11 resultados para Rushworth Gloss.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the gloss behaviour of experimental resin composites loaded with different filler percentages, immediately after polishing and after toothbrushing simulation. Methods: Sixteen disc-shaped specimens were fabricated for each different-charged composite (40%, 50%, 60%, 70% and 75%) and polished with SiC abrasive papers. Gloss measurements were made prior to simulated toothbrushing. The specimens were subjected to the simulation for 5, 15, 30 and 60 min using an electrical toothbrush with a standardized pressure while being immersed in a toothpaste/artificial saliva slurry. Results: Baseline composite gloss values ranged from 69.7 (40%) to 81.3 (75%) GU (gloss units) and from 18.1 (40%) to 32.3 (75%) GU after 1 h of brushing. Highest gloss values were obtained by 75%-charged resin, while the lowest values were obtained by the 40%-charged one. Conclusions: All tested materials showed a gloss decrease. However, the higher filler load a composite resin has, the higher gloss it can achieve. Clinical significance: Gloss of resin composite materials is an important factor in determining aesthetic success of anterior restorations, and this property may vary according to the filler charge of the restorative material. Higher filler load of a composite resin results in higher gloss values. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of finishing and polishing techniques on surface roughness of resin-based composites (RBCs). Materials and Methods: Forty specimens of each material were cured under Mylar strips and immersed in artificial saliva for 1 wk. Samples were tested with a profilometer to obtain baseline average surface roughness (Ra). Specimens of both RBCs were then finished and polished according to four techniques: (1) Sof-Lex disks; (2) Sof-Lex disks followed by Prisma Gloss; (3) Enhance points; (4) Enhance points followed by Prisma Gloss application. New readings of the roughness pattern were carried out and the difference of post-polishing and baseline values were analyzed. Results: ANOVA test (alpha= 0.05) did not show differences between materials (P= 0.9393) nor interaction effects (P= 0.3094), but significant difference among the finishing/polishing techniques were detected (P= 0.0157). Tukey's test showed that the smoothest surface was obtained when the specimens were treated by Sof-Lex followed by Prosma Gloss polishing paste; and the worst results were obtained after using Enhance points alone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: the purpose of this study was to evaluate the effectiveness of various surface treatments for resin-modified glass-ionomer restorative materials by determining dye uptake spectrophotometrically. Method and materials: Two hundred twenty-four specimens, 4.1 mm in diameter and 2.0 mm thick, were made of 3 materials: Vitremer, Fuji II LC, and Photac-Fil Aplicap. Specimens were divided into 15 groups. The positive and negative control specimens remained unprotected, while the experimental specimens were protected with Heliobond light-activated bonding resin, Colorama nail varnish, or surface coatings indicated by the manufacturers of the glass-ionomer materials. Finishing Gloss for Vitremer, Fuji Varnish for Fuji II LC, and Ketac Glaze for Photac-Fil. The disks were immersed in 0.05% methylene blue for 24 hours except for the negative control group, which was immersed in deionized water. After 24 hours, the disks were removed, washed, and individually placed in 1 mL of 65% nitric acid for 24 hours. The solutions were centrifuged and the spectrophotometric absorbance was determined at 606 nm. The dye uptake was expressed in micrograms of dye per milliliter, and the results were analyzed with the Kruskal-Wallis test. Results: There were no differences in dye uptake among the 3 resin-modified glass-ionomer restorative materials, however, all of them required surface protection. Conclusion: the best surface protection for the 3 evaluated materials was obtained with Heliobond light-activated bonding resin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work has been performed at Tapetes Sao Carlos-Brazil with the cooperation of the DaimlerChrysler Research Center Team in Ulm - Germany. The objective of the present paper is to report the results obtained with natural fiber reinforced unsaturated polyester (UP) composites, concerning surface quality measurements. The fibers that have been chosen for this work were sisal and curaua. The samples were produced by compression molding technique and afterwards submitted to three different tests, namely: a) thermal aging; b) water absorption and c) artificial weathering. The surface parameters measured before and after the tests were gloss, haze, short and long-waviness. The results have shown that after the tests there is a high loss of gloss, a high increase in haze, and a high increase in short and long-waviness as well. Curaua reinforced composites had a slightly better behavior when compared with sisal reinforced composites. The effect of the presence of filler and the addition of thermoplastic polyester (TP) on the material behavior has not been evidently detected. This result shows that the conventional technology/methods applied to UP-Fiberglass systems cannot be transferred to natural fibers without any modification. The fiber-matrix interaction and its response to the presence of additives must be fully understood before a successful processing route can be developed for painted natural fibers reinforced UP. Copyright © 2001 Society of Automotive Engineers, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work was based to study the influence of the storage temperature (cold and room temperature) in the quality of inflorescences strelitzia. The scapes were selected, labeled and there were zero problems concerning mechanical damage, disease and/or plagues. Subsequently this period, the scapes were moved randomly to recipients with water, in which two postharvest trials were conducted. In experiment 1, the flower scapes were placed in buckets with water from public supply and sanitation department and taken to a cold room at temperature of 7.5 degrees C and RH of 90%, for a twelve day period. For the experiment 2, were kept under the same conditions but at room temperature for a period of six days. In both experiments, the visual analysis: color, gloss, stains (by assigning notes), opening and drop florets (count) were evaluated at intervals of four days in cold and every 48 hours at ambient temperature conditions. In both experiments, the visual analysis: color, gloss, stains (by assigning notes), opening and drop florets (count) were evaluated at intervals of four days in cold and every 48 hours at ambient temperature conditions. The sepal is the organ that showed greater loss in coloration. The variable gloss showed the same pattern for the two experiments. Incidences of stains on the inflorescences occurred in patches at room temperature. The scapes increased number of florets open in cold. This tendency did not occur at room temperature. No were observed differences in the fall of florets. Conclude that the storage temperature does not contribute to postharvest quality of strelitzia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To ensure the ongoing quality of anthurium inflorescence it is necessary to use postharvest treatments aimed at extending the vase life and delaying senescence. Thus, the objective of this study was to assess the effect of postharvest spray application of 6-benzylaminopurine (BAP) in anthurium quality and sugar levels. Two experiments were done, one where inflorescences were sprayed 0, 100 and 200 mg L-1 of BAP and kept under 23±1°C and relative humidity of 65±5% for evaluations, and in the second experiment BAP concentrations were reduced to 0, 50 and 100 mg L-1 and inflorescences were cold stored for 2 days at 13±1°C and then transferred to the same evaluation conditions from the first experiment. Quality assessments were performed according to Paull (1982) for spathe loss of gloss and blueing and spadix necrosis along with stem weighting for fresh weight (FW) variation every two days. In the first experiment FW loss was significantly lower from the 14th until 26th day after harvest. Anthurium sprayed with 100 and 200 mg L-1 showed significantly less fresh weight loss when compared to control stems and in the second experiment 50 and 100 mg L-1 did not reduce fresh weight loss. Means of scores from quality analysis, blueing and loss of gloss of spathes and spadix necrosis, were significantly lower in BAP sprayed anthurium (100 and 200 mg L-1) than in control flowers and by lowering BAP spray concentration and cold storing stems for two days this positive effect was only observed for spadix necrosis and not observed for spathe parameters.