37 resultados para Reliability and safeties
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aims of this study were to evaluate the reliability and to validate a Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (OHIP-EDENT), an inventory for measuring oral health-related quality of life of edentulous subjects. The sample comprised 65 complete denture wearers (23 men, mean age of 69.1 +/- 10.3 years). The translated OHIP-EDENT was applied on two occasions with a washout period of 3 months. Reliability was assessed by an internal consistency analysis and a test-retest approach. A preliminary validation process was conducted by a qualitative approach/interview. Results of internal consistency showed a Cronbach's alpha of 0.86 or 0.90 for the first or second appointment respectively. Through the test-retest analysis, an intra-class correlation coefficient of 0.57 was found, and individual answers reflected a broad range of agreement. Interviewed volunteers (n = 6) comprehended most questions well. In conclusion, the Brazilian version of OHIP-EDENT is adequate for assessing the oral health-related quality of life for edentulous subjects.
Resumo:
Internet data collection is becoming increasingly popular in all research fields dealing with human perceptions, behaviors and opinions. Advantages of internet data collection, when compared to the traditional paper-and-pencil format, include reduced costs, automatic database creation, and the absence of researcher-related bias effects, such as availability and complete anonymity. However, the validity and reliability of internet gathered data must be established, in comparison to the usual paper-and-pencil accepted formats, before an inferential analysis can be done. In this study, we compared questionnaire data gathered from the internet with that from the traditional paper-and-pencil in a sample of college students. The questionnaires used were the Maslach Burnout Inventory - Student Survey (MBI-SS), the Oldenburg Burnout Inventory (OBI-SS) and the Copenhagen Burnout Inventory (CBI-SS). Data was gathered through a within-subject cross randomized and counterbalanced design, on both internet and paper-and-pencil formats. The results showed no interference in the application order, and a good reliability for both formats. However, concordance between answers was generally higher in the paper-and-pencil format than on the internet. The factorial structure was invariant in the three burnout inventories. Data gathered in this study supports the Internet as a convenient, user-friendly, comfortable and secure data gathering method which does not affect the accepted factorial structures existent in the paper format of the three burnout inventories used. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Background: Neuropsychiatric symptoms (NPS) affect almost all patients with dementia and are a major focus of study and treatment. Accurate assessment of NPS through valid, sensitive and reliable measures is crucial. Although current NPS measures have many strengths, they also have some limitations (e.g. acquisition of data is limited to informants or caregivers as respondents, limited depth of items specific to moderate dementia). Therefore, we developed a revised version of the NPI, known as the NPI-C. The NPI-C includes expanded domains and items, and a clinician-rating methodology. This study evaluated the reliability and convergent validity of the NPI-C at ten international sites (seven languages). Methods: Face validity for 78 new items was obtained through a Delphi panel. A total of 128 dyads (caregivers/patients) from three severity categories of dementia (mild = 58, moderate = 49, severe = 21) were interviewed separately by two trained raters using two rating methods: the original NPI interview and a clinician-rated method. Rater 1 also administered four additional, established measures: the Apathy Evaluation Scale, the Brief Psychiatric Rating Scale, the Cohen-Mansfield Agitation Index, and the Cornell Scale for Depression in Dementia. Intraclass correlations were used to determine inter-rater reliability. Pearson correlations between the four relevant NPI-C domains and their corresponding outside measures were used for convergent validity. Results: Inter-rater reliability was strong for most items. Convergent validity was moderate (apathy and agitation) to strong (hallucinations and delusions; agitation and aberrant vocalization; and depression) for clinician ratings in NPI-C domains. Conclusion: Overall, the NPI-C shows promise as a versatile tool which can accurately measure NPS and which uses a uniform scale system to facilitate data comparisons across studies. Copyright © 2010 International Psychogeriatric Association.
