142 resultados para Qualidade do Ar Interior
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Persistent Organic Pollutants (POPs) are chemical substances extraordinarily toxic and persistent in the environment. Due to these properties, POPs are targets of the Stockholm Convention which aims to provide means to eliminate production and use by encouraging the reduction and, where possible, eliminating the release of these contaminants to the environment. One of the articles of this _Convention aims to assess the basal levels of such substances in the environment to monitor both the reduction of release to the environment, and to assess human exposure, using analyzes of milk and air for example. Although efforts to control POPs production and release to the environment have been made, data about their levels in Brazil are still scarce, mainly in the atmosphere or indoor environment. Considering the permanence of people inside its house, this study presents a method for POP extraction from XAD-2 sorbent employed in indoor air sampling, with identification and quantification by GC-ECD. GC-ECD linear range of the studied analytes, congeners of polychlorinated biphenyls (PCB) (28, 52, 101, 118, 138, 153 and 180), DDTs and their metabolites (DDDs, DDEs) and endosullan (isomers c - and 13 - and metabolite endosulfan sulfate) ranged between 0.5 and 16.0 ng mL-I with r2 > 0.967. The method developing consist of selecting the extraction solvent system by agitation (90 rpm, 1 hour) with n-hexan,e (2 mL) or n-hexane:acetone (1:1, v/v) (2 mL), concentration the extract with a gentle N2 stream, and evaluation of breakthrough with passage or air through the fortified XAD-2 cartridge before extraction, employing a low volume air suction pump (Pump Model 224 universal-PCXR8; 5-5000 mL min-1, SKC Inc., Eighty Four, PA, USA), Calibrator Dry-Cal DC-Lite (BIOS, Butler, NJ, USA)). Two fortification levels were employed, 15 and 30 ng. After selecting n-hexane as extraction solvent, with accuracy and precision ranging...
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O desenvolvimento e implantação de sistemas de gestão da qualidade e o uso de programas e ferramentas da qualidade são algumas das opções mais utilizadas pelos gestores para aumentar a competitividade de suas empresas. Nesse contexto, o objetivo deste artigo é apresentar o resultado de uma pesquisa tipo survey em que se verificaram e analisaram as principais características do processo de certificação ISO 9001, seus benefícios, suas dificuldades e quais programas e ferramentas da qualidade são utilizados em 236 empresas do interior do Estado de São Paulo. A pesquisa revelou que a certificação ISO 9001 gera benefícios significativos às organizações, tais como: melhoria dos processos internos e nos seus produtos; aumento da satisfação dos clientes; diminuição do número de não conformidades e de devoluções; aumento da produtividade e do lucro; melhoria no gerenciamento dos recursos e valorização da imagem da empresa no mercado. Ela também ratificou a importância da utilização dos programas e ferramentas da qualidade como forma de as empresas se adequarem melhor aos requisitos da norma ISO 9001. As dificuldades de desenvolvimento e implantação desses sistemas não se confirmaram para a amostra pesquisada. Apenas a resistência à mudança, dentre todas apresentadas, mereceu destaque para os pesquisados.
Resumo:
Microbial contamination of an enclosed area may come from outside or be generated within the area itself. In the study described here, bioaerosol levels in hospital air were quantified and related to those found in the air outside, taking into account some of the environmental variables that affect air quality, such as the number of occupants of a room and the type of ventilation. Airborne bacteria were collected for five minute by blowing air at 500 L min -1 in high speed jets on to the surface on plates culture in a single-stage bioaerosol impactor. The mean viable count of bacteria in the air outside in the hospital, São Paulo State, was 77 ± 4 CFU m -3, while in the air inside the hospital it was 302 ± 260 CFU m-3. The operating theatre was the only space sampled with a controlled environment and, after orthopedic surgery, it had the highest bioaerosol count recorded (867 ± 482 CFU m-3). In the enclosed environments, nine bacterial species were identified. Despite the difficulty in establishing precise numbers of bacteria in the bioaerosols in hospital environments, the values obtained demonstrate a need to instigate suitable programs to keep the microbial density low in these environments, and eliminate microorganisms presenting a significant risk to their occupants. It is also recommended that such programs include the monitoring of hospital air, with the aim of defining standards for acceptable numbers of bacteria in the bioaerosol.
