70 resultados para Pyruvate cycling

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growing corn mixed with forage crops can be an alternative for pasture and Mulch production during relatively dry winters in tropical areas, making no-till feasible in some regions. However, little is known about nutrient dynamics in this cropping system. The objective of the present work was to evaluate K dynamics in a production system in which corn was either grown as a sole crop or mixed with Brachiaria brizantha. In the second year of the experiment, nitrogen rates ranging from 0 to 200 kg ha(-1) were applied to the system. Dry matter yields and potassium contents in the soil, as well as residues and plants were determined at corn planting and harvest. Potassium balance in the system was calculated. Corn grain yield in mixed crop responded up to 200 kg ha(-1) N. The introduction of brachiaria in the system resulted in higher amounts of straw on the soil Surface and higher K recycling. Soil exchangeable K balance showed an excess K for both N rates only in the mixed system, however, when non-exchangeable K was also included in calculations, excess K was found in both mixed and sole corn systems. Large amounts of non-exchangeable K were taken up in the system involving brachiaria, which showed a considerable capacity in recycling K, increasing its contents in the surface soil layer. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of cycling various pH demineralizing solutions on the surface hardness, fluoride release and surface properties of restorative materials (Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil). Thirty specimens of each material were made and the surface hardness measured. The specimens were randomized into five groups according to the pH (4.3; 4.6; 5.0; 5.5 and 6.2) of the demineralizing solution. The specimens were submitted to pH-cycling for 15 days. The specimens remained in the demineralizing solution for six hours and in the remineralizing solution for 18 hours. Then, the surface hardness (SH) was remeasured and the surface properties were assessed. Fluoride release was determined daily. Data from SH and the percentage of alteration in surface hardness were analyzed by analysis of variance (p < 0.05); the Kruskal-Wallis test was performed for the fluoride release results. When hardness was compared, the variation in pH led to a positive correlation for glass ionomer cements and a negative correlation for fluoride release. For polyacid-modified resin composites, a negative correlation was found with regards to fluoride release; no significant correlation was observed for hardness. Surface properties were influenced: an acidic pH led to a greater alteration, except for polyacid-modified resin composites. The pH of the demineralizing solution influenced fluoride release from the tested materials. The pH variation altered hardness and surface properties of glass ionomer cements but did not influence polyacid-modified resin composites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.Materials and Methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 mu m, 100 mu m, and 200 mu m in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2 x 10(4), 5 x 10(4), and 1 x 10(6) cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two-way ANOVA and Tukey's test (p < 0.05).Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05).Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of a prolonged erosive pH cycling on the superficial microhardness change (SMHC) and the erosive wear of different restorative materials. Eighty enamel specimens with prepared cavities of 1.5 x 1.5 mm were randomly divided into eight groups according to the restorative materials used for the fillings (RMGI - resin-modified glass-ionomer, CGI - conventional glass-ionomer, CR- composite resin, A - amalgam) and immersion media used (ERO - erosive medium or SAL - artificial saliva). During 35 days, half of the specimens were immersed in a cola drink (ERO), for 5 min, three times a day, and they remained in SAL between the erosive cycles. The other half of the specimens was immersed in SAL only, for the entire experimental period (control). Data were tested for significant differences by anova and Tukey's tests (P < 0.05). Scanning electron microscopy images were made to illustrate the enamel erosive wear and restorative materials alterations. The mean SMHC (%) and mean erosive wear (mu m) of the materials were: RMGI-ERO (30/0.5); CGI-ERO (37/0.5); CR-ERO (-0.3/0.3); A-ERO (-4/0.3); RMGI-SAL (4/0.4); CGI-SAL (-6/0.4); CR-SAL (-3/0.2) and A-SAL (2/0.4). Scanning electron microscopy images showed pronounced enamel erosive wear on groups submitted to erosive pH cycling when compared with groups maintained in saliva. In conclusion, the prolonged pH cycling promoted significantly higher alterations (SMHC and erosive wear) on the glass-ionomer cements than the CR and amalgam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of erosive pH cycling on the percentage of surface micro-hardness change (%SMHC) and wear of different restorative materials and bovine enamel restored with these materials. Eighty enamel specimens were randomly divided into eight groups according to the restorative