13 resultados para Rectangular Pressure Pulse

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. We sought to establish an anesthetic protocol to evaluate the hemodynamic, metabolic, and electrolytic changes after graft reperfusion in pigs undergoing orthotopic intestinal transplant (ITX).Methods. Fifteen pigs were distributed into two groups: GI (n = 6), without immunosuppression, and GII (n = 9), immunosuppressed before surgery with tacrolimus (0.3 mg/kg). The animals were premedicated at 1 hour before surgery with IM acepromazine (0.1 mg/kg), morphine (0.4 mg/kg), ketamine (10 mg/kg), and atropine (0.044 mg/kg IM). Anesthesia induction used equal proportions of diazepam and ketamine (0.1-0.15 mL/kg/IV) and for maintenance in IV infusion of xylazine (1 mg/mL), ketamine (2 mg/mL), and guaiacol glyceryl ether 5% (50 mg/mL), diluted in 250 mL of 5% glucose solution. In addition, recipient pigs were treated with isofluorane inhalation. Heart rate (HR), systolic (SAP), mean (MAP), and diastolic (DAP) arterial pressure, pulse oximetry, respiratory frequency (f), capnography, body temperature (T), blood gas analysis (pH, PaCO(2), PaO(2), base excess, BE; HCO(3)(-), SatO(2)), serum potassium (K), calcium (Ca), sodium, hematocrit (Hct), and glucose (Glu) were measured at four times; MO: after incision (basal value); M1: 10 minutes before reperfusion; and M2 and M3: 10 and 20 minutes after graft reperfusion.Results. All groups behaved in a similar pattern. There was significant hypotension after graft reperfusion in GI and GII (M2 = 56.2 +/- 6.4 and M3 = 57.2 +/- 8.3 mm Hg and M2 = 65.7 +/- 10.2 and M3 = 67.8 +/- 16.8 mm Hg, respectively), accompanied by elevated HR. The ETCO(2) was elevated at M2 (42 mm Hg) and M3 (40 mm Hg). Metabolic acidosis was observed after reperfusion, with significant increase in K levels.Conclusion. The anesthetic protocol for donors and recipients was safe to perform the procedure, allowing control of hemodynamic and metabolic changes after reperfusion without differences regarding immunosuppression.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The stair-climbing test (SCT) is considered a submaximal test of simple implementation and easy access, which assesses the individual’s functional capacity. Although widely used in surgical patients, there is no standardization regarding the height of the stair and verbal stimulus. Objectives: It was determine if verbal stimulus changes the stair-climbing time (SCt) in individuals over 50 years-old. We compared oxygenation, blood pressure, pulse, respiratory rate and Borg scale between SCT performed with and without stimulation. Methods: We evaluated individuals with ages greater than 50 years-old that performed two STC (with and without verbal stimulation), in the stair with 44 steps, achieving 7.04 m in height and recording the time to climb the stair. The systolic blood pressure (SBP) and the diastolic blood pressure (DBP), respiratory rate (RR), pulse, oxygen saturation (SpO2 ) and Borg scale were evaluated before and after the tests. The time in the SCT with and without stimulation were compared using the Student test-t and the other variables were compared using the ANOVA test (p<0.05). Results: The average age was 59.75±6,40 years old in the 21 evaluated individuals. The time in the SCT without stimulus was significantly higher than the one with stimulus. The SBP, pulse, RR and Borg scale were significantly increased when compared to the SCT with and without stimulus. Oxygenation and DBP didn´t have significant differences at any time of the study. Conclusions: The time in the SCT was lower when performed with verbal stimulus. The SBP, pulse, RR and Borg scale changed significantly after the SCT with and without stimulus, remarking that this change was greater in the SCT with stimulus.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The phenomenon of electrical degradation in ZnO varistors was studied by application of high-intensity current pulses. A wave shape of 8 X 20-mu-s and rectangular waves of 1 and 2 ms were used. The degradation was estimated by reference electric-field variation and by Schottky voltage barrier deformation. The results showed that current pulses reduce both the height and the width of the barrier voltage. It was also observed that the donor density N(d) did not change but the surface states density N(s) decreased with degradation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this paper is to present a generalized analytical-numerical model of the internal flow in heat pipes. The model formulation is based on two-dimensional formulation of the energy and momentum equations in the vapour and liquid regions and also in the metallic tube. The numerical solution of the model is obtained by using the descretization scheme LOAD and the SIMPLE numerical code. The flow fields, as well as the pressure fields, for different geometries were obtained and discussed. Copyright © 1996 Elsevier Science Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work analyzes an active fuzzy logic control system in a Rijke type pulse combustor. During the system development, a study of the existing types of control for pulse combustion was carried out and a simulation model was implemented to be used with the package Matlab and Simulink. Blocks which were not available in the simulator library were developed. A fuzzy controller was developed and its membership functions and inference rules were established. The obtained simulation showed that fuzzy logic is viable in the control of combustion instabilities. The obtained results indicated that the control system responded to pulses in an efficient and desirable way. It was verified that the system needed approximately 0.2 s to increase the tube internal pressure from 30 to 90 mbar, with an assumed total delay of 2 ms. The effects of delay variation were studied. Convergence was always obtained and general performance was not affected by the delay. The controller sends a pressure signal in phase with the Rijke tube internal pressure signal, through the speakers, when an increase the oscillations pressure amplitude is desired. On the other hand, when a decrease of the tube internal pressure amplitude is desired, the controller sends a signal 180° out of phase.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Hypertension is the most prevalent comorbidity after heart transplantation (HT). Exercise training (ET) is widely recommended as a key non-pharmacologic intervention for the prevention and management of hypertension, but its effects on ambulatory blood pressure (ABP) and some mechanisms involved in the pathophysiology of hypertension have not been studied in this population. The primary purpose of this study was to investigate the effects of ET on ABP and arterial stiffness of HT recipients.METHODS: 40 HT patients, randomized to ET (n = 31) or a control group (n = 9) underwent a maximal graded exercise test, 24-hour ABP monitoring, and carotid-femoral pulse wave velocity (PWV) assessment before the intervention and at a 12-week follow-up assessment. The ET program was performed thrice-weekly and consisted primarily of endurance exercise (40 minutes) at similar to 70% of maximum oxygen uptake (Vo(2MAX))RESULTS: The ET group had reduced 24-hour (4.0 +/- 1.4 mm Hg, p < 0.01) and daytime (4.8 +/- 1.6 mm Hg, p < 0.01) systolic ABP, and 24-hour (7.0 +/- 1.4 mm Hg, p < 0.001) daytime (7.5 +/- 1.6 mm Hg, p < 0.001) and nighttime (5.9 +/- 1.5 mm Hg, p < 0.001) diastolic ABP after the intervention. The ET group also had improved Vo(2MAX) (9.7% +/- 2.6%, p < 0.001) after the intervention. However, PWV did not change after ET. No variable was changed in the control group after the intervention.CONCLUSIONS: The 12-week ET program was effective for reducing ABP but not PWV in heart transplant recipients. This result suggesfs that endurance ET may be a tool to counteract hypertension in this high-risk population. (C) 2015 International Society for Heart and Lung Transplantation. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT) and microtensile bond strength (μTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)(A) was observed in 140 mJ and without SPP. For μTBS, the highest mean (33.4 ± 4.15 MPa)(A) was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and μTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the μTBS values.