This work describes a methodology developed for determination of costs associated to products generated in a small wastewater treatment station for sanitary wastewater from a university campus. This methodology begins with plant component units identification, relating their fluid and thermodynamics features for each point marked in its process diagram. Following, its functional diagram is developed and its formulation is elaborated, in exergetic base, describing all equations for these points, which are the constraints for exergetic production cost problem and are used in equations to determine the costs associated to products generated in SWTS. This methodology was applied to a hypothetical system based on SWTS former parts and presented consistent results when compared to expected values based on previous exergetic expertise. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The possibility of thermal treatment plants of municipal wastewater is an alternative solution for the final disposition of the sludge produced on small cities as Barueri, a small town of São Paulo State, Brazil. Combustion and pyrolysis of that municipal waste, occurring respectively in air and nitrogen, have been studied by thermogravimetry (TG) and differential thermal analysis (DTA). The main steps of each case were analyzed and Kissinger plots were used to estimate respective activation energies. DTG peaks are more indicated to represent the condition of maximum reaction rates than DTA peaks.
Resumo:
The good efficiency in a sewage treatment plant (WWTP) is a great importance to the environment. The management of electromechanical equipment installed in these stations is a major challenge due to the fact that they are installed on areas of difficult access and maintenance unhealthy and making the time for the correction of any faults is extended. This paper proposes the development of a Wireless Sensor Network (WSN), in order to monitor electromechanical equipment, allowing the Concessionaire a predictive control in real time. The design of a wireless sensors network for monitoring equipment requires not only the development and assembly of the sensor modules, but must also include the development of software for managing the data collected. Thus, this work includes a Zigbee WSN, small, adapted for monitoring of electromechanical equipment and environmental conditions of a WWTP, type stabilization pond, installed in an area of approximately 0.15 km 2 and the average flow of 320 liters of treatment per second. The experimental results show that this monitoring system can perform with the collection of parameters of performance and quality assessment at the station.
Resumo:
The number of the cities with canalized water and sewage treatment stations has increased lately and consequently having in mind the great concern on environment preservation and the quality of the water used by society. However, these stations are nowadays causing another kind of problem: a huge quantity of sludge as residue. Due to the implication of the residue on the environment and, consequently, to human life quality, performing of an accurate investigation about the components of such sludge, as well as the thermal stability of this residue in the environment become necessary. This paper presents a study on sludge from water and sewage treatment station, as well as the thermal characterization of residue. Such study was performed through FTIR, atomic absorption, thermoanalytical (TG/DTG, DTA) techniques, that made it possible to observe that the main components of the sludge are clay, carbonates and organic substance, presenting a low rate of metals and a unique thermal behavior since the sludge from the treatment station has a higher thermal stability.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Physical and chemical variables of soil and water were measured to determine the effectiveness of a constructed wetland for wastewater treatment. Eight different macrophyte species, namely Eichhornia crassipes, Alternanthera philoxerodos, Heteranthera reniformis, Hydrocotyle umbeliferae, Lidwigia elegan, Ludwigia sericea, Myriophyllum aquaticum and Thypha domingensis, were transplanted. Inlet water and outlet water were the two sampling sites evaluated. There were significant differences (p < 0,05) when limnological characteristics between inlet and outlet water from the constructed wetland were compared. In general, dissolved oxygen was over 4 mg L-1, and conductivity was high, above 80 μS cm-1. Chlorophyll-a levels generally tended to decrease at the wetland outlet and were higher during the rainy period (fish growth period). Results show that ammonia, total phosphorus, BOD5, phosphorus and organic mattel in the sediment removals in the constructed wetland were higher, indicating that macrophytes played an important role in removing these variables. The use of constructed wetland is a viable technology for the biological treatment in aquaculture and swine wastewater.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The imposition of more stringent legislation by CETESB in the State of So Paulo (Brazil) governing the disposal and utilization of sewage sludge, coupled with the growth in its generation has prompted a drive for alternative uses of sewage sludge. One option that is especially promising, due to its potential to valorize sludge, is its conversion into carbonaceous adsorbents or coke for industrial effluents treatment. Thus, a methodology is presented to estimate the coke produced from the sludge of a sewage treatment station using thermal analysis. The used sewage sludge, which comes from aerobic treatment, was collected in the wastewater treatment station of Barueri, one of the largest of the So Paulo metropolitan area. The sludge samples were collected, dried, ground, and milled until they passed an ABNT 200 sieve. The inert ambient used during its thermal treatment produces inorganic matter and coke as residual materials. Coke formation occurs in the 200-500 A degrees C range and, between 500 and 900 A degrees C, its thermal decomposition occurs. The highest formation of coke occurs at 500 A degrees C.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The red Fe2+-phenanthroline complex is the basis of a classical spectrophotometric method for determination of iron. Due to the toxicity of this complexing agent, direct disposal of the wastewaters generated in analytical laboratories is not environmentally safe. This work evaluates the use of the solar photo-Fenton process for the treatment of laboratory wastewaters containing phenanthroline. Firstly, the degradation of phenanthroline in water was evaluated at two concentration levels (0.1 and 0.01%, w/v) and the efficiencies of degradation using ferrioxalate (FeOx) and ferric nitrate were compared. The 0.01% w/v solution presented much higher mineralization, achieving 82% after 30 min of solar irradiation with both iron sources. The solar photo-Fenton treatment of laboratory wastewater containing, in addition to phenanthroline, other organic compounds such as herbicides and 4-chlorophenol, equivalent to 4500 mg L-1 total organic carbon (TOC) resulted in total degradation of phenanthroline and 25% TOC removal after 150 min, in the presence of either FeOx or ferric nitrate. A ratio of 1: 10 dilution of the residue increased mineralization in the presence of ferrioxalate, achieving 38% TOC removal after 120 min, while use of ferric nitrate resulted in only 6% mineralization over the same period. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
A viability study of an electrolytic process for the transformation of organic matter and free sulphide contained in wastewater from a fowl slaughterhouse in order to minimise odours was carried out Cast iron and aluminium electrodes were tried at 7.09 mA/cm2, under strong agitation, at 297 K. Conductivity, pH, chemical oxygen demand (COD), amount of settleable solids, and sulphide content were monitored with electrolysis duration. The cast iron electrodes were found to be viable for the elimination of soluble sulphides in the wastewater, leading to the elimination of its strong odour after short times of electrolysis. A significant decrease in COD was also attained.