118 resultados para Rotational angle

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Small-angle X-ray scattering (SAXS) and electron paramagnetic resonance (EPR) have been carried out to investigate the structure of the self-aggregates of two phenothiazine drugs, chlorpromazine (CPZ) and trifluoperazine (TFP), in aqueous solution. In the SAXS studies, drug solutions of 20 and 60 mM, at pH 4.0 and 7.0, were investigated and the best data fittings were achieved assuming several different particle form factors with a homogeneous electron density distribution in respect to the water environment. Because of the limitation of scattering intensity in the q range above 0.15 angstrom(-1), precise determination of the aggregate shape was not possible and all of the tested models for ellipsoids, cylinders, or parallelepipeds fitted the experimental data equally well. The SAXS data allows inferring, however, that CPZ molecules might self-assemble in a basis set of an orthorhombic cell, remaining as nanocrystallites in solution. Such nanocrystals are composed of a small number of unit cells (up to 10, in c-direction), with CPZ aggregation numbers of 60-80. EPR spectra of 5- and 16-doxyl stearic acids bound to the aggregates were analyzed through simulation, and the dynamic and magnetic parameters were obtained. The phenothiazine concentration in EPR experiments was in the range of 5-60 mM. Critical aggregation concentration of TFP is lower than that for CPZ, consistent with a higher hydrophobicity of TFP. At acidic pH 4.0 a significant residual motion of the nitroxide relative to the aggregate is observed, and the EPR spectra and corresponding parameters are similar to those reported for aqueous surfactant micelles. However, at pH 6.5 a significant motional restriction is observed, and the nitroxide rotational correlation times correlate very well with those estimated for the whole aggregated particle from SAXS data. This implies that the aggregate is densely packed at this pH and that the nitroxide is tightly bound to it producing a strongly immobilized EPR spectrum. Besides that, at pH 6.5 the differences in motional restriction observed between 5- and 16-DSA are small, which is different from that observed for aqueous surfactant micelles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: This study assessed the anterior-posterior positioning of the upper and lower first molars, and the degree of rotation of the upper first molars in individuals with Class II, division 1, malocclusion. METHODS: Asymmetry I, an accurate device, was used to assess sixty sets of dental casts from 27 females and 33 males, aged between 12 and 21 years old, with bilateral Class II, division 1. The sagittal position of the molars was determined by positioning the casts onto the device, considering the midpalatal suture as a symmetry reference, and then measuring the distance between the mesial marginal ridge of the most distal molar and the mesial marginal ridge of its counterpart. With regard to the degree of rotation of the upper molar, the distance between landmarks on the mesial marginal ridge was measured. Chi-square test with a 5% significance level was used to verify the variation in molars position. Student's t test at 5% significance was used for statistical analysis. RESULTS: A great number of lower molars mesially positioned was registered, and the comparison between the right and left sides also demonstrated a higher number of mesially positioned molars on the right side of both arches. The average rotation of the molars was found to be 0.76 mm and 0.93 mm for the right and left sides, respectively. CONCLUSION: No statistically significant difference was detected between the mean values of molars mesialization regardless of the side and arch. Molars rotation, measured in millimeters, represented ¼ of Class II.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of nitrogen on the root system of the species Panicum maximum Jacq. cv. IPR-86 Mil (e) over cap nio, under grazing, was evaluated. The N rates were 0; 150; 300 and 450 kg/ha. year. The root density was evaluated during pregrazing at five years of successive N application, in three depths (0-10; 10-20 and 20-40 cm) and the root growth at 7, 14, 21, and 35 days after grazing. The grazing method adopted was rotational stocking. Root length and root mass densities in pre-and post-grazing presented maximum values at rates 204, 206, 192, and 197 kg/ha of N, respectively. The root growth (in root length density) increased, on average, until 29 days after grazing at rates 0, 150, and 300 kg/ha; at 450 kg/ha N rate, the increase was linear. Independently of N rates, around 60 and 25% of IPR-86 Mil (e) over cap nio cultivar root system was concentrated in 0-10 and 10-20 cm depth, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a different experimental setup compared with the traditional ones, in order to determine the acceleration of gravity, which is carried out by using a fluid at a constant rotation. A computerized rotational system-by using a data acquisition system with specific software, a power amplifier and a rotary motion sensor-is employed in order to