4 resultados para Pull Factors
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Introduction: As opposed to the cementation metal posts, the cementation of fiber posts has several details that can significantly influence the success of post retention. This study evaluated the effect of the relining procedure, the cement type, and the luted length of the post on fiber posts retention. Methods: One hundred eighty bovine incisors were selected to assess post retention; after endodontic treatment, the canals were flared with diamonds burs. Post holes were prepared in lengths of 5, 7.5, and 10 mm; the fiber posts were relined with composite resin and luted with RelyX ARC, RelyX Unicem, or RelyX Luting 2. All cements are manufactured by 3M ESPE (St. Paul, MN). Samples were subjected to a pull-out bond strength test in a universal testing machine; the results (N) were submitted to a three-way analysis of variance and the Tukey post hoc test (alpha = 0.05). Results: The improvement of post retention occurred with the increase of the post length luted into the root canal; the relining procedure improved the pull-out bond strength. RelyX Unicem and RelyX ARC showed similar values of retention, both showing higher values than RelyX Luting 2. Conclusion: Post length, the reining procedure, and the cement type are all important factors for improving the retention of fiber posts. (J Endod 2010;36:1543-1546)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The bond between steel and concrete is essential for the existence of reinforced concrete structures, as both materials act together to absorb structural strain. The bond phenomenon is considered to be complex regarding many factors that affect it. Several types of bond tests have been proposed over years. One is the modified proposed of pull-out test, which was elaborated by Lorrain and Barbosa [1] called APULOT test (Appropriete pull-out-test). Based on experimental results obtained by Vale Silva[2] either by conventional pull-out tests, or by modified pull-out test, APULOT, seeks to know the numeric behavior of bond steel-concrete through a numerical simulation using a calculation code ATENA which is based on the Finite Element Method (FEM). The numerical simulation provided better evaluate the stress distribution and cracking that occurs during the test, thereby becoming a valuable tool to support the experimental project that aims to validation, validation partially or not recommend the modified bond test steel-concrete - APULOT test - as quality control test of structural concrete. The numerical results showed good representation compared to experimental results.