119 resultados para SPONTANEOUS ONSET
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This report describes the development of a behaviour chamber and the validation of the chamber to measure locomotor activity of a horse, Locomotor activity was detected by four Mini-beam sensors and recorded on a data logger every 5 min for 22 h. Horses were more active during daytime than in the evening, which was at least partially related to human activity in their surroundings. To validate the ability of the chambers to detect changes in activity, fentanyl citrate and xylazine HCl, agents well-characterized as a stimulant and a depressant, respectively, were administered to five horses. Fentanyl citrate (0.016 mg/kg) significantly increased locomotor activity which persisted for 30 min, Xylazine HCl (1 mg/kg) significantly reduced locomotor activity for 90 min. Amitraz produced a dose-dependent decrease in locomotor activity, lasting 75 min for the 0.05 mg/kg dose, 120 min for the 0.10 mg/kg dose, and 180 min for the 0.15 mg/kg dose, In a separate experiment, yohimbine administration immediately reversed the sedative effect of amitraz, This suggests there is a similarity in the mode of action of amitraz, xylazine and detomidine, as yohimbine acts primarily by blocking central alpha 2-adrenoceptors that are stimulated by agents like xylazine, There was also a significant decrease in locomotor activity following injection of detomidine (0.02, 0.04 and 0.08 mg/kg) for 1.5, 3.5 and 5.0 h, respectively, the locomotor chamber is a useful, sensitive and highly reproducible tool for measuring spontaneous locomotor activity in the horse, which allows investigators to determine an agent's average time of onset, duration and intensity of effect on movement.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: To describe spontaneous blink kinematics in Graves' upper eyelid retraction (UER).Methods: The magnetic search coil technique was used to record spontaneous blinks of 15 healthy subjects (aged 23-56 years, 15 eyelids) and 15 patients with Graves' UER (aged 22-62 years, 15 eyelids) during a 5-min period of video observation, and the signals were digitized at 200 Hz (12 bits). Overall, a total of 2,798 blinks were recorded for the controls and 1,860 for the patients. The distance between pupil center and upper eyelid margin in the primary position of gaze (MRD) was measured with the Image J software.Results: The blinking rate of patients was lower than that of control subjects, with a mean (+/-SEM) blinking rate (blinks/min) of 13.0 +/- 1.7 for patients and of 20.0 +/- 2.1 for the controls (t = 2.58, P = 0.016). There were no statistically significant differences in blink amplitude between controls (22.7 +/- 3.1 degrees) and Graves' patients (24.7 +/- 3.3 degrees). However, while only 22% of the blinks performed by controls were smaller than MRD, this rate was 78% for patients. In addition, in blinks larger than 25, patients showed lower down-phase velocity than controls.Conclusions: Patients with Graves' UER show reduced blinks rates and abnormal blink kinematics, which might be related to the development of exposure keratitis in this disease.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Quando da utilização de bloqueadores neuromusculares, já foi enfatizado na literatura médica humana, que é de vital imporância a monitoração do bloqueio neuromuscular e que estes agentes nunca devem ser utilizados sem a mesma. O objetivo deste estudo foi o de avaliar o uso do monitor da transmissão neuromuscular TOF-Guard em eqüinos. Para tanto, doze eqüinos foram separados aleatoriamente para receberem como bloqueadores neuromusculares o pancurônio ou o atracúrio. Todos os eqüinos foram pré-medicados com romifidina, induzidos com diazepam e quetamina e mantidos com halotano. Foi administrado o atracúrio ou o pancurônio, seguindo-se a apnéia e início da ventilação mecânica controlada. O tempo entre a administração do relaxante muscular e a obtenção de um bloqueio máximo (T1=0), o retorno do T1 para 25% e da razão do TOF para 0,7 e o tempo do retorno do T1 de 25 para 75% foram mensurados. Concluiu-se que é de grande importância a monitoração do bloqueio neuromuscular quando da utilização de um bloqueador neuromuscular não-despolarizante, uma vez que ela torna o ato anestésico e cirúrgico mais seguro, com a utilização de doses adequadas que inviabilizam a superficialização do bloqueio durante o procedimento cirúrgico. O monitor TOF-Guard mostrou ser uma boa opção para a monitoração do bloqueio neuromuscular em eqüinos.