617 resultados para Radiografia : Anatomia

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The maxillary lateral incisor has a very peculiar and internal morphology that can be influenced by the its external anatomy such as supernumerary roots and ruts deep root, which often hinders an effective endodontic treatment. Generally, this tooth have a single root with one root canal, but teeth with two to four channels can be found. The main canal can present ramifications such as accessory canals, laterals, collaterals, recorrents and apical deltas. All this factors interfere directally on endodonthics treatment. The objective of this work is a study of the internal anatomy of the maxillary lateral incisors by digital and conventional radiographics methods, comparing the results obteined by each method Six hundred upper lateral incisor were used in this study teeth of the collection of the Department of Anatomy ICT – UNESP. All the teeth were radiographed by vestibular face, using a digital radiographic unit(Dabi Atlante). After this step, all the teeth underwent by conventional radiographic technique(Kodak 2200) so that the results obtained were compared. To classify the channel system, it was adopted the classification of Pucci and Reig. All data obtained by digital technique were compared with those obtained in the conventional technique and were subjected to statistical analysis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plântulas de Cybistax antisyphilitica (ipê-verde), espécie arbórea que ocorre no Estado de São Paulo, Brasil, foram estudadas morfoanatomicamente e citogeneticamente. As plântulas são eudicotiledôneas, fanerocotiledonares e epigéias. Suas sementes apresentam alas hialinas, assimétricas e de textura papirácea. A raiz é axial com tecido epidérmico irregular. O hipocótilo é verde, glabro e apresenta os elementos do xilema em diferenciação. Os cotilédones são verdes, foliáceos, reniformes, com mesofilo heterogêneo, epiderme pilosa e feixes vasculares colaterais. Os eófilos são glabros, peciolados, de filotaxia oposta, dorsiventrais, hipoestomáticos e possuem mesofilo heterogêneo e assimétrico. Não há diferenças anatômicas significativas entre os eófilos e os metáfilos. O sistema vascular do pecíolo dos metáfilos dispõe-se em forma de ferradura. A espécie apresenta número cromossômico mitótico 2n = 40 com comprimento cromossômico geral médio de 1,042 µm ± 0,140 e amplitude variando de 0,58 µm até 1,60 µm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Durante o processo de envelhecimento, as sementes sofrem alterações degenerativas que influenciam o seu potencial fisiológico. Entre estas alterações podem estar as modificações anatômicas nas camadas celulares da testa da semente. Objetivou-se, com este trabalho, verificar a relação entre a anatomia da testa de sementes de soja, cultivar Monsoy 8400 e a germinação, após o envelhecimento acelerado, pelo fato da testa apresentar um papel fundamental na conservação do potencial fisiológico das sementes. As sementes foram envelhecidas a 42ºC e 100% UR do ar por períodos de zero, 24, 48, 72 e 96 horas. Avaliaram-se os teores de água e a germinação, posteriormente à secagem, seções transversais da testa de 10 sementes de cada tratamento foram eletromicrografadas, com microscópio eletrônico de varredura,,observando-se as camadas das células paliçádicas, ampulhetas e parenquimáticas A germinação declinou com o aumento dos períodos de envelhecimento. Houve redução da espessura das camadas da testa nos períodos de 48, 72 e 96 horas deste processo. Observou-se que, principalmente, para os períodos de envelhecimento de 72 e 96 horas, que as células da camada hipodérmica apresentaram um aspecto de colapso, sendo este acentuado para o período de 96 horas. A redução da espessura das camadas sugere a ocorrência de um colapso das células que compõem tais camadas, sendo um fator causador da redução do potencial germinativo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os reguladores de crescimento podem retardar o desenvolvimento vegetativo das plantas de gramas e, assim, reduzir a frequência de cortes; contudo, existem poucas informações referentes aos efeitos desses produtos sobre as estruturas da anatomia foliar. Dessa forma, o presente trabalho teve por objetivo avaliar os efeitos da aplicação sequencial de duas doses de trinexapac-ethyl sobre a anatomia foliar das espécies de gramas São Carlos (Axonopus compressus), Batatais (Paspalum notatum), Santo Agostinho (Stenotaphrum secundatum) e Esmeralda (Zoysia japonica). Os tratamentos utilizados foram constituídos de duas aplicações sequenciais de trinexapac-ethyl nas doses de 56,5+56,5 e 113,0+113,0 g ha-1; além de uma testemunha sem aplicação, para cada espécie avaliada. Os gramados foram cortados à altura de 3 cm, com auxílio de um aparador de grama motorizado, e, em seguida, foram realizadas as aplicações dos tratamentos. Após 20 dias da primeira aplicação de trinexapac-ethyl, as parcelas foram novamente aparadas à altura de 3 cm e foi realizada a segunda aplicação dos tratamentos. O delineamento experimental utilizado foi o de blocos ao acaso, com quatro repetições. Aos 70 dias após a segunda aplicação dos tratamentos, foram realizadas as amostragens do material foliar, para as quatro espécies estudadas. Os dados das variáveis quantitativas foram submetidos ao teste estatístico multivariado de análise de componentes principais. Os resultados evidenciaram a formação de três e dois grupos principais, para os caracteres da região da quilha (nervura mediana) e da região da asa (situada entre a nervura mediana e a margem do limbo foliar), respectivamente. de modo geral, em cada formação dos agrupamentos, os tratamentos com trinexapac-ethyl apresentaram maior similaridade entre si, em relação às respectivas testemunhas. Conclui-se que a aplicação sequencial de trinexapac-ethyl alterou algumas estruturas anatômicas da região da quilha e da asa