14 resultados para Relays

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

10.00% 10.00%

Publicador:

Resumo:

An adaptive scheme is shown by the authors of the above paper (ibid. vol. 71, no. 2, pp. 275-276, Feb. 1983) for continuous time model reference adaptive systems (MRAS), where relays replace the usual multipliers in the existing MRAS. The commenter shows an error in the analysis of the hyperstability of the scheme, such that the validity of this configuration becomes an open question.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work the problem of defects location in power systems is formulated through a binary linear programming (BLP) model based on alarms historical database of control and protection devices from the system control center, sets theory of minimal coverage (AI) and protection philosophy adopted by the electric utility. In this model, circuit breaker operations are compared to their expected states in a strictly mathematical manner. For solving this BLP problem, which presents a great number of decision variables, a dedicated Genetic Algorithm (GA), is proposed. Control parameters of the GA, such as crossing over and mutation rates, population size, iterations number and population diversification, are calibrated in order to obtain efficiency and robustness. Results for a test system found in literature, are presented and discussed. © 2004 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an interactive simulation environment for distance protection, developed with ATP and foreign models based on ANSI C. Files in COMTRADE format are possible to generate after ATP simulation. These files can be used to calibrate real relays. Also, the performance of relay algorithms with real oscillography events is possible to assess by using the ATP option for POSTPROCESS PLOT FILE (PPF). The main purpose of the work is to develop a tool to allow the analysis of diverse fault cases and to perform coordination studies, as well as, to allow the analysis of the relay's performance in the face of a real event. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrical energy is present in the lives of all people and is extremely important that it be delivered to end users with plenty of quality, safety and low costs. The electric power substations are responsible for transmission and distribution of electricity generating sources to consumers, and with technological advances and the subsequent automation of same, the electricity began to be delivered with greater continuity and reliability. Protection systems in substations are largely responsible for making the electricity reaches the final consumer with quality, since their function is to prevent the spread of any type of failure occurred at any point of transmission to the load centers. These systems consist primarily by the current transformers and potential, by the protective relays and circuit breakers and switchgear. The processors send the necessary data to the relays and, if those detect any abnormality in the system, operate the opening command of the branch circuit breakers to isolate where the fault. Therefore, it is essential to better understand the operation of such equipment, as well as the overall system. This work aims to study the main substation equipment, current transformers and potential and, especially, protection relays, in order to obtain the advantages that automated systems can provide

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrical installations in industries involving high currents and voltages considered. On the other side is the common appearance of electrical failures, caused by human error, defects in electrical equipment or electrical installation aging itself. These failures are varied, those with the highest rate of occurrence and cause much damage to electrical installations, are overcurrent and overvoltage. Therefore there is a need to project a system that can detect and minimize possible effects caused by faults in electrical installations industries. Protection systems in electric industries emerge as an alternative to control especially voltage and current magnitudes. Engineered based on the functions of the relays, protection systems are an indispensable tool for any industrial substation. But the project of such systems becomes increasingly more complex, due to technological development. Electrical equipment not develop at the same speed that the protective devices (relays), making it indispensable knowledge of integration of technologies

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the growth of the demand on electric energy in the last decades, the urban distribution and transmission systems have experienced a bigger necessity to improve on the substations, the automation procedures and techniques on the operation maneuvers of such systems, in a sense that better attends the quality levels, availability, continuity and operational reliability. In this way, the objective of the present paper is to perform a study of protection and control on an electrical industrial system involving the procedures of digitizing and maneuvers automatism utilizing operational techniques and other pertinent information used in a typical high-voltage Industrial Electrical System. Analysis were made on short-circuits to specify the main components of the 138 [kV] substation, in addition, there were used digital MiCOM relays to make the protection of the present elements. With that, a program was developed to allow the user to monitor the condition of circuit-breakers through a supervision screen being able to simulate some kinds of faults, as well as observing the characteristics of each device. This way, the importance of having a fast and reliable system that ensures the equipment’s protection and the industrial process continuity due to faults on the electrical system is noticeable. It’s important to highlight that all this digitizing was mainly favored by the development of digital technology on the last years, mainly on microelectronics, also with the appearance of supervision gadgets allowing the development of complex systems in supervision and electric energy control

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)