19 resultados para Small Scale Industries

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The description of the small-scale fisheries in the middle River Tocantins and their dynamics, in a full year cycle, was made out using questionnaires when interviewing fishermen at Imperatriz market. The landed fish exhibited a seasonal pattern related to the hydrological cycle, fishing effort and species diversity. Curimata, Prochilodus nigricans Agassiz, is the most important commercial fish. The fishing gears used in the area are castnets, gillnets, longlines and beach seines. Thirty-six percent of fish landed were caught exclusively by beach seine which mainly targets curimata. Alterations in the physical and biological characteristics of the middle River Tocantins due to the building of the Tucurui dam (2850 km(2) total area) allowed the mapara, Hipophthalmus marginatus Valenciennes, to colonise this area. During the closed season for nets, Siluriformes are the target of the fisheries, caught exclusively by longlining.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Herbicidas tais como trifluralina, simazina, atrazina, metribuzina e metolaclor são usados na agricultura brasileira. A eficiência de um método em pequena escala para a determinação destes herbicidas e dois produtos de degradação em amostras de solo foi avaliada. Os compostos foram extraídos das amostras de solo (5 g) com 20 ml de acetato de etila em agitador mecânico por 50 min. Após a extração, o sobrenadante foi filtrado em sulfato de sódio anidro, concentrado e analisado por cromatografia a gás de alta resolução com detector termiônico específico. Valores médios de recuperação obtidos de amostras de solo fortificadas em três níveis diferentes variaram de 81 a 115 % com valores de desvio padrão relativo entre 1,2 e 12,7 %. Os limites de detecção do método variaram de 0,01 a 0,06 mg kg-1. A metodologia foi aplicada a amostras de solo de fazendas localizadas próximas à cidade de Araraquara, estado de São Paulo, Brasil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A small-scale method was developed for the simultaneous determination of γ-HCH, heptachlor, aldrin, dicofol, mirex, endosulfan I, endosulfan II and endosulfan sulphate in soil. The extraction and clean-up steps were combined into one step by transferring soil samples to chromatographic columns prepacked with neutral alumina. The pesticides elution was processed with n-hexane : dichloromethane (7:3) and the concentrated eluate was analysed using gas-liquid chromatography with electron capture detection. Analyses of the in vitro fortified samples with the selected pesticides were performed at three different levels. Mean recoveries for aldrin, γ-HCH and heptachlor, at levels of 2, 10 and 20 ng/g, ranged from 71 to 87%; for dicofol, at levels of 8, 40 and 80 ng/g, ranged from 97 to 103%; for endosulfan I and II, at levels of 5, 25 and 50 ng/g, ranged from 88 to 96%; for mirex, at levels of 6, 30 and 60 ng/g, ranged from 86 to 110%; and for endosulfan sulphate, at levels of 15, 75 and 150 ng/g, ranged from 93 to 104%. The method can be used for rapid determination of these pesticides in soil. © Springer-Verlag 1996.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To properly describe the interactions between the ocean and atmosphere, it is necessary to assess a variety of time and spatial scales phenomena. Here, high resolution oceanographic and meteorological data collected during an observational campaign carried out aboard a ship in the tropical Atlantic Ocean, on May 15-24, 2002, is used to describe the radiation balance at the ocean interface. Data collected by two PIRATA buoys, along the equator at 23°W and 35°W and satellite and climate data are compared with the data obtained during the observational campaign. Comparison indicates remarkable similarity for daily and hourly values of radiation fluxes components as consequence of the temporal and spatial consistence presented by the air and water temperatures measured in situ and estimated from large scale information. The discrepancy, mainly in the Sao Pedro and Sao Paulo Archipelago area, seems to be associated to the local upwelling of cold water, which is not detected in all other estimates investigated here. More in situ data are necessary to clarify whether this upwelling flow has a larger scale effect and what are the meteorological and oceanographic implications of the local upwelling area on the tropical waters at the Brazilian coast.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24°C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at -5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Brazil, the large quantities of solid waste produced are out of step with public policies, technological developments, and government budgets for the division. In small municipalities, the common lack of technological knowledge and financial conditions for suitable waste disposal has resulted in a large number of illegal dumps. Therefore, small sanitary landfill facilities are working with simplified operations focusing on cost reduction and meeting the economic and technological standards of the city without endangering the environment or public health. Currently, this activity is regulated at a federal level although there is some uncertainty regarding the risk of soil and aquifer contamination as theses facilities do not employ liners. Thus, this work evaluates a small landfill to identify changes in soil and groundwater using geotechnical parameters, monitoring wells, and geophysical tests performed by electrical profiling. It is verified that based on current conditions, no contaminants have migrated via underground water aquifers, and overall no significant changes have occurred in the soil. It is concluded that, despite its simplicity, the method investigated is a viable alternative for the final disposal of municipal solid waste from small cities, especially in developing countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)