Resumo:
Objectives: This study evaluated the reliability and failure modes of implants with a microthreaded or smooth design at the crestal region, restored with screwed or cemented crowns. The postulated null hypothesis was that the presence of microthreads in the implant cervical region would not result in different reliability and strength to failure than smooth design, regardless of fixation method, when subjected to step-stress accelerated life-testing (SSALT) in water. Materials and methods: Eighty four dental implants (3.3 × 10 mm) were divided into four groups (n = 21) according to implant macrogeometric design at the crestal region and crown fixation method: Microthreads Screwed (MS); Smooth Screwed (SS); Microthreads Cemented (MC), and Smooth Cemented (SC). The abutments were torqued to the implants and standardized maxillary central incisor metallic crowns were cemented (MC, SC) or screwed (MS, SS) and subjected to SSALT in water. The probability of failure versus cycles (90% two-sided confidence intervals) was calculated and plotted using a power law relationship for damage accumulation. Reliability for a mission of 50,000 cycles at 150 N (90% 2-sided confidence intervals) was calculated. Differences between final failure loads during fatigue for each group were assessed by Kruskal-Wallis along with Benferroni's post hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value (confidence interval range) derived from use level probability Weibull calculation of 1.30 (0.76-2.22), 1.17 (0.70-1.96), 1.12 (0.71-1.76), and 0.52 (0.30-0.89) for groups MC, SC, MS, and SS respectively, indicated that fatigue was an accelerating factor for all groups, except for SS. The calculated reliability was higher for SC (99%) compared to MC (87%). No difference was observed between screwed restorations (MS - 29%, SS - 43%). Failure involved abutment screw fracture for all groups. The cemented groups (MC, SC) presented more abutment and implant fractures. Significantly higher load to fracture values were observed for SC and MC relative to MS and SS (P < 0.001). Conclusion: Since reliability and strength to failure was higher for SC than for MC, our postulated null hypothesis was rejected. © 2012 John Wiley & Sons A/S.
Resumo:
Objective: Biological and mechanical implant-abutment connection complications and failures are still present in clinical practice, frequently compromising oral function. The purpose of this study was to evaluate the reliability and failure modes of anterior single-unit restorations in internal conical interface (ICI) implants using step-stress accelerated life testing (SSALT). Materials and methods: Forty-two ICI implants were distributed in two groups (n = 21 each): group AT-OsseoSpeed™ TX (Astra Tech, Waltham, MA, USA); group SV-Duocon System Line, Morse Taper (Signo Vinces Ltda., Campo Largo, PR, Brazil). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to SSALT in water. Use-level probability Weibull curves and reliability for a mission of 50,000 cycles at 200 N were calculated. Differences between groups were assessed by Kruskal-Wallis along with Bonferroni's post-hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value derived from use level probability Weibull calculation was 1.62 (1.01-2.58) for group AT and 2.56 (1.76-3.74) for group SV, indicating that fatigue was an accelerating factor for failure of both groups. The reliability for group AT was 0.95 and for group SV was 0.88. Kruskal-Wallis along with Bonferroni's post-hoc tests showed no significant difference between the groups tested (P > 0.27). In all specimens of both groups, the chief failure mode was abutment fracture at the conical joint region and screw fracture at neck's region. Conclusions: Reliability was not different between investigated ICI connections supporting maxillary incisor crowns. Failure modes were similar. © 2012 John Wiley & Sons A/S.
Resumo:
ABSTRACT Background: Patients with dementia may be unable to describe their symptoms, and caregivers frequently suffer emotional burden that can interfere with judgment of the patient's behavior. The Neuropsychiatric Inventory-Clinician rating scale (NPI-C) was therefore developed as a comprehensive and versatile instrument to assess and accurately measure neuropsychiatric symptoms (NPS) in dementia, thereby using information from caregiver and patient interviews, and any other relevant available data. The present study is a follow-up to the original, cross-national NPI-C validation, evaluating the reliability and concurrent validity of the NPI-C in quantifying psychopathological symptoms in dementia in a large Brazilian cohort. Methods: Two blinded raters evaluated 312 participants (156 patient-knowledgeable informant dyads) using the NPI-C for a total of 624 observations in five Brazilian centers. Inter-rater reliability was determined through intraclass correlation coefficients for the NPI-C domains and the traditional NPI. Convergent validity included correlations of specific domains of the NPI-C with the Brief Psychiatric Rating Scale (BPRS), the Cohen-Mansfield Agitation Index (CMAI), the Cornell Scale for Depression in Dementia (CSDD), and the Apathy Inventory (AI). Results: Inter-rater reliability was strong for all NPI-C domains. There were high correlations between NPI-C/delusions and BPRS, NPI-C/apathy-indifference with the AI, NPI-C/depression-dysphoria with the CSDD, NPI-C/agitation with the CMAI, and NPI-C/aggression with the CMAI. There was moderate correlation between the NPI-C/aberrant vocalizations and CMAI and the NPI-C/hallucinations with the BPRS. Conclusion: The NPI-C is a comprehensive tool that provides accurate measurement of NPS in dementia with high concurrent validity and inter-rater reliability in the Brazilian setting. In addition to universal assessment, the NPI-C can be completed by individual domains. © International Psychogeriatric Association 2013.
