114 resultados para Sense and reference
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper deals with the design and analysis of a Dynamic Voltage Restorer output voltage control. Such control is based on a multiloop strategy, with an inner current PID regulator and an outer P+Resonant voltage controller. The inner regulator is applied on the output inductor current. It will be also demonstrated how the load current behavior may influence in the DVR output voltage, which. justifies the need for the resonant controller. Additionally, it will be discussed the application of a modified algorithm for the identification of the DVR voltage references, which is based on a previously presented positive sequence detector. Since the studied three-phase DVR is assumed to be based on three identical H-bridge converters, all the analysis and design procedures were realized by means of single-phase equivalent circuits. The discussions and conclusions are supported by theoretical calculations, nonlinear simulations and some experimental results.
Resumo:
Symbolic power is discussed with reference to mathematics and formal languages. Two distinctions are crucial for establishing mechanical and formal perspectives: one between appearance and reality, and one between sense and reference. These distinctions include a nomination of what to consider primary and secondary. They establish the grammatical format of a mechanical and a formal world view. Such views become imposed on the domains addressed by means of mathematics and formal languages. Through such impositions symbolic power of mathematics becomes exercised. The idea that mathematics describes as it prioritises is discussed with reference to robotting and surveillance. In general, the symbolic power of mathematics and formal languages is summarised through the observations: that mathematics treats parts and properties as autonomous, that it dismembers what it addresses and destroys the organic unity around things, and that it simplifies things and reduces them to a single feature. But, whatever forms the symbolic power may take, it cannot be evaluated along a single good-bad axis.
Resumo:
This paper deals with the design and analysis of a Dynamic Voltage Restorer output voltage control. Such control is based on a multiloop strategy, with an inner current PID regulator and an outer P+Resonant voltage controller. The inner regulator is applied on the output inductor current. It will be also demonstrated how the load current behavior may influence in the DVR output voltage, which justifies the need for the resonant controller. Additionally, it will be discussed the application of a modified algorithm for the identification of the DVR voltage references, which is based on a previously presented positive sequence detector. Since the studied three-phase DVR is assumed to be based on three identical H-bridge converters, all the analysis and design procedures were realized by means of single-phase equivalent circuits. The discussions and conclusions are supported by theoretical calculations, nonlinear simulations and some experimental results. ©2008 IEEE.
Resumo:
The adoption of ERPs systems by small and middle-sized companies may not be possible due to their cost. At the same time, when adapting ERP to the company's particular needs, the user keeps depending on the system's sellers due to the lack of access and knowledge of the respective code. Free and open-source software may promote advantages to the enterprises, however, for its adoption it is necessary the development of techniques and tools in order to facilitate its deployment and code maintenance. This article emphasizes the importance of defining modeling architectures and reference models for the development and maintenance of open-source ERPs, in special the ERP5 project.
Resumo:
High Throughput Sequencing capabilities have made the process of assembling a transcriptome easier, whether or not there is a reference genome. But the quality of a transcriptome assembly must be good enough to capture the most comprehensive catalog of transcripts and their variations, and to carry out further experiments on transcriptomics. There is currently no consensus on which of the many sequencing technologies and assembly tools are the most effective. Many non-model organisms lack a reference genome to guide the transcriptome assembly. One question, therefore, is whether or not a reference-based genome assembly gives better results than de novo assembly. The blood-sucking insect Rhodnius prolixus-a vector for Chagas disease-has a reference genome. It is therefore a good model on which to compare reference-based and de novo transcriptome assemblies. In this study, we compared de novo and reference-based genome assembly strategies using three datasets (454, Illumina, 454 combined with Illumina) and various assembly software. We developed criteria to compare the resulting assemblies: the size distribution and number of transcripts, the proportion of potentially chimeric transcripts, how complete the assembly was (completeness evaluated both through CEGMA software and R. prolixus proteome fraction retrieved). Moreover, we looked for the presence of two chemosensory gene families (Odorant-Binding Proteins and Chemosensory Proteins) to validate the assembly quality. The reference-based assemblies after genome annotation were clearly better than those generated using de novo strategies alone. Reference-based strategies revealed new transcripts, including new isoforms unpredicted by automatic genome annotation. However, a combination of both de novo and reference-based strategies gave the best result, and allowed us to assemble fragmented transcripts.
