66 resultados para Rating of Employees

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aims of this study were (a) to assess the ability of the rating of perceived exertion (RPE) to predict performance (i.e. number of vertical jumps performed to a fixed jump height) of an intermittent vertical jump exercise, and (b) to determine the ability of RPE to describe the physiological demand of such exercise. Eight healthy men performed intermittent vertical jumps with rest periods of 4, 5, and 6s until fatigue. Heart rate and RPE were recorded every five jumps throughout the sessions. The number of vertical jumps performed was also recorded. Random coefficient growth curve analysis identified relationships between the number of vertical jumps and both RPE and heart rate for which there were similar slopes. In addition, there were no differences between individual slopes and the mean slope for either RPE or heart rate. Moreover, RPE and number of jumps were highly correlated throughout all sessions (r=0.97-0.99; P0.001), as were RPE and heart rate (r=0.93-0.97; P0.001). The findings suggest that RPE can both predict the performance of intermittent vertical jump exercise and describe the physiological demands of such exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The present study aimed to examine the reproducibility of heart rate (HR) and rating of perceived exertion (RPE) values obtained during different incremental treadmill tests. Equipment and methods Twenty male, recreational, endurance-trained runners (10-km running pace: 10–15 km·h−1) performed, in a counterbalanced order, three continuous incremental exercise tests with different speed increments (0.5 km·h−1, 1 km·h−1 and 2 km·h−1). Thereafter, each participant performed the three tests again, maintaining the same order as before. The reproducibility of the HR and RPE values were analyzed for all protocols during submaximal intensities (8, 10, 12, and 14 km·h−1). In addition, it was examined the reproducibility of maximal HR (HRmax) and peak RPE (RPEpeak). Results The variability of both the HR and RPE values showed a tendency to decrease over the stages during the incremental test and was not or slightly influenced by the incremental test design. The HR at 14 km·h−1 and HRmax presented the highest reproducibility (CV < 2%). In contrast, the submaximal RPE values showed higher variability indices (i.e., CV > 5.0%). In conclusion, the HR values were highly reproducible during the stages of the incremental test, in contrast to the RPE values that presented limited reproducibility.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Biofertilizers generated from the anaerobic and aerobic digestion of cattle manure, known as Bio1 and Bio2, respectively, were studied with regard to their microbial composition and effect on the mycelial growth of Phyllosticta citricarpa, the causal agent of citrus black spot (CBS). Two field experiments were conducted to determine the biofertilizer's potential (Bio1) in controlling CBS (2001/2002 and 2002/2003 crops). It was observed that the greatest number of microorganisms was found in the aerobically produced biofertilizer. Bio2 did not inhibit the mycelial growth of P. citricarpa. Mycelial growth of P. citricarpa was inversely proportional to the Bio1 biofertilizer concentration. In the 2001/2002 cropping season, the Biol effect in controlling CBS was directly proportional to its concentration, at the rate of 0 (healthy fruit), with R-2 = 0.88. Biol had a significant effect in controlling CBS, at a concentration of 10%, during the 2001/2002 cropping season, with DI values of 0.246 and 0.229 for the. 10 and 20% doses, respectively, compared to DI of 0.329 for the control. A directly proportional effect of the biofertilizer concentration on the percentage of fruits with a rating of zero was. also observed in the 2002/2003 cropping season, with R-2 = 0.48. However, even at doses higher than in the preceding cropping season, the biofertilizer was less effective, possibly due to a higher occurrence of the disease. Copper oxychloride and combined applications of copper oxychloride and carbendazim plus mancozeb controlled the disease. The possibility of using the biofertilizer as a protective biofungicide to replace copper oxychloride, especially in organic agriculture, should be explored. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. The aim of this study was to analyze the relationships between the rate of perceived exertion (RPE) of a whole exercise session (RPE-S) and objective measures of exercise intensity during a karate training session.Methods. Eight well-trained karate athletes performed a single training session involving basic karate techniques and sparring. Heart rate (HR) was continuously monitored, while blood lactate ([lac]13) and rating of perceived exertion using the Borg's 6-20 scale were taken each 10-min during exercise. Athletes were also asked to rate their RPE-S using a modified CR-10 scale 30-min after exercise.Results. Significant relationships (P<0.05) were found between RPE-S and mean values of %HRmax (r(p) = 0.91), %HR reserve (r(p) = 0.87), [lac]b(r(p) = 0.96), and RPE (r(p) = 0.78) during the session, but not between RPE-S and the duration of exercise bout (r(s) = 0.28; P > 0.05). RPE-S was also significantly related (P < 0.05) to percentage of time sustained under ventilatory thresold (VT) (r(p) = 0.96), between VT and respiratory compensation point (RCP) (r(p) = 0.93) and above RCP (r(p) = 0.96).Conclusion. These results suggest RPE-S to be a valid tool for assessing interindividual variations in global exercise intensity during karate training. (C) 2010 Elsevier Masson SAS. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of preferred and nonpreferred music on exercise distance, Heart Rate (HR), and Rating of Perceived Exertion (RPE) during continuous cycling exercise performed at high intensity Fifteen participants performed five test sessions During two sessions, they cycled with fixed workload on ergometer to determine the Critical Power (Cl') intensity Then, they performed three more sessions cycling at CP intensity listening to Preferred Music, listening to Nonpreferred Music, and No Music The HR responses in the exercise sessions did not differ among all conditions However, the RPE was higher for Nonpreferred Music than in the other conditions The performance under Preferred Music (9 8 +/- 4 6km) was greater than under Nonpreferred Music (7 1 +/- 3 5km) conditions Therefore, listening to Preferred Music during continuous cycling exercise at high intensity can Increase the exercise distance, and individuals listening to Nonpreferred Music can perceive more discomfort caused by the exercise