do limbo foliar das espécies de gramas estudadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional radiographic technique using industrial radiographic films is with the days finishing. The Digital Radiography is taking place in several sectors, e.g., the medical, aerospace, security, automotive, etc. In addition to representing a technological trend, it has been demonstrated that digital radiography offers a series of benefits in terms of productivity, sensitivity, environmental aspects, image treatment tools, cost reduction, etc. If one weld seam to be inspected is from a serried product, as example a pipe, the best option to be implemented is the Flat Panel Detector with this equipment is possible to reduce the obtaining digital radiographic images in place of films and reducing the inspection cycle time due to its high degree of automation. In the experiments described in this paper this new technique was tested and the results were compared with those obtained by the conventional radiography. The welded specimens were prepared using the submerged-arc welding process and small artificial cracks of the most varied dimensions, present in the specimens, were used to establish a comparison of the sensitivities presented by the techniques employed After conducting several experiments, the digital method presented the highest sensitivity to the wire-type Image Quality Indicator (IQI) and in the detection of small defects, leading to the conclusion that the use of digital radiography using the flat-panel detector offers advantages over the conventional technique [1, 2]. This work was carried out based on the API 5L Edition 2004 [3] and ISO 3183 Edition 2007 [4] specifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entre 6.316 necropsias realizadas, no período de 1969 a 2000, no Departamento de Patologia da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista (FMB/UNESP), foram encontradas 240 necropsias com diagnóstico de tuberculose, sendo 117 registradas como doença principal (grupo tuberculose/doença principal) e 123, como doença associada (grupo tuberculose/doença associada). No grupo tuberculose/doença principal, 100% apresentavam tuberculose ativa, com 80 ocorrências em homens e 37 em mulheres e média de idade de 47,7 anos. Caquexia (37,2%) e cor pulmonale (23,7%) foram as co-morbidades mais prevalentes nesse grupo. Os pulmões estavam comprometidos em 95,7% dos casos, seguido pelos linfonodos (38,9%) e pleuras (27,1%). Os padrões morfológicos das lesões pulmonares foram: 1. miliar, 58,4%; 2. cavernas, 56,6%; 3. fibrose, 41,5%; 4. bronquiectasias, 26,5%; 5. enfisema, 19,4%; e 6. cistos, 1,7%. Cavernas foram observadas em diferentes áreas, com discreto predomínio no pulmão direito, sendo a localização apical preferencial (100%) e quase sempre bilaterais (94%). Lesões miliares, bronquiectasias e fibrose estavam distribuídas, de forma difusa e aleatória, nos pulmões. No grupo tuberculose/doença associada também houve predomínio de homens (70,8%). Nesses casos, a AIDS e o alcoolismo crônico foram as doenças principais mais freqüentes, representando 22% e 16,3%, respectivamente. Os pulmões estavam acometidos em 85,2% dessas necropsias (100% nos casos de AIDS), seguidos pelos linfonodos (31,9%) e baço (28,6%). Nossos dados corroboram a importância da necropsia no estudo e no conhecimento da tuberculose, fornecendo subsídios para uma melhor abordagem clínica e epidemiológica dessa doença em nossa região.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiography (conventional and contrasted - canalography) and audioelectrophysiologic (impedance audiometry) tests were correlated with otitis media in 12 middle ear affected and 12 healthy dogs. When comparing both diagnostic methods, it was found that the reliability in the detection of otitis media in dogs was 100% for the first and 58.3-60.0% for the latter. Thus, it was possible to attest that the impedance audiometry was the most accurate method in the identification of otitis media in dogs when compared with radiographic assessments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiografia e ultrassonografia foram avaliadas como técnicas no diagnóstico por imagem na ruptura do ligamento cruzado cranial (LCCr) em cães. Vinte e cinco cães foram submetidos à radiografia e ultrassonografia e seus resultados foram comparados aos obtidos por artrotomia (teste padrão ouro). O exame radiográfico diagnosticou corretamente a lesão em 84% (21/25) dos casos, mas 16% (4/25) apresentaram resultado falso-negativo. O exame ultrassonográfico foi capaz de diagnosticar acertadamente 76% (19/25) dos casos, e sugeriu a ruptura do LCCr nos 24% (6/25) restantes, apresentando 100% de resultados positivos. Concluiu-se que a radiografia e a ultrassonografia são ferramentas valiosas para diagnosticar casos de ruptura do LCCr em cães.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: o presente ensaio científico põe em pauta o efeito imediato da distalização unilateral de molares superiores, lançando mão do distalizador intrabucal Pendex de ação unilateral. METODOLOGIA: o estudo prospectivo foi conduzido em três pacientes na dentadura permanente madura, no estágio de adolescência, que apresentavam uma má oclusão Classe II, subdivisão. O aparelho Pendex foi instalado com a mola distalizadora de TMA, construída apenas no lado direito. A metodologia baseou-se nas radiografias panorâmicas inicial e pós-distalização para quantificar a inclinação axial mesiodistal dos molares superiores. RESULTADOS E CONCLUSÕES: os resultados mostraram que os molares do lado esquerdo mantiveram sua inclinação mesiodistal inicial, sugerindo ancoragem, enquanto os molares do lado direito foram inclinados para distal, à semelhança do que ocorre com a distalização simétrica dos molares superiores, obtida com o aparelho Pendex convencional. Os primeiros molares foram inclinados 11,5º, enquanto os segundos molares foram inclinados 21º para distal.