Resumo:
Background: Hematology tests are useful to evaluate physiologic disturbances in fish and can provide important information for the diagnosis and prognosis of disease. Objectives: the primary purpose of this study was to define reference intervals for thrombocytes and leukocytes in healthy channel catfish (Ictalurus punctactus). In addition, the morphologic, cytochernical, and ultrastructural features of blood cells were assessed. Methods: Blood samples (0.5 mL were collected into EDTA from 40 clinically healthy catfish on a commercial fish farm in Jaboticabal, Brazil. Thrombocyte, total WBC, and differential WBC counts were determined and reference intervals were calculated as the 25-95th percentiles of data. Thrombocyte and leukocyte morphology was assessed in blood smears stained with May Griinwald-Giemsa-Wright and ultrastructurally by transmission electron microscopy. Cytochemical staining patterns were described using periodic acid-Schiff (PAS), peroxidase, nonspecific esterase, alkaline phosphatase, and toluidine blue. Results: Reference intervals were as follows: thrombocytes 58,802-99,569/mu L; total WBCs 27,460-41,523/mu L; lymphocytes 5380-11,581/mu L; monocytes 2949-7459/mu L; neutrophils 12,529-22,748/mu L, and basophils 736-2003/mu L. Neutrophils were positive for peroxidase and PAS; monocytes were positive for nonspecific esterase; and basophils were positive with toluidine blue. Conclusion: the morphologic and staining features of neutrophils and monocytes of channel catfish are similar to those of mammals, and the presence of basophils in this species was verified. These reference intervals and morphologic findings provide a foundation for future investigations on the functions and alterations of blood cells in channel catfish.
Resumo:
In this article we study the existence of shock wave solutions for systems of partial differential equations of hydrodynamics with viscosity in one space dimension in the context of Colombeau's theory of generalized functions. This study uses the equality in the strict sense and the association of generalized functions (that is the weak equality). The shock wave solutions are given in terms of generalized functions that have the classical Heaviside step function as macroscopic aspect. This means that solutions are sought in the form of sequences of regularizations to the Heaviside function that have to satisfy part of the equations in the strict sense and part of the equations in the sense of association.
Resumo:
The purpose of the work is to study the existence and nonexistence of shock wave solutions for the Burger equations. The study is developed in the context of Colombeau's theory of generalized functions (GFs). This study uses the equality in the strict sense and the weak equality of GFs. The shock wave solutions are given in terms of GFs that have the Heaviside function, in x and ( x, t) variables, as macroscopic aspect. This means that solutions are sought in the form of sequences of regularizations to the Heaviside function, in R-n and R-n x R, in the distributional limit sense.
Resumo:
Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA).Animals-Clinically normal animals (24 cattle, 22 horses, and 22 sheep).Procedures-pH; Pco(2); Po(2); total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO(3)(-), Na(+), K(+), and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation.Results-Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K(+) concentration in horses and sheep, and base excess in horses. Except for Na(+) concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported.Conclusions and Clinical Relevance-Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers. (Am J Vet Res 2010;71:515-521)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)(2) plus Mg(NO3)(2) as chemical modifier,to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 mug l(-1) Ph in 0.2% v/v HNO3) were spiked with 25 mug l(-1) Bi. For a 20 mul aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rose wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 mug l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.
Resumo:
Iridium-, Ru-, and W-coated platforms were prepared by thermal treatment of the transversely heated graphite atomizer and investigated for the simultaneous determination of As, Bi, Pb, Sb, and Se in tap water by electrothermal atomic absorption spectrometry. The maximum pyrolysis temperature for As and Bi increased in a modifier sequence W < Ru < Ir. For Pb, Sb, and Se, this sequence was W < Ru, It. Calculated characteristic masses in the presence of It, Ru, and W were 35, 33, and 35 pg for As; 63, 51, and 52 pg for Bi; 50, 32, and 34 pg for Pb; 40, 35, and 31 pg for Sb; and 39, 39, and 93 pg for Se, respectively. Ruthenium was elected as the optimum modifier.Repeatability of the measurements was typically < 6%. Recoveries of As, Bi, Pb, Sb, and Se added to tap water samples varied from 79 to 109%. Accuracy was also checked by analysis of five certified reference materials (CRMs) from the National Institute of Standards and Technology (NIST1640 - Trace Elements in Natural Water; NIST 1643d Trace Elements in Water) and High Purity Standards (Trace Metals in Drinking Water Standards, lots #812708, #591107, and #710710). A paired t-test showed that the results for the CRMs were in agreement at the 95% confidence level with the certified values. The graphite tube lifetime was about 650 firings. multi-element determination is particularly challenging due to the necessity of carefully optimizing compromise conditions.Based on the considerations listed above, the aim of this paper was to evaluate the behavior of Ir, Ru, and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se. The performance of the proposed procedure was also verified after the ETAAS analysis of tap waters and reference materials.
