252 resultados para Prova de carga dinamica
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
In Geotechnical engineering the foundation projects depend on the bearing capacity and the acceptable displacements. One of the possible ways to predict the bearing capacity of foundations is through semi-empirical statistical methods which correlate in-situ tests (SPT and CPT). The piles breaking loads are defined by the interpretation of the load x head displacement curve and the experimental data acquired through the load test. In this work it is studied the behavior of bored piles executed in the Araquari/SC region, comparing the bearing capacity values predicted by the methods DECOURT & QUARESMA MODIFICADO (1996), AOKI & VELLOSO MODIFICADO MONTEIRO (2000), MILITITISKY E ALVES (1985), DECOURT & QUARESMA (1978), MÉTODO DE AOKI & VELLOSO (1975) e PHILOPANNAT (1986), with the results of the load test, evaluating their differences and discussing parameters that have direct effects on the prediction
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O objetivo deste estudo foi analisar a validade do consumo máximo de oxigênio (VO2max), velocidade associada ao VO2max (vVO2max), tempo de exaustão na vVO2max (Tlim), limiar anaeróbio (LAn), economia de corrida (EC) e força explosiva (FE) para predizer a performance aeróbia de corredores de endurance nas distâncias de 1.500m, 5.000m e 10.000m. Participaram deste estudo 11 corredores de endurance moderadamente treinados (28,36 ± 6,47 anos) que realizaram os seguintes testes: provas simuladas em uma pista de 400m em diferentes dias, nas distâncias de 10.000m, 5.000m e 1.500m; teste incremental máximo para determinar os índices VO2max, vVO2max, e LAn; um teste submáximo de carga constante para determinar a EC, seguido por um teste máximo também de carga constante a 100% da vVO2max para determinar o Tlim; e um teste de salto vertical para determinar a FE. de acordo com a análise de regressão múltipla, a vVO2max utilizada de forma isolada explicou 57% da variação de performance na prova de 1.500m. No entanto, quando o Tlim, a FE e a vVO2max foram analisados em conjunto, a explicação para a performance nessa prova foi de 88%. Nos 5.000m, o Tlim, a vVO2max e o LAn responderam por 88% da variação de performance (p < 0,05). Diferentemente, na prova de 10.000m, o LAn foi a única variável que apresentou capacidade de predição de performance. em conclusão, a predição da performance aeróbia de corredores moderadamente treinados por meio de variáveis fisiológicas e neuromusculares é dependente da distância da prova (1.500m, 5.000m e 10.000m)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper studies the frame deformations on a formula SAE vehicle in steady-state cornering and its influence on the lateral load transfers and, consequently, on the tires normal loads due to the applied lateral load. For a vehicle with a perfect rigid frame, the vehicle mass, the position of the center of gravity and the suspensions are the only factors responsible for the load distribution between the tires. When the frame deformations are no longer negligible, the frame deformations affect the loaddistribution between the tires. The frame flexibility turns it able to behave as an additional set of springs to the suspension system, thus changing the behavior of the set. This paper describes howit happens and suggests ways to minimize this phenomenon
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the influence of specimen size, in comparison with the ISO Standard, on the three point flexural strength of resin composite restorative materials Filtek Supreme and Filtek Z-250. Forty specimens were fabricated for each material with the following length, width and thickness measurements (n = 10): 1) 20 × 2 × 2 mm (ISO 4049); 2) 10 × 2 × 1 mm; 3) 10 × 1 × 1 mm; 4) 8 × 0.8 × 0.8 mm. The composites were inserted in a single increment into two-piece metal device and light-polymerized. The specimens were dry stored at 37 ± 1 °C and protected from light for 7 days. After this period, flexural strength was measured by three-point flexure test using MTS 810 equipment, with a load cell of 10 kN at a speed of 0.5 mm/min. For the evaluated sizes, the results showed significant variability (p = 0.00) with values when compared with the ISO Standard (116.700 MPa), being statistically higher for the test specimens measuring 10 × 1 × 1 mm (142.530 MPa), similar for those of 10 × 2 × 1 mm (115.815 MPa) and lower for those of 8 × 0.8 × 0.8 mm (86.650 MPa). There was statistical equality (p = 0.08) for the studied composites (Filtek Supreme, 125.270 MPa; Filtek Z-250, 108.130 MPa). Specimens measuring 10 × 2 × 1 mm provided flexural strength values equivalent to those obtained in the sizes recommended by the ISO 4049 standard, with lower consumption of material, energy and time.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)