39 resultados para Pupil diameter
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Objective To determine the effects of the administration of subconjunctival 1% atropine (SA), topical 1% atropine (A), 0.5% tropicamide (T), 1% homatropine (H), 10% phenylephrine (P), and 2% ibopamine (I) on intraocular pressure (IOP), pupil diameter (PD), ruminal motility (RM) and intestinal motility (IM) in sheep.Animal studied Ten spayed ewes of Santa Ines breed.Procedures Six experiments were performed separately at 1-week intervals. One eye was randomly selected and received one drop of A, T, H, P, I, or subconjunctival injection of atropine at 8 a. m. On the following days, IOP and PD were evaluated every 8 h until the pupil returned to its normal diameter. Ruminal motility and intestinal motility were evaluated only within the first 13 h.Results The IOP did not change significantly in the treated eyes compared with the control eyes and baseline at any time point (P > 0.05). A longer-lasting pupil dilation was observed after the administration of A (96 h), SA (79 h), H (24 h), and T (24 h). Within the first 30 min after treatment, RM and IM decreased, by 78% and 82% (H), 76% and 86% (SA), 46% and 58% (A), and 62% and 70% (T) (P < 0.001), respectively, with a tendency to return to baseline values following 13 h of drug administration. Both 10% phenylephrine and 2% ibopamine did not have any effect on the parameters evaluated (P > 0.05).Conclusions Topical and subconjunctival 1% atropine, 0.5% tropicamide, and 1% homatropine significantly reduced RM and IM, and induced pupil dilation but did not change IOP in eyes of healthy sheep. The sympathomimetics phenylephrine (10%) and ibopamine (2%) did not change the parameters evaluated.
Resumo:
Few quantitative data exist on pupil diameter, particularly in children. In this article we describe an analysis of pupil diameter and pupil area in normal preschool children during attentive gaze (AG) and spontaneous gaze (SG) using digital imaging. The pupil diameter and pupil area of 200 preschool children aged 4 to 6 years were evaluated. The images were recorded with a digital camera, transferred to a computer, processed by movie software and submitted to the Invert filter of Adobe Photoshop (R) software. Three consecutive measures of pupil diameter and pupil area were taken for both eyes during AG and SG. Arithmetic means of each parameter were calculated and data were expressed in millimeters. Mean pupil diameter was similar for both eyes, presenting values of 4.9 mm during AG and 4.1 mm during SG. Mean pupil area was also similar for both eyes, presenting values of 15.6 mm(2) and 9.1 mm(2) during AG and SG, respectively. There were no differences between boys and girls. However, 6-year-old children showed lower pupil diameter and area under both evaluation conditions.
Resumo:
The aim of this study was evaluate the effectiveness of the sodium diclophenac on the mydriasis induced by drugs and on the tearing, blepharospasm and photophobia in normal individuals that received mydriatic or cycloplegic eyedrops. We observed that there was not increase of the pupil diameter with the use of the diclophenac (f = 0,52). The photophobia symptom was mainly present in the patients with dark iris and that received the cycloplegic drops (p < 0,01). The authors concluded that there is not benefit in the use of the sodium dyclophenac eyedrops for the mydriasis increase or the decrease of the ocular symptoms in routine ophthalmologic examination.
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective The aim of the present study was to evaluate the effects of nitrous oxide on TOP and pupillary diameter (PD) of dogs anesthetized with varying desflurane concentrations.Animals studied Twenty adult Mongrel dogs were used.Methods They were anesthetized with propofol (10 mg/kg, IV) and maintained with varying concentrations of desflurane (1.6, 1.4, and 1.2 MAC diluted in 100% oxygen (G1) or in 70% nitrous oxide and 30% oxygen (G2) (30 mL/kg/min). TOP was measured by applanation tonometry and horizontal PD was taken with a caliper adjacent to the cornea. Mean arterial pressure (MAP), heart rate (HR), respiratory rate (RR), and end-tidal CO, (etCO(2)) were also measured. All parameters were measured at TO, T30, T45, and T60 time points. One-way repeated measures ANOVA and the t-test were used to assess statistical differences (P < 0.05).Results T30, T45, and T60 TOP measures were Within normal limits for both groups and TOP did not differ between groups at any time. There was a significant decrease in PD in G I between TO and T30, T45 and T60, and also between T30 and T60. PD did not differ between groups. All vital parameters were within normal limits throughout anesthesia.Conclusions Administration of nitrous oxide with desflurane results in maintenance of normal TOP and prevents a decrease in horizontal PD during anesthesia. Therefore, this may be a suitable protocol in dogs undergoing intraocular surgeries that require mydriasis and maintenance of normal TOP.
Resumo:
O objetivo deste trabalho foi estudar o efeito do diâmetro dos botões florais de algodoeiro na massa corporal de adultos do bicudo-do-algodoeiro, Anthonomus grandis Boheman (Coleoptera: Curculionidae). O experimento foi realizado em condições de campo e laboratório, em Jaboticabal (SP), Brasil. Foram realizadas seis amostragens, coletando-se ao acaso dez plantas nas cultivares Coodetec 405 e Fibermax 986, avaliando-se o número e o diâmetro de botões florais. Os botões florais com orifícios de oviposição foram individualizados em frascos e observados diariamente para a visualização da emergência dos adultos. Botões florais com maiores diâmetros proporcionam maior massa corporal de adultos de A. grandis recém-emergidos nas duas cultivares.
Resumo:
The effect of gibberellic acid has been shown mainly to promote cell division and elongation. This study was aimed to evaluate the development of height and diameter of the stems of chrysanthemum cultivar Yoko ono by the applications of gibberellic acid (GA(3)) in the field. The treatments were composed of four doses (0, 40, 80 and 120 mg L(-1)) at 15 and 30 days after transplanting. From the findings, It can be concluded that GA(3) significantly affected the diameter of stem at higher doses, and was unable to affect the height of stem.
Resumo:
During the construction of five residential buildings in the city of Taubate, State of São Paulo, it was possible to carry out one comprehensive investigation of the behavior of precast concrete piles in clay shales. This paper describes the results of Dynamic Load Tests (DLT's) executed in three piles with different diameters and with the same embedded length. The tests were monitored using the PDA(R) (Pile Driving Analyzer) and the pile top displacement was measured by pencil and paper procedure. From the curves of RMX versus DMX resulted from CASE(R) method, CAPWAPC(R) analyses were made for signals where the maximum mobilized soil resistance was verified. The results were compared with the predicted bearing capacity using the semi-empirical method of Decourt & Quaresma (1978) and Decourt (1982) based on SPT values and the description of the soil profile. Some comments related to the values of quake and damping used for clay shales in the analyses are also presented.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this paper was to develop a model for calculating the economical flow diameter and velocity, by obtaining the economical diameter, using Swamee's friction factor equation, by minimizing the total annual cost. The application of the model to a regular supply condition showed that the diameter of the actual condition, 250 mm, compared with the diameter calculated by the mode, at the same tariff as that applied to the property ( ground), 284.1 mm, involved the necessity to generate, transmit, and distribute extra electrical energy, due to the higher load loss caused by the original diameter, approximately 30800 kWh/year. This means that in one year, the consumer would spend R$2,804.00 more on pumping cost alone.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)