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Somatotrophic and thyroid hormones were determined around the onset of reproduction in broiler breeders reared in two different housing systems [dark, close-sided house (CH) and conventional, open-sided house (OH)]. In both groups age-related changes were obvious for thyroxine (T-4), growth hormone (GH) and insulin-like growth factor (IGF-1); levels of T-4 decreased, especially between 24 and 28 weeks in both groups; concomitantly GH sharply increased over the same period. A transient peak in triiodothyronine (T-3) occurred between 25 and 27 weeks. The effect of housing was only present after the onset of lay. Between weeks 27-28 and the end of the period studied, the CH group showed higher levels of GH and T-3 but lower T-4 levels as compared to the OH group. A significant increase in GH after onset of lay, without any significant rise in T-3 or in IGF-I, could point to a relative insensitivity to high plasma GH levels. Changes at GH receptor level, together with an increased pituitary GH secretion and/or decreased GH turnover may be expected. This may indicate that hypothalamo-pituitary changes at the onset of lay not only imply changes of gonadotrophic cell function, but also other hormonal axes. The relatively decrease in T-4 without changes in T-3, may point to a decrease in the activity of the thyrotropic axis.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective To compare the cardiorespiratory effects and incidence of gastroesophageal reflux with the use of a laryngeal mask airway (LMA) or endotracheal tube (ET) in anesthetized cats during spontaneous (SV) or controlled ventilation (CV).Study design Prospective randomized experimental trial.Animals Thirty-two adult crossbred cats, weighing 2.7 +/- 0.4 kg.Methods the cats were sedated with intramuscular (IM) methotrimeprazine (0.5 mg kg(-1)) and buprenorphine (0.005 mg kg(-1)), followed 30 minutes later by induction of anesthesia with intravenous (IV) thiopental (12.5-20 mg kg(-1)). An ET was used in 16 cats and an LMA in the remaining 16 animals. Anesthesia was maintained with 0.5 minimum alveolar concentration (0.6%) of halothane in oxygen using a Mapleson D breathing system. Cats in both groups were further divided into two equal groups (n = 8), undergoing either SV or CV. Neuromuscular blockade with pancuronium (0.06 mg kg(-1)) was used to facilitate CV. Heart and respiratory rates, direct arterial blood pressure, capnometry (PE'CO2) and arterial blood gases were measured. Gastric reflux and possible aspiration was investigated by intragastric administration of 5 mL of radiographic contrast immediately after induction of anesthesia. Cervical and thoracic radiographs were taken at the end of anesthesia. Data were analyzed using ANOVA followed by Student-Newman-Keuls, Kruskal-Wallis or Friedman test where appropriate.Results Values for PaCO2 and PE'CO2 were higher in spontaneously breathing cats with the LMA when compared with other groups. Values of PaO2 and hemoglobin oxygen saturation did not differ between groups. Gastroesophageal reflux occurred in four of eight and two of eight cats undergoing CV with ET or LMA, respectively. There was no tracheal or pulmonary aspiration in any cases.Conclusions and clinical relevance the use of an LMA may be used as an alternative to endotracheal intubation in anesthetized cats. Although aspiration was not observed, gastric reflux may occur in mechanically ventilated animals.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
CONTEXTO: Mães relatam início precoce de constipação em crianças atendidas em clínicas de gastroenterologia. OBJETIVOS: Estudar o hábito intestinal em crianças de baixa idade na comunidade, para avaliar se início precoce da constipação é confirmado neste contexto e se há concordância entre o hábito intestinal relatado e o registrado prospectivamente. MÉTODOS: Obtiveram-se dados sobre evacuações de 57 crianças com idade 6.0-40.7 meses, mediante relato materno (questionário sobre características fecais predominantes) e, a seguir, foram registradas 1.934 evacuações em casa e na creche. O hábito intestinal foi classificado como adequado, constipação, diarréia funcional, outro hábito intestinal, conforme frequência evacuatória e proporção das características fecais (macias, duras e/ou que escorrem). Usaram-se dois critérios para classificar o hábito intestinal registrado, devido indefinição no ponto de corte para fezes duras na identificação de constipação em crianças: critério predominante e critério adulto, respectivamente com >50% e >25% de evacuações com consistência alterada. Usou-se estatística não-paramétrica e, para concordância entre hábito intestinal relatado e registrado, o índice Kappa. RESULTADOS: Constipação ocorreu em 17.5%, 10.5%, 19.3% das crianças, respectivamente pelo relato e pelo registro segundo critérios predominante e adulto. Constipação foi o hábito intestinal mais frequentemente relatado, versus 12.3% outro hábito intestinal. Só uma criança se classificou como tendo diarréia funcional (pelo critério adulto). Concordância entre o hábito intestinal relatado e o registrado foi razoável (fair) para constipação, pelos critérios predominante e adulto (K=0.28 e 0.24, respectivamente), mas apenas leve (slight) para os demais hábito intestinal (K <0.16). Entretanto, dados individuais indicaram melhor relação entre relato de constipação com o critério adulto do que com o critério predominante. CONCLUSÕES: Confirmou-se que constipação é frequente e de início precoce. Concordância razoável entre o hábito intestinal relatado e o registrado segundo os dois critérios indica que o relato materno é razoavelmente confiável para detectar constipação.