materials and immersion media used: GI/GV-resin-modifled glass-ionomer, GII/GVI-conventional glass-ionomer, GIII/GVII-resin composite and GIV/GVIII-amalgam. Over a period of seven days, groups GI to GIV were immersed in a cola drink (ERO) for 5 minutes, 3x/day and kept in artificial saliva between erosive cycles. Groups GV to GVIII were immersed in artificial saliva (SAL) throughout the entire experimental period (control). Data were tested for significant differences using ANOVA and Tukey's tests (p < 0.05). For %SMHC, considering the restorative materials, no significant differences were detected among the materials and immersion media. Mean wear was higher for the resin modified glass ionomer cement when compared to conventional cement, but those materials did not significantly differ from the others. For enamel analyses, erosive pH cycling promoted higher wear and %SMHC compared to saliva. There were no significant differences in wear and %SMHC of enamel around the different restorative materials, regardless of the distance from the restorative material (50, 150 or 300 mu m). In conclusion, there were only subtle differences among the materials, and these differences were not able to protect the surrounding enamel from erosion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite a plethora of in situ studies and clinical trials evaluating the efficacy of fluoridated dentifrices on caries control, in vitro pH cycling models are still broadly used because they mimic the dynamics of mineral loss and gain involved in caries formation. This paper critically reviews the current literature on existing pH-cycling models for the in vitro evaluation of the efficacy of fluoridated dentifrices for caries control, focusing on their strengths and limitations. A search was undertaken in the MEDLINE electronic journal database using the keywords "pH-cycling", "demineralization", "remineralization", "in vitro", "fluoride", "dentifrice". The primary outcome was the decrease of demineralization or the increase of remineralization as measured by different methods (e. g.: transverse microradiography) or tooth fluoride uptake. Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. One hundred and sixteen studies were included, of which 42 addressed specifically the comparison of dentifrices using different pH-cycling models. The other studies included meta-analysis or reviews, data about the effect of different fluoride sources on de-remineralization, different methods for analysis de-remineralization and chemical variables and characteristics of dental hard tissues that might have influence on de-remineralization processes. Generally, the studies presented ability to detect known results established by clinical trials, to demonstrate dose-related responses in the fluoride content of the dentifrices, and to provide repeatability and reproducibility between tests. In order to accomplish these features satisfactorily, it is mandatory to take into account the type of substrate and baseline artificial lesion, as well as the adequate response variables and statistical approaches to be used. This critical review of literature showed that the currently available pH-cycling models are appropriate to detect dose-response and pH-response of fluoride dentifrices, and to evaluate the impact of new active principles on the effect of fluoridated dentifrices, as well as their association with other anti-caries treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives:Microleakage is a pre-stage of debonding between hard chairside relines and denture base acrylic resins. Therefore, it is important to assess them with regard to the longevity of the relined denture. This study investigated the effect of thermal cycling on the microleakage at the interface of three hard chairside reline resins and three denture base resins.Material and methods:Rectangular bars (12 mm x 3 mm x 3 mm) of Lucitone 550, Acron MC and QC 20 were made and relined with Kooliner, Tokuyama Rebase Fast II and Ufi Gel Hard, Lucitone 550, Acron MC and QC 20 resins. Specimens were divided into one control and two test groups (n = 10). In specimens of the control group, the microleakage was performed after the reline procedure. In Test Group 1, the specimens were stored for 24 h in distilled water at room temperature and in Test Group 2; the specimens were thermal cycled from 5 to 55 degrees C for 5000 cycles with a 30-s dwell time. Subsequently, all specimens were immersed in 50% silver nitrate solutions for 24 h. All specimens were sectioned longitudinally into three fractions and the lateral sections were examined (n = 20). Silver nitrate stain penetration was examined under a stereoscopic lens with x30 magnification, and the images were captured. Leica Qwin image analysis software was used to determine microleakage at the interface of the materials. Data were analysed using the Kruskal-Wallis test at a 95% level of significance.Results:For all cycles, there were no statistically significant differences between thermal cycled and non-thermal cycled groups (p > 0.05).Conclusion:It can be concluded that thermal cycling had no effect on the microleakage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Food restriction (FR) has been