evaluate the angular velocity and g. An equation to determine g is inferred from fluid mechanics. For this purpose, the fluid's parabolic shape inside a cylindrical receptacle is considered using a rotational movement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surfaces of silicon wafers implanted with N and C, respectively, and aluminum 5052 implanted with N alone by plasma immersion ion implantation WHO were probed by a nanoindentor and analyzed by the contact-angle method to provide information on surface nanohardness and wettability. Silicon nitride and silicon carbide are important ceramic materials for microelectronics, especially for high-temperature applications. These compounds can be synthesized by high-dose ion implantation. The nanohardness of a silicon sample implanted with 12-keV nitrogen PIII (with 3 X 10(17) cm(-2) dose) increased by 10% compared to the unimplanted sample, in layers deeper than the regions where the formation of the Si,N, compound occurred. A factor of 2.5 increase in hardness was obtained for C-implanted Si wafer at 35 keV (with 6 X 10(17) cm(-2) dose), again deeper than the SiC-rich layer, Both compounds are in the amorphous state and their hardness is much lower than that of the crystalline compounds, which require an annealing process after ion implantation. In the same targets, the contact angle increased by 65% and 35% for N- and C-implanted samples, respectively. Compared to the Si target, the nitrogen PIII-irradiated Al 5052 (wish 15 keV) showed negligible change in its hydrophobic character after ion implantation. Its near-surface nanohardness measurement showed a slight increase for doses of 1 X 10(17) cm(-2). We have been searching for an AlN layer of the order of 1000 A thick, using such a low-energy PIII process, but oxide formation during processing has precluded its synthesis. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rotational motion of an artificial satellite is studied by considering torques produced by gravity gradient and direct solar radiation pressure. A satellite of circular cylinder shape is considered here, and Andoyers variables are used to describe the rotational motion. Expressions for direct solar radiation torque are derived. When the earth's shadow is not considered, an analytical solution is obtained using Lagrange's method of variation of parameters. A semi-analytical procedure is proposed to predict the satellite's attitude under the influence of the earth's shadow. The analytical solution shows that angular variables are linear and periodic functions of time while their conjugates suffer only periodic variations. When compared, numerical and analytical solutions have a good agreement during the time range considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three sets of non-singular canonical variables for the rotational motion are analyzed. These sets are useful when the angle between z-axis of a coordinate system fixed in artificial satellite ( here defined by the directions of principal moments of inertia of the satellite) and the rotational angular momentum vector is zero or when the angle between Z-inertial axis and rotational angular momentum vector is zero. The goal of this paper is to compare all these sets and to determine the benefits of their uses. With this objective, the dynamical equations of each set were derived, when mean hamiltonian associate with the gravity gradient torque is included. For the torque-free rotational motion, analytical solutions are computed for symmetrical satellite for each set of variables. When the gravity gradient torque is included, an analytical solution is shown for one of the sets and a numerical solution is obtained for one of the other sets. By this analysis we can conclude that: the dynamical equation for the first set is simple but it has neither clear geometrical nor physical meaning; the other sets have geometrical and physical meaning but their dynamical equations are more complex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report presents the use of a dental implant with an anti-rotational attachment for the retention of a thumb prosthesis. A retention system was manufactured with an attachment (UCLA) screwed into the implant with a two-bar system that was cast in metallic silver palladium. A substructure made from heat-cured acrylic resin was joined to the retention system by clips to join the thumb to the finger (bar clip) in the cast with implant rejoinder. The silicone material, Silastic-MDX 44210, was used to achieve function and aesthetics. Following osseointegration, no skin problems were observed. Whilst the implant-retained digital prosthesis presented some motor limitations, it allowed the patient to return to entertainment and achieve social conviviality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: as oclusopatias estão entre os principais problemas de saúde bucal em todo o mundo, juntamente com a cárie dentária e a doença periodontal, e vários índices têm sido utilizados para registrá-las. OBJETIVOS: verificar a prevalência de oclusopatias utilizando a Classificação de Angle e o Índice de Estética Dentária (DAI), sua severidade