Resumo:
Pós-graduação em Geografia - IGCE
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Our twenty-first century society and the rhythm of life and work we have to face in our daily routine compel us to spend most of our lifetime in closed environments, in our houses, educational institutions, hospitals, airports, amongst as many others. The study of the air quality in internal environments (IAQ) is very important for monitoring people’s health effects and their environmental comfort in these locations. One essential parameter to analyze this measure is to evaluate the concentration of dispersed particulates in the air, specially focusing on those thinner particles (below the diameter of 2,5 μm), they can pose serious risks for human being because they can remain in the lungs, penetrate through the pores of our skin, amongst other harmful effects on human’s health. In this work the air quality inside the public library Profª Josina Vasques Ferrari and at Unesp public state library was evaluated, both located in Itapeva, as well as a third one, inside the Communitarian Library of the Federal University in Carlos (UFSCar) from march to may in 2012. In those environments it was analyzed if the concentration of particulates pose any real treat to the users. The equipment used for particle sampling in real time was DataRam 4 (Model DR 4000). The results given for those concentrations of particulates in both internal and external environments revealed figures within the safe standard established by the WHO (World Health Organization), from 25 to μg/m³, the only exception occurred on the fifth floor of the UFSCar library, where the average for concentration stayed at 25,30 of μg/m³
Resumo:
This paper proposes an analysis of two major polluting elements of the atmosphere of São Paulo city, carbon monoxide (CO) and sulfur dioxide (SO2). This study was performed through analysis of data on the quality of air, by means of published reports and records obtained by experiment using measuring rate monitor for CO2. Atmospheric data were collected and sorted. From this work it was possible to identify the concentration of carbon dioxide in the center of São Paulo on September 14, 2012 using the infrared gas analyzer (IRGA). From the ratios of carbon monoxide and sulfur dioxide spatially analyzed could identify major emitters by comparing records of pollutants and their origin. The analysis makes it possible to map the intensity of air pollution in urban areas, identifying the polluting elements, their issuers and thereby contributes to the current understanding of atmospheric features, bringing a geographical spatial analysis of air pollutants in São Paulo, contributing to awareness of vulnerabilities, enabling a useful tool for planning and maintenance of the urban environment related public policies
Resumo:
Air pollution is an environmental issue worldwide and frequently cause negative effects on population health and ecosystems on cities. The relationship between climate and atmospheric pollution can be used as a surrogate to the intensity of air pollution. The present and quantity of some gases can be used as indicators to air quality: particulate matter (PM), sulfur dioxide (SO2), carbon monoxide (CO), ozone (O3), and nitrogen dioxide (NO2). Among those gases, CO has its major source within the cities, where automobiles are the main emitter. But measure pollutant concentration are challenging, sometimes because the lack of good equipments due to high costs and of the large variability of models that varies in precision, way of measure and distribution of sellers. Modeling are useful when there are an intend to evaluate air pollution, its sources and evaluate scenarios. This work aims to use CAL3QHCR model developed by the U.S Environmental Protection Agency (EPA) to generate predictive surfaces of CO concentration distribution on a site within Campinas city, located in São Paulo state, Brazil. CAL3QHCR model use data urban automobile circulation to generate spatial results for CO distribution. We observed that the pollution concentration was lower on our modeling than the concentrations measured by Companhia Ambiental do Estado de São Paulo (CETESB), the main environmental company on the São Paulo state. Also the correlation between average estimates of our model and the measure by CETESB was weak, indicating that the model used on this study need to be or better parameterized, or the scale we measured of CO emissions need to be rescaled. Although the model failed to correlate to CETESB data, maybe one that explore the estimated emissions distributed within the sites to understand spatial distributions of CO on the regions. Also, the generated information can also be used to other studies, and come to be useful to explain heat island