levels. ©Journal of Sports Science and Medicine (2007).
Resumo:
AIM: To compare five different protocols for estimating the lactate minimum speed (LMS) with that for estimating the maximal lactate steady state (MLSS) in Arabian horses, in order to obtain a more rapid method for monitoring aerobic capacity and prescribing training schedules. METHODS: Eight purebred Arabian horses were conditioned to exercise on a treadmill for 12 days then submitted to three to five exercise sessions to determine the MLSS. Blood samples were collected from a jugular catheter at specific intervals for measurement of lactate concentrations. The MLSS was the velocity maintained during the last 20 minutes of constant submaximal exercise, at which the concentration of lactate increased by no more than 1.0 mmol/L. The LMS test protocols (P1 - P5) included a warm-up period followed by a high-intensity gallop. The speed was then reduced to 4 m/s, and the incremental portion of the test was initiated. In P1, P2, and P3, the velocity increment was 0.5 m/s, and the duration of each incremental stage was three, five and seven minutes, respectively. In P4 and P5, the velocity increments were 1.0 and 1.5 m/s, respectively, and the duration of the stages was fixed at five minutes each. A second-degree polynomial function was fitted to the lactate-velocity curve, and the velocity corresponding to the lowest concentration of lactate was the LMS. RESULTS: Only the mean LMS determined by P1 and P2 did not differ from the velocity determined by the MLSS test (p > 0.1). There was a strong correlation (r >0.6) between P1 and the MLSS velocity. A limits of agreement plot revealed that the best agreement occurred between the MLSS test and P1 (mean bias = 0.14 m/s), followed by P2 (bias = -0.22 m/s). The lactate concentrations associated with the various LMS protocols did not differ. CONCLUSIONS: This study shows the variation between protocols of the LMS test for determining the onset of blood lactate accumulation but also reveals that, at least for Arabian horses, the P1 protocol of the LMS has good agreement with the MLSS. © 2013 Copyright New Zealand Veterinary Association.
Resumo:
O desempenho de tratores agrícolas em condições de campo resulta da interação entre pneu e rodado, influenciado pela velocidade de deslocamento. O objetivo deste trabalho foi avaliar o desempenho de um trator agrícola sob diferentes pressões de inflação dos pneus da semeadora (518, 483, and 414kPa) e em duas marchas que proporcionaram velocidades de 3,0 e 6,0km h-1. O experimento foi realizado no campus de Jaboticabal da Universidade Estadual Paulista (UNESP). O delineamento experimental utilizado foi fatorial inteiramente casualizado (3x2), com quatro repetições. A força de tração foi influenciada pela marcha e pela potência exigida; no entanto, a pressão de inflação do pneu da semeadora não alterou esses parâmetros. Além disso, o consumo de combustível foi influenciado apenas pela marcha do trator. O consumo de energia foi maior com o aumento da velocidade, ocasionada pela mudança de marcha. A velocidade de deslocamento foi maior para a pressão de 518kPa, em razão da menor patinagem da semeadora promovida por essa pressão. A patinagem do trator não foi alterada pelos fatores testados.
Onset of quadriceps and torque variation in individuals with patellofemoral pain during stair ascent
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective The aim of this study was to compare intrapulpal temperature increases produced by a high-speed high-torque (speed-increasing) handpiece, a high-speed low-torque handpiece (air-turbine) and an Er: YAG (Erbium: Yttrium-Aluminum-Garnet) laser. Subject and methods Thirty bovine incisors were reduced to a dentine thickness of 2.0 mm. Class V preparations were prepared to a depth of 1.5 mm, measured with a caliper or by a mark on the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (C). Analysis was performed on the following groups (n = 10) treated with: G1, low-torque handpiece; G2, high-torque handpiece; and G3, Er: YAG laser (2.94 mu m at 250 mJ/4 Hz), all with water cooling. The temperature increases were recorded with a computer linked to the thermocouples. Results The data were submitted to ANOVA and Tukey statistical test. The average temperature rises were: 1.92 +/- 0.80 degrees C for G1, 1.34 +/- 0.86 degrees C for G2, and 0.75 +/- 0.39 degrees C for G3. There were significant statistical differences among the groups (p = 0.095). All the groups tested did not have a change of temperature that exceeds the threshold of 5.5 degrees C. Conclusion Temperature response to the low and high torque handpieces seemed to be similar, however the Er: YAG laser generated a lower temperature rise.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Statement of problem. During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis.Purpose. The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser.Material and methods. Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark oil the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degreesC). Analysis was performed on the following groups (n = 10): Group 1, high-speed handpiece without water cooling, Group 11, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 mum at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha = .05).Results. The average temperature rises were: 11.64degreesC (+/-4.35) for Group 1, 0.96degreesC (+/-0.71) for Group 11, and 2.69degreesC (+/-1.12) for Group III. There were no statistical differences between Groups 11 and III, both 11 and III differed from Group I significantly (P = .000 and P = .002, respectively).Conclusion. The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser.
Resumo:
An analytical approach for the spin stabilized satellite attitude propagation is presented using the non-singular canonical variables to describe the rotational motion. Two sets of variables were introduced for Fukushima in 1994 by a canonical transformation and they are useful when the angle between z-satellite axis of a coordinate system fixed in artificial satellite and the rotational angular momentum vector is zero or when the angle between Z-equatorial axis and rotation angular momentum vector is zero. Analytical solutions for rotational motion equations and torque-free motion are discussed in terms of the elliptic functions and by the application of some simplification to get an approximated solution. These solutions are compared with a numerical solution and the results show a good agreement for many rotation periods. When the mean Hamiltonian associated with the gravity gradient torque is included, an analytical solution is obtained by the application of the successive approximations' method for the satellite in an elliptical orbit. These solutions show that the magnitude of the rotation angular moment is not affected by the gravity gradient torque but this torque causes linear and periodic variations in the angular variables, long and short periodic variations in Z-equatorial component of the rotation angular moment and short periodic variations in x-satellite component of the rotation angular moment. The goal of this analysis is to emphasize the geometrical and physical meaning of the non-singular variables and to validate the approximated analytical solution for the rotational motion without elliptic functions for a non-symmetrical satellite. The analysis can be applied for spin stabilized satellite and in this case the general solution and the approximated solution are coincidence. Then the results can be used in analysis of the space mission of the Brazilian Satellites. (C) 2007 COSPAR. Published by Elsevier Ltd. All rights reserved.