e a necessidade de tratamento ortodôntico registradas pelo DAI, e comparar os resultados de ambos os índices, visando correlacionar o padrão dos dados coletados e a viabilidade de utilizá-los de forma conjunta. MÉTODOS: a amostra consistiu de 734 escolares com idade de 12 anos, de ambos os sexos, da rede pública do município de Lins/SP. Foram realizados exames nos pátios das escolas com utilização de sondas IPC a olho nu. RESULTADOS: pela Classificação de Angle, encontrou-se 33,24% das crianças com oclusão normal e 66,76% com má oclusão. Pelo DAI, observou-se que 65,26% das crianças apresentavam-se sem anormalidades ou com más oclusões leves. A má oclusão definida esteve presente em 12,81%, a má oclusão severa foi observada em 10,90% e a muito severa ou incapacitante em 11,03%. A maioria das crianças (70,57%) apresentou relação molar normal, e o overjet maxilar anterior foi a alteração mais frequentemente observada. No cruzamento dos índices houve semelhanças e divergências. CONCLUSÃO: o DAI não foi sensível a alguns problemas de oclusão detectados pela Classificação de Angle, e a recíproca foi verdadeira, demonstrando que ambos os índices possuem pontos distintos na detecção das oclusopatias, podendo ser utilizados de forma reciprocamente complementar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: o presente trabalho tem o propósito de apresentar uma revisão da literatura acerca do tratamento da má oclusão de Classe II, divisão 1 de Angle, tendo a protrusão maxilar como o principal componente dessa má oclusão, durante a fase de crescimento e desenvolvimento craniofacial. Serão apresentadas as características de cada um desses aparelhos, os seus componentes, a forma adequada de utilização, os seus mecanismos de ação e, principalmente, os seus efeitos em todo o complexo dentofacial. CONCLUSÃO: nos casos em que se verifica apenas a protrusão maxilar, sem envolvimento mandibular, e se faz necessário o controle vertical, pode ser indicado o AEB, conjugado ao aparelho removível derivado do aparelho preconizado por Thurow. Já nas situações de combinação da protrusão maxilar com a retrusão mandibular, uma opção de tratamento é o ativador combinado à ancoragem extrabucal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo foi realizado com o propósito de avaliar respostas cefalométricas ao tratamento com aparelho extrabucal de Kloehn associado ao aparelho fixo edgewise convencional. Telerradiografias iniciais (T1) e finais (T2) de dois grupos de 30 pacientes tratados com estes aparelhos foram selecionadas e definidas pelo índice cefalométrico de Jarabak para determinação do padrão esquelético craniofacial. Os grupos foram denominados favorável (hipodivergente) e desfavorável (hiperdivergente). A idade média, no início do tratamento, foi de 11,03 anos e final de 14,72 com o tempo médio de tratamento de 3,6 anos para o grupo favorável. No grupo desfavorável a idade inicial foi de 11,51 anos e final de 15,17 anos com tempo médio de tratamento de 3,4 anos. Foi utilizado um sistema de análise de resposta de tratamento em coordenadas X e Y representativos dos movimentos dentários e das bases ósseas decompondo-os em seus vetores horizontais e verticais. Os resultados e respostas do tratamento foram analisados e comparados entre os grupos favorável e desfavorável utilizando o teste t-Student. Os resultados mostraram não haver diferenças estatisticamente significantes na resposta cefalométrica no tratamento com o aparelho extrabucal de Kloehn associados ao aparelho fixo edgewise quanto aos padrões faciais favorável e desfavorável. O tratamento promoveu uma restrição do deslocamento anterior maxilar e um menor deslocamento anterior mandibular. Quanto à movimentação dentária maxilar, houve uma restrição do movimento mesial e extrusivo dos molares superiores no grupo favorável, enquanto que o movimento dos dentes inferiores foi mínimo no sentido anterior e vertical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fractures of the mandibular angle deserve particular attention because they represent the highest percentage of mandibular fractures and have the highest postsurgical complication rate, making them the most challenging and unpredictable mandibular fractures to treat. Despite the evolution in the treatment of maxillofacial trauma and fixation methods, no single treatment modality has been revealed to be ideal for mandibular angle fractures. Several methods of internal fixation have been studied with great variation in complications rates, especially postoperative infections. Recently, new studies have shown reduction of postsurgical complications rates using three-dimensional plates to treat mandibular angle fractures. Nevertheless, only few surgeons have used this type of plate for the treatment of mandibular angle fractures. The aim of this clinical report was to describe a case of a patient with a mandibular angle fracture treated by an intraoral approach and a three-dimensional rectangular grid miniplate with 4 holes, which was stabilized with monocortical screws. The authors show a follow-up of 8 months, without infection and with occlusal stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)