Influence of abutment-to-fixture design on reliability and failure mode of all-ceramic crown systems
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.
Resumo:
In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.
Resumo:
Optimised placement of control and protective devices in distribution networks allows for a better operation and improvement of the reliability indices of the system. Control devices (used to reconfigure the feeders) are placed in distribution networks to obtain an optimal operation strategy to facilitate power supply restoration in the case of a contingency. Protective devices (used to isolate faults) are placed in distribution systems to improve the reliability and continuity of the power supply, significantly reducing the impacts that a fault can have in terms of customer outages, and the time needed for fault location and system restoration. This paper presents a novel technique to optimally place both control and protective devices in the same optimisation process on radial distribution feeders. The problem is modelled through mixed integer non-linear programming (MINLP) with real and binary variables. The reactive tabu search algorithm (RTS) is proposed to solve this problem. Results and optimised strategies for placing control and protective devices considering a practical feeder are presented. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Bolted joints are a form of mechanical coupling largely used in machinery due to their reliability and low cost. Failure of bolted joints can lead to catastrophic events, such as leaking, train derailments, aircraft crashes, etc. Most of these failures occur due to the reduction of the pre-load, induced by mechanical vibration or human errors in the assembly or maintenance process. This article investigates the application of shape memory alloy (SMA) washers as an actuator to increase the pre-load on loosened bolted joints. The application of SMA washer follows a structural health monitoring procedure to identify a damage (reduction in pre-load) occurrence. In this article, a thermo-mechanical model is presented to predict the final pre-load achieved using this kind of actuator, based on the heat input and SMA washer dimension. This model extends and improves on the previous model of Ghorashi and Inman [2004, "Shape Memory Alloy in Tension and Compression and its Application as Clamping Force Actuator in a Bolted Joint: Part 2 - Modeling," J. Intell. Mater. Syst. Struct., 15:589-600], by eliminating the pre-load term related to nut turning making the system more practical. This complete model is a powerful but complex tool to be used by designers. A novel modeling approach for self-healing bolted joints based on curve fitting of experimental data is presented. The article concludes with an experimental application that leads to a change in joint assembly to increase the system reliability, by removing the ceramic washer component. Further research topics are also suggested.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Studies has been reported a significant incidence of chipping of the feldspathic porcelain veneer in zirconia-based restorations. The purpose of this study was to compare the three-point flexural strength (MPa), Weibull parameters, Vickers hardness (VHN) and Vickers indentation fracture toughness (MPa/mm(1/2)) in feldspatic porcelains for metal and for zirconia frameworks. Bar specimens were made with the porcelains e.MaxCeram (EM) and VitaVM9 (V9) for zirconia core, and Duceragold (DG) and VitaVMK95 (VK) for metal core (n = 15). Kruskal-Wallis and Dun test were used for statistical analysis. There was no significant difference (p=0.31) among the porcelains in the flexural strength (Median = 73.2; 74.6; 74.5; 74.4). Weibull calculation presented highest reliability for VK (10.8) followed by em (7.1), V9 (5.7) and DG (5.6). Vickers hardness test showed that em (536.3), V9 (579.9) and VK (522.1) had no difference and DG (489.6) had the lowest value (p<.001). The highest fracture toughness was to VK (1.77), DG (1.58) had an intermediate value while V9 (1.33) and em (1.18) had the lowest values (p<.001). Despite of the suitable flexural strength, reliability and high hardness, the porcelains used to zirconia-based fixed dental prostheses showed lower fracture toughness values.