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Controversy still exists concerning the potential ergogenic benefit of caffeine (CAF) for exercise performance. The purpose of this study was to compare the effects of CAF ingestion on endurance performance during exercise on a bicycle ergometer at two different intensities, i.e., approximately 10% below and 10% above the anaerobic threshold (AT). Eight untrained males, non-regular consumers of CAF, participated in this study. AT, defined as the intensity (watts) corresponding to a lactate concentration of 4 mM, was determined during an incremental exercise test from rest to exhaustion on an electrically braked cycle ergometer. on the basis of these measurements, the subjects were asked to cycle until exhaustion at two different intensities, i.e., approximately 10% below and 10% above AT. Each intensity was performed twice in a double-blind randomized order by ingesting either CAF (5 mg/kg) or a placebo (PLA) 60 min prior to the test. Venous blood was analyzed for free fatty acid, glucose, and lactate, before, during, and immediately after exercise. Rating of perceived exertion and time to exhaustion were also measured during each trial. There were no differences in free fatty acids or lactate levels between CAF and PLA during and immediately after exercise for either intensity. Immediately after exercise glucose increased in the CAF trial at both intensities. Rating of perceived exertion was significantly lower (CAF = 14.1 ± 2.5 vs PLA = 16.6 ± 2.4) and time to exhaustion was significantly higher (CAF = 46.54 ± 8.05 min vs PLA = 32.42 ± 14.81 min) during exercise below AT with CAF. However, there was no effect of CAF treatment on rating of perceived exertion (CAF = 18.0 ± 2.7 vs PLA = 17.6 ± 2.3) and time to exhaustion (CAF = 18.45 ± 7.28 min vs PLA = 19.17 ± 4.37 min) during exercise above AT. We conclude that in untrained subjects caffeine can improve endurance performance during prolonged exercise performed below AT and that the decrease of perceived exertion can be involved in this process

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. To use the Pediatric Rheumatology International Trials Organization (PRINTO) core set of outcome measures to develop a validated definition of improvement for the evaluation of response to therapy in juvenile systemic lupus erythematosus (SLE).Methods. Thirty-seven experienced pediatric rheumatologists from 27 countries, each of whom had specific experience in the assessment of juvenile SLE patients, achieved consensus on 128 patient profiles as being clinically improved or not improved. Using the physicians' consensus ratings as the gold standard measure, the chi-square, sensitivity, specificity, false-positive and false-negative rates, area under the receiver operating characteristic curve, and kappa level of agreement for 597 candidate definitions of improvement were calculated. Only definitions with a kappa value greater than 0.7 were retained. The top definitions were selected based on the product of the content validity score multiplied by its kappa statistic.Results. The definition of improvement with the highest final score was at least 50% improvement from baseline in any 2 of the 5 core set measures, with no more than 1 of the remaining worsening by more than 30%.Conclusion. PRINTO proposes a valid and reproducible definition of improvement that reflects well the consensus rating of experienced clinicians and that incorporates clinically meaningful change in core set measures in a composite end point for the evaluation of global response to therapy in patients with juvenile SLE. The definition is now proposed for use in juvenile SLE clinical trials and may help physicians to decide whether a child with SLE responded adequately to therapy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper it is proposed a novel hybrid three-phase rectifier capable to achieve high input power factor (PF), and low total harmonic distortion in the input currents (THDI). The proposed hybrid high power rectifier is composed by a standard three-phase 6-pulses diode rectifier (Graetz bridge) with a parallel connection of single-phase Boost rectifiers in each three-phase rectifier leg. Such topology results in a structure capable of programming the input current waveform and providing conditions for obtaining high input power factor and low harmonic current distortion. In order to validate the proposed hybrid rectifier, this paper describes its principles of operation, with detailed experimental results and discussions on power rating of the required Boost converters as related to the desired total harmonic current distortion. It is demonstrated that only a fraction of the output power is processed through the Boost converters, making the proposed solution economically viable for very high power installations, with fast pay back of the investment. Moreover, retrofitting to existing installations is also feasible since the parallel path can be easily controlled by integration with the existing de-link. A prototype rated at 6 kW has been implemented in laboratory and fully demonstrated its operation, performance and feasibility to high power applications. © 2005 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work presents a study regarding the optimization of multipulse converters. A general expression for the connection (Δ or Y) for both 12 and 18-pulses is obtained and describes the output voltages on the secondary windings, depending on the voltage reference from the primary. These generalized expressions allows choosing different ratios between input and output voltages and as result an optimum operation point for the converter can be calculated. Considering Δ-connected converters the optimum point occurs when the magnetic core of the autotransformer processes 18% and 17% of the output power for 12 and 18-pulses, respectively. For Y-connected converters the optimum point occurs when the kVA rating is 13% and 18% for 12 and 18-pulses, respectively. Based on these results magnetic elements can be calculated and designed leading to a great weight and volume reduction and also to lower costs and losses. Finally an analysis is made to improve the kVA rating of the transformers for 12 and 18 pulses converters. © 2009 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results are also presented in this paper. © 2009 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)