7 resultados para Revision and termination of contracts

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper proposes a framework for the analysis and representation of external systems for online optimisation studies. The basis for this framework is the equivalent OPF (EOPF), an optimisation model obtained by partitioning of the OPF model. The EOPF is mathematically redefined in the paper to accommodate the concept of a buffer zone. The resulting model is more useful for online optimisation, since external information obtained through intercontrol-centre exchange contracts can be used to improve internal control calculation. Numerical results obtained with original studies involving the boundary-matching procedure have provided a conceptual basis for the definition of a buffer zone for optimisation studies with the EOPF. In the proposed framework, the accuracy of the external representation in optimisation studies is evaluated by comparing the controls obtained by an EOPF procedure with those obtained by the reference-optimisation procedure defined in this paper. The framework is then used to evaluate the accuracy of equivalent optimisation studies involving the IEEE 118-bus test system and the Brazilian South Southeast 810-bus system. The results show that the incorporation of a buffer zone improves the external system representation for all optimisation studies performed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O pseudomixoma peritoneal é uma condição patológica que acomete o peritoneo, caracterizada pela produção de grandes quantidades de líquido mucinoso, que progressivamente preenche a cavidade peritoneal, tendo em geral como origem tumores mucinosos apendiculares ou de ovário. Relatamos a ocorrência de um pseudomixoma peritoneal associado a adenocarcinoma mucinoso do apêndice sincrônico e adenocarcinoma do reto em paciente de 44 anos, cujo diagnóstico inicial foi de adenocarcinoma do reto. A neoplasia do apêndice e o pseudomixoma peritonial foram achados incidentais, intra-operatórios. Enfocamos as principais características anatomo-patológicas das lesões, o diagnóstico e tratamento, através de ampla revisão da literatura.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A microactuator made from poly(vinylidene fluoride) (PVDF), a piezoelectric polymer, was fabricated to control the gas flow rate through a glass micronozzle. The actuator was formed by gluing together two PVDF sheets with opposite polarization directions. The sheets were covered with thin conducting films on one side, that were then used as electrodes to apply an electric field to move the valve. The actuator has a rectangular shape, 3 mm x 6 mm. The device was incorporated with a micronozzle fabricated by a powder blasting technique. Upon applying a DC voltage across the actuator electrodes, one sheet expands while the other contracts, generating an opening motion. A voltage of +300 V DC was used to open the device by moving the actuator 30 mu m, and a voltage of -200 V DC was used to close the device by moving the actuator 20 mu m lower than the relaxed position. Flow measurements were performed in a low-pressure vacuum system, maintaining the microvalve inlet pressure constant at 266 Pa. Tests carried out with the actuator in the open position and with a pressure ratio (inlet pressure divided by outlet pressure) of 0.5, indicated a flow rate of 0.36 sccm. In the closed position, and with a pressure ratio of 0.2, a flow rate of 0.32 sccm was measured.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Networked control systems (NCSs) are distributed control systems in which the sensors, actuators, and controllers are physically separated and connected through an industrial network. The main challenge related to the development of NCSs is the degenerative effects caused by the inclusion of this communication network in the closed loop control. In order to mitigate these effects, co-simulation tools for NCS have been developed to study the network influence in the NCS. This paper presents a revision about co-simulation tools for NCS and the application of two of these tools for the design and evaluation of NCSs. The TrueTime and Jitterbug tools were used together to evaluate the main configuration parameter that affects the performance of CAN-based NCS and to verify the NCS quality of control under various timing conditions including different transmission period of messages and network delays. Therefore, the simulation results led to the conclusion that despite the transmission period of messages is the most significant factor among the analyzed in the design of NCS, its influence is related to the kind of system with greater effects in NCSs with fast dynamics.