66 resultados para Radioactive waste disposal.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundwaters and surface waters from an area of treatment of sand for industrial purposes at Analandia municipality, nearly in the center of Sao Paulo State, Brazil, were chemically and isotopically analyzed with two aims: to evaluate if the anthropogenic activities that has taken place for the last 6 years is affecting the quality of the hydrological resources and to relate the hydrogeochemical behaviour of the uranium isotopes 234U and 238U with the pattern of circulation of groundwaters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A contaminated site from a downstream municipal solid waste disposal site in Brazil was investigated by using a 3D resistivity and induced polarization (IP) imaging technique. This investigation purpose was to detect and delineate contamination plume produced by wastes. The area was selected based on previous geophysical investigations, and chemical analyses carried out in the site, indicating the presence of a contamination plume in the area. Resistivity model has successfully imaged waste presence (rho < 20 Omega m), water table depth, and groundwater flow direction. A conductive anomaly (rho < 20 Omega m) outside wastes placement was interpreted as a contamination plume. Chargeability model was also able to imaging waste presence (m > 31 mV/V), water table depth, and groundwater flow direction. A higher chargeability zone (m > 31 mV/V) outside wastes placement and following conductive anomaly was interpreted as a contamination plume. Normalized chargeability (MN = m/rho) confirmed polarizable zone, which could be an effect of a salinity increase (contamination plume), and the clay presence in the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundwaters; and surface waters around two waste disposal areas at Rio Claro municipality, nearly in the center of São Paulo State, Brazil, were chemically analysed with the purpose of evaluating the influence on the water quality of the chemicals released without any care with the environment and using a prevention system for the containment of environmentally polluting substances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different geoenvironmental site investigation techniques to assess contamination from a municipal solid waste disposal site in Brazil are presented here. Superficial geophysical investigation (geoelectrical survey), resistivity piezocone penetration tests (RCPTU), soil samples collected with direct-push samplers and water samples collected from monitoring wells were applied in this study. The application of the geoelectrical method was indispensable to identify the presence and flow direction of contamination plumes (leachate) as well as to indicate the most suitable locations for RCPTU tests and soil and water sampling. Chemical analyses of groundwater samples contributed to a better understanding of the flow of the contaminated plume. The piezocone presented some limitations for tropical soils, since the groundwater level is sometimes deeper than the layer which is impenetrable to the cone, and the soil genesis and unsaturated conditions affect soil behavior. The combined interpretation of geoelectrical measurements and soil and water samplings underpinned the interpretation of RCPTU tests. The interpretation of all the test results indicates that the contamination plume has already overreached the landfill's west-northwest borders. Geoenvironmental laboratory test results suggest that contamination from the solid waste disposal site has been developing gradually, indicating the need for continuous monitoring of the groundwater.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This investigation reports the results of a study realized in an area related to the development of sand mining activities, which belongs to Sibelco Mineração Ltd. The site is located around Analândia municipality, nearly in the center of São Paulo State, Brazil. Hydrochemical analyses of groundwater were realized under different periods of time, with the aim of evaluating the possibility of release of several constituents to the liquid phase, which may be a source of pollution of the surface hydrological resources and of the deeper Guarani aquifer. This is because the site is located at the recharge area of Guarani aquifer and some tributaries from Corumbataí river may also be suffering contamination, implying on the impoverishment of the water quality that are very important resources in the region, as they are extensively used for drinking purposes, among others.© 2011 WIT Press.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Urban centers have a huge demand for electricity and the growing problem of the solid waste management generated by their population, a relevant social and administrative problem. The correct disposal of the municipal solid waste (MSW) generated in cities is one of the most complex engineering problems that involves logistics, safety, environmental and energetic aspects for its adequate management. Due to a national policy of solid wastes recently promulgated, Brazilian cities are evaluating the technical and economic feasibility of incinerating the non-recyclable waste. São José dos Campos, a São Paulo State industrialized city, is considering the composting of organic waste for biogas production and mass incineration of non-recyclable waste. This paper presents a waste-to-energy system based on the integration of gas turbines to a MSW incinerator for producing thermal and electric energy as an alternative solution for the solid waste disposal in São José dos Campos, SP. A technical and economic feasibility study for the hybrid combined cycle plant is presented and revealed to be attractive when carbon credit and waste tax are included in the project income. © 2013 Elsevier Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: The purpose of this study was to identify the sources of waste generation household consisting of biological material and to investigate the knowledge presented by those responsible for the generation of waste in the home environment on the potential health risk human and environmental. Method. It is a quantitative survey performed in Parque Capuava, Santo André (SP). The questionnaire was administered by the community employers and nursing students during the consultation with nursing supervision through interview question/answer. The