Resumo:
Arsenic and germanium have been evaluated as internal standards to minimize matrix effects on the direct determination of selenium in milk by graphite furnace atomic absorption spectrometry (GFAAS) using tubes with integrated platform, pre-treated with W together with I'd as chemical modifier. The efficiency of As and Ge as internal standards for 25 mu g L-1 Se plus 500 mu g (L)-1 As or Ge in diluted (1 + 9 v/v) milk plus 1.0% (v/v) HNO3 was evaluated by means of correlation graphs plotted from the normalized absorbance signals (n = 20) of internal standard (axis gamma) versus analyte (axis x). The equations that describe the linear regression were: A(As)= - 0.004 +/- 0.019 +/- 1.02 + 0.019 A(Se) (r=0.9967 +/- 0.005); A(Ge)= - 0.0 17 +/- 0.015 + 1.01 +/- 0.015 A(Se) (r = 0.9978 +/- 0.004). Samples and reference solutions were automatically spiked with 500 mu g L-1 Ge or As and 1.0% (v/v) HNO3 by the autosampler. For 20 mu L of aqueous standard solutions, analytical curves in the 5.00-40.0 mu g L-1 Se range were established using the ratio of Se absorbance to internal standard absorbance (A(Se)A(IS)) versus analyte concentration, and good linear correlations were obtained. The characteristic mass was 40 pg Se. Limits of detection were 0.55 and 0.40 mu g L-1 with As and Ge as the internal standard, respectively. Relative standard deviations (RSD) for a sample containing 25 mu g L-1 Se were 1.2% and 1.0% (n = 12) using As and Ge, respectively. The RSD without internal standardization was about 6%. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 99-105% range with IS and in the 70-80% range without IS. Using Ge as the internal standard, results of analysis of standard reference materials were in agreement with certified values at a 95% confidence level. The selenium concentration for 10 analyzed milk samples varied from 5.0 to 20 mu g L-1. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Two catalyst wastes (RNi and RAI) from polyol production were considered as hazardous, due to their respective high concentration of nickel and aluminum contents. This article presents the study, done to avoid environmental impacts, of the simultaneous solidification/stabilization of both catalyst wastes with type II Portland cement (CP) by non-conventional differential thermal analysis (NCDTA). This technique allows one to monitor the initial stages of cement hydration to evaluate the accelerating and/or retarding effects on the process due to the presence of the wastes and to identify the steps where the changes occur. Pastes with water/cement ratio equal to 0.5 were prepared, into which different amounts of each waste were added. NCDTA has the same basic principle of Differential Thermal Analysis (DTA), but differs in the fact that there is no external heating or cooling system as in the case of DTA. The thermal effects of the cement paste hydration with and without waste presence were evaluated from the energy released during the process in real time by acquiring the temperature data of the sample and reference using thermistors with 0.03 A degrees C resolution, coupled to an analog-digital interface. In the early stages of cement hydration retarding and accelerating effects occur, respectively due to RNi and RAl presence, with significant thermal effects. During the simultaneous use of the two waste catalysts for their stabilization process by solidification in cement, there is a synergic resulting effect, which allows better hydration operating conditions than when each waste is solidified separately. Thermogravimetric (TG) and derivative thermogravimetric analysis (DTG) of 4 and 24 h pastes allow a quantitative information about the main cement hydrated phases and confirm the same accelerating or retarding effects due to the presence of wastes indicated from respective NCDTA curves.