shown to promote myocardial dysfunction in rats. The aim of this study was to verify the participation of calcium and beta-adrenergic system on myocardial mechanical alteration in rats submitted to FR. Myocardial performance was studied in isolated left ventricular papillar muscle from young Wistar-Kyoto rats (WKY) submitted to FR or to control diet. The groups subjected to FR were fed 50% less food than the control group for 90 days. Mechanical function was studied in isometric contraction at post-rest contraction of 30 seconds (PRC), calcium chloride concentration 5.20 mM, and beta-adrenergic stimulation with isoproterenol 10(-6) M. FR decreased the body weight, and left and right ventricular weight. In basal condition (1.25 MM of calcium) time to peak tension (TPT) and time from peak tension to 50% relaxation (RT50) were greater in the FR group. Muscle function was. The same in both PRC groups. TPT decrease in both high calcium groups, more in FR rats; RT50 dropped only in FR animals. TPT decreased in both Isoproterenol groups, more intensely in the FR group. This result suggests that food restriction impairs myocardial performance and these changes may be attributed to alterations in the intracellular calcium cycling and beta-adrenergic system. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The maximal lactate steady state (MLSS) is the highest blood lactate concentration that can be identified as maintaining a steady state during a prolonged submaximal constant workload. The objective of the present study was to analyze the influence of the aerobic capacity on the validity of anaerobic threshold (AT) to estimate the exercise intensity at MLSS (MLSS intensity) during cycling. Ten untrained males (UC) and 9 male endurance cyclists (EC) matched for age, weight and height performed one incremental maximal load test to determine AT and two to four 30-min constant submaximal load tests on a mechanically braked cycle ergometer to determine MLSS and MLSS intensity. AT was determined as the intensity corresponding to 3.5 mM blood lactate. MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. MLSS intensity (EC = 282.1 ± 23.8 W; UC = 180.2 ± 24.5 W) and AT (EC = 274.8 ± 24.9 W; UC = 187.2 ± 28.0 W) were significantly higher in trained group. However, there was no significant difference in MLSS between EC (5.0 ± 1.2 mM) and UC (4.9 ± 1.7 mM). The MLSS intensity and AT were not different and significantly correlated in both groups (EC: r = 0.77; UC: r = 0.81). We conclude that MLSS and the validity of AT to estimate MLSS intensity during cycling, analyzed in a cross-sectional design (trained x sedentary), do not depend on the aerobic capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were: (1) to verify the validity of previous proposed models to estimate the lowest exercise duration (T (LOW)) and the highest intensity (I (HIGH)) at which VO(2)max is reached (2) to test the hypothesis that parameters involved in these models, and hence the validity of these models are affected by aerobic training status. Thirteen cyclists (EC), eleven runners (ER) and ten untrained (U) subjects performed several cycle-ergometer exercise tests to fatigue in order to determine and estimate T (LOW) (ET (LOW)) and I (HIGH) (EI (HIGH)). The relationship between the time to achieved VO(2)max and time to exhaustion (T (lim)) was used to estimate ET (LOW). EI (HIGH) was estimated using the critical power model. I (HIGH) was assumed as the highest intensity at which VO2 was equal or higher than the average of VO(2)max values minus one typical error. T (LOW) was considered T (lim) associated with I (HIGH). No differences were found in T (LOW) between ER (170 +/- 31 s) and U (209 +/- 29 s), however, both showed higher values than EC (117 +/- 29 s). I (HIGH) was similar between U (269 +/- 73 W) and ER (319 +/- 50 W), and both were lower than EC (451 +/- 33 W). EI (HIGH) was similar and significantly correlated with I-HIGH only in U (r = 0.87) and ER (r = 0.62). ET (LOW) and T (LOW) were different only for U and not significantly correlated in all groups. These data suggest that the aerobic training status affects the validity of the proposed models for estimating I (HIGH).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of preferred and nonpreferred music on exercise distance, Heart Rate (HR), and Rating of Perceived Exertion (RPE) during continuous cycling exercise performed at high intensity Fifteen participants performed five test sessions During two sessions, they cycled with fixed workload on ergometer to determine the Critical Power (Cl') intensity Then, they performed three more sessions cycling at CP intensity listening to Preferred Music, listening to Nonpreferred Music, and No Music The HR responses in the exercise sessions did not differ among all conditions However, the RPE was higher for Nonpreferred Music than in the other conditions The performance under Preferred Music (9 8 +/- 4 6km) was greater than under Nonpreferred Music (7 1 +/- 3 5km) conditions Therefore, listening to Preferred Music during continuous cycling exercise at high intensity can Increase the exercise distance, and individuals listening to Nonpreferred Music can perceive more discomfort caused by the exercise