exclusion criteria were patients who were not in the area served by the Basic Health Unit which covers the area of Pq Capuava. The sample was consisted of 99 persons and the data collection a questionnaire was used. Results: We observed that 63.3% of people said to use disposables, with the majority (58.7%) of these use the public collection as the final destination of these materials. It was reported that 73.7% of those surveyed reported having knowledge about the risk of disease transmission. Public awareness of the importance of proper packaging and disposal of potentially hazardous household waste may contribute significantly to the preservation of human and environmental health and this procedure can be performed and supervised by professional nurses. Conclusion: We suggest implementation of workshops for community health workers and the general population in order to enhance their knowledge about the storage and disposal of potentially infectious waste generated at home, thereby reducing the potential risk of disease transmission by improper management. © 2013 Chaves et al.; licensee BioMed Central Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este trabalho objetivou caracterizar um sistema de solos, evidenciando a propriedades que possam esclarecer sua dinâmica e contribuir para a definição de critérios que condicionem a aptidão destes solos como receptores de efluentes. Trata-se de uma área experimental de estudos, contígua à Estação de Tratamento de Esgoto do município de Lins (SP), onde o efluente é gerado a partir do tratamento de esgoto por sistema de lagoas de estabilização. Os solos, situados ao longo de uma vertente com ligeira inclinação, foram caracterizados por meio de análises, morfológica, granulométrica, química, mineralógica e micromorfológica, realizadas em amostras coletadas em cinco trincheiras em toposseqüência. Os solos são desenvolvidos a partir dos sedimentos arenosos da Formação Adamantina (Grupo Bauru) e constituem um sistema Latossolo - Argissolo onde a transição Bw - Bt ocorre lateralmente do topo para a base da vertente. Foram identificadas três fases pedogenéticas nesta associação de solos. A primeira, argiluviação e adensamento de partículas, responsável pela formação dos horizontes texturais, foi superposta pelos processos de latossolização e hidromorfismo, atuantes na dinâmica atual destes solos. Análises micromorfológicas mostraram tratar-se de solos com intensa porosidade, caracterizada pelo empilhamento dos grãos do esqueleto quartzoso amplamente predominante e pelo arranjo entre os microagregados granulares. A permeabilidade é ainda favorecida pela intensa ação da mesofauna. Os solos são distróficos e compostos por caulinita e óxidos de Fe na fração argilosa. Por constituírem um sistema frágil, a disposição de quaisquer tipos de resíduos nestes solos requer o monitoramento constante de suas propriedades, tanto para a manutenção, quanto para a recuperação da qualidade desta cobertura pedológica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effects of metal bioleaching on nutrient solubilization, especially nitrogen and phosphorous, from anaerobically-digested sewage sludge were investigated in this work. The assessment of the sanitary quality of the anaerobic sludge after bioleaching was also carried out by enumerating indicator (total coliforms, fecal coliforms, and fecal streptococci) and total heterotrophic bacteria. The experiments of bioleaching were performed using indigenous sulphur-oxidizing bacteria (Thiobacillus spp.) as inoculum and samples of anaerobically-digested sludge. Nitrogen and phosphorous solubilization from sewage sludge was assessed by measuring, respectively, the concentration of Total Kjeldahl Nitrogen, ammonia, nitrate/nitrite, and soluble and total phosphorous before and after the bioleaching assays. At the end of the experiment, after 4 days of incubation (final pH of 1.4), the following metal solubilization yields were obtained: zinc, 91%; nickel, 87%; copper, 79%; lead, 52%; and chromium, 42%. As a result of sludge acidification, the viable counts of selected indicator bacteria were decreased to below the detection limit (4 × 103 cfu 100 ml-1), followed by an increase in the mineral fraction of nitrogen (from 6 to 10%) and in the soluble fraction of phosphorous (from 15 to 30%). Although some loss of sludge nutrients can occur during solid-liquid separation following bioleaching, its beneficial effects as metal removal and reduction of pathogenic bacteria are sufficient to consider the potential of this treatment before sludge disposal onto agricultural fields.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Water samples (24 untreated water, 12 treated water and 24 served water) used in different stages of the slaughter process were examined to identify a possible source of pathogenic mycobacteria. The isolates were identified based on microscopy, morphological and biochemical features, mycolic acid analysis and molecular method - PCR-restriction-enzyme analysis. Eighteen mycobacterial strains were isolated from 60 water samples: 11 from untreated water, 5 from treated water and 2 from served water. All mycobacteria isolated were identified as Mycobacterium gordonae and showed the following PRA genotypes: III (27.8%), IV (38.9%) and V (33.3%).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Liners were proposed as subsoil contamination protection devices for waste disposal sites. In the rural environment, they can be used to construct pond bottoms for liquid waste treatment, but the construction needs to be quick and cheap. A good technical solution for these situations is the use of local soil compacted with low quantities of cement or lime, obtaining good properties for this purpose. These barriers need special care about their contraction behavior which may compromise its use. This work shows the results of contraction tests in sandy soil specimens and others stabilized with lime and with cement. Soil structure changes during cure time were checked using electronic scan microscopy. Results show maximum soil contraction of 0.648% for specimen with 14 days cure process. After twenty eight days of cure the contraction values were lower than 0.5%, which classifies the material as of low contraction. Electronic scan image shows significant material structure alteration up to seven days cure. Results show that studied mixtures had appropriate contraction behavior for liner usage.