9 resultados para Pulse wave propogation
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.
Resumo:
Introduction: Laser hair removal is becoming an increasingly popular alternative to traditional methods such as shaving, waxing, among other methods. Semiconductor diode lasers are considered the most efficient light sources available and are especially well suited for clinical applications including hair reduction. The effectiveness of laser hair reduction depends on many variables, including the skin type of the patient. Material and Methods: A patient with Fitzpatrick Skin Type IV was submitted to laser hair removal of the arms with a high-power diode laser system with long pulses with a wavelength of 800 nm, a fluence of 40 J/cm2 and a pulse width of 20 ms. A 12-month follow-up assessment was performed and included photography and questionnaire. Results: Hypopigmentation was observed after a single laser hair removal section. After 6 months with the area totally covered, a gradual suntan with a sun screen lotion with an SPF of 15 was prescribed by the dermatologist. After 12 months of the initial treatment, a complete recovery of the hypopigmentation was achieved. Conclusion: Although a safe procedure, lasers for hair removal may be associated with adverse side effects including undesired pigment alterations. Before starting a laser hair removal treatment, patients seeking the eradication of hair should be informed that temporary, and possibly permanent, pigmentary changes may occur. © 2013 Informa UK, Ltd.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
BACKGROUND: Hypertension is the most prevalent comorbidity after heart transplantation (HT). Exercise training (ET) is widely recommended as a key non-pharmacologic intervention for the prevention and management of hypertension, but its effects on ambulatory blood pressure (ABP) and some mechanisms involved in the pathophysiology of hypertension have not been studied in this population. The primary purpose of this study was to investigate the effects of ET on ABP and arterial stiffness of HT recipients.METHODS: 40 HT patients, randomized to ET (n = 31) or a control group (n = 9) underwent a maximal graded exercise test, 24-hour ABP monitoring, and carotid-femoral pulse wave velocity (PWV) assessment before the intervention and at a 12-week follow-up assessment. The ET program was performed thrice-weekly and consisted primarily of endurance exercise (40 minutes) at similar to 70% of maximum oxygen uptake (Vo(2MAX))RESULTS: The ET group had reduced 24-hour (4.0 +/- 1.4 mm Hg, p < 0.01) and daytime (4.8 +/- 1.6 mm Hg, p < 0.01) systolic ABP, and 24-hour (7.0 +/- 1.4 mm Hg, p < 0.001) daytime (7.5 +/- 1.6 mm Hg, p < 0.001) and nighttime (5.9 +/- 1.5 mm Hg, p < 0.001) diastolic ABP after the intervention. The ET group also had improved Vo(2MAX) (9.7% +/- 2.6%, p < 0.001) after the intervention. However, PWV did not change after ET. No variable was changed in the control group after the intervention.CONCLUSIONS: The 12-week ET program was effective for reducing ABP but not PWV in heart transplant recipients. This result suggesfs that endurance ET may be a tool to counteract hypertension in this high-risk population. (C) 2015 International Society for Heart and Lung Transplantation. All rights reserved.
Resumo:
The phenomenon of electrical degradation in ZnO varistors was studied by application of high-intensity current pulses. A wave shape of 8 X 20-mu-s and rectangular waves of 1 and 2 ms were used. The degradation was estimated by reference electric-field variation and by Schottky voltage barrier deformation. The results showed that current pulses reduce both the height and the width of the barrier voltage. It was also observed that the donor density N(d) did not change but the surface states density N(s) decreased with degradation.
Resumo:
We present a solitary solution of the three-wave nonlinear partial differential equation (PDE) model - governing resonant space-time stimulated Brillouin or Raman backscattering - in the presence of a cw pump and dissipative material and Stokes waves. The study is motivated by pulse formation in optical fiber experiments. As a result of the instability any initial bounded Stokes signal is amplified and evolves to a subluminous backscattered Stokes pulse whose shape and velocity are uniquely determined by the damping coefficients and the cw-pump level. This asymptotically stable solitary three-wave structure is an attractor for any initial conditions in a compact support, in contrast to the known superluminous dissipative soliton solution which calls for an unbounded support. The linear asymptotic theory based on the Kolmogorov-Petrovskii-Piskunov assertion allows us to determine analytically the wave-front slope and the subluminous velocity, which are in remarkable agreement with the numerical computation of the nonlinear PDE model when the dynamics attains the asymptotic steady regime. © 1997 The American Physical Society.
Resumo:
In this paper we discuss the propagation of nonlinear electromagnetic short waves in ferromagnetic insulators. We show that such propagation is perpendicular to an externally applied field. In the nonlinear regime we determine various possible propagation patterns: an isolated pulse, a modulated sinusoidal wave, and an asymptotic two-peak wave. The mathematical structure underlying the existence of these solutions is that of the integrable sine-Gordon equation.
Resumo:
In this paper we present the results of a coherent narrow-band search for continuous gravitational-wave signals from the Crab and Vela pulsars conducted on Virgo VSR4 data. In order to take into account a possible small mismatch between the gravitational-wave frequency and two times the star rotation frequency, inferred from measurement of the electromagnetic pulse rate, a range of 0.02 Hz around two times the star rotational frequency has been searched for both the pulsars. No evidence for a signal has been found and 95% confidence level upper limits have been computed assuming both that polarization parameters are completely unknown and that they are known with some uncertainty, as derived from x-ray observations of the pulsar wind torii. For Vela the upper limits are comparable to the spin-down limit, computed assuming that all the observed spin-down is due to the emission of gravitational waves. For Crab the upper limits are about a factor of 2 below the spin-down limit, and represent a significant improvement with respect to past analysis. This is the first time the spin-down limit is significantly overcome in a narrow-band search.