110 resultados para Programmable logic controller
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Zootecnia - FMVZ
Resumo:
This paper aims to show practical and effectiveexperiencesfor lessons Industrial Automation Laboratory taught inundergraduate degreein ElectricalEngineering from the University Júlio MesquitaFilho - UNESP, Guaratinguetá. Experiments carriedsimulatecontrol and drive systems of electric three phase induction motors (MIT)widely usedinindustries. The experiments simulate a manufacturing environment where there isa need to control the activation and continuous operation ofelectricmotors. Seven experimentsthat simulatethe firing of electrical motors through a controlsystem, a driver along with asimulator loads coupled to the electric motor was developed. Experiments usinga Programmable Logic Controller (PLC) as acontroller,an inverter frequencyasdriver, and MagneticBrake, as simulatorengine loads . The experiments were divided accordingto the speed reference signal used fordrivingand operating the electric motor: digital and analog. The first five experiments performing the drive control and operation of the electric motor via digital signals. The sixth and seventh experiments using an analog signal as a reference speed for the electric motor
Resumo:
This work aims to make the closed loop control of a three phase induction motor, through the integration of the following equipment: a frequency inverter, the actuator system; a programmable logic controller (PLC), the controller; an encoder, the velocity sensor, used as a feedback monitoring the control variable and the three-phase induction motor, the plant to be controlled. The control is performed using a Proportional - Integrative - Derivative (PID) approach. The PLC has a help instruction, which performs the auto adjustment of the controller, that instruction is used and confronted with other adjustment methods. There are several types of methods adjustments to the PID controllers, where the empirical methods are addressed in this work. The system is deployed at the Interface and Electro Electronic Control laboratory in the Universidade Estadual Paulista Júlio Mesquita Filho, Guaratinguetá, São Paulo, then, in the future, this work becomes an experiment to be conducted in the classroom, allowing undergraduate students to develop a greater affinity to the programs used by the PLC as well as studies of undergraduate and graduate works with the help of assembly made
Resumo:
Pós-graduação em Zootecnia - FMVZ
Resumo:
This monograph presents the main objective of analyzing the redundancy protection systems of protection for redundancy and block of energies against accident in presses and rotating equipment. After understanding two specific goals, on this case, show the systems of protection against accidents in rotating equipments, presses and similar; and discuss the vulnerabilities of current systems of protection against accidents in presses and similar, we will propose a system of autonomous redundancy of Programmable Logic Controller (PLC) operating simultaneously taking online in the event of failure of one of the two. The methodology was worked through a revision of a variety of bibliography, and interpretation of national and international standards as well as access to research on systems, practices used in industrial and companies supplying products and of companies and energy blockages solutions
Resumo:
This work presents the development of an IEEE 1451.2 protocol controller based on a low-cost FPGA that is directly connected to the parallel port of a conventional personal computer. In this manner it is possible to implement a Network Capable Application Processor (NCAP) based on a personal computer, without parallel port modifications. This approach allows supporting the ten signal lines of the 10-wire IEEE 1451.2 Transducer Independent Interface (TII), that connects the network processor to the Smart Transducer Interface Module (STIM) also defined in the IEEE 1451.2 standard. The protocol controller is connected to the STIM through the TII's physical interface, enabling the portability of the application at the transducer and network processor level. The protocol controller architecture was fully developed in VHDL language and we have projected a special prototype configured in a general-purpose programmable logic device. We have implemented two versions of the protocol controller, which is based on IEEE 1451 standard, and we have obtained results using simulation and experimental tests. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
The design of full programmable type-2 membership function circuit is presented in this paper. This circuit is used to implement the fuzzifier block of Type-2 Fuzzy Logic Controller chip. In this paper the type-2 fuzzy set was obtained by blurring the width of the type-1 fuzzy set. This circuit allows programming the height and the shape of the membership function. It operates in current mode, with supply voltage of 3.3V. The simulation results of interval type-2 membership function circuit have been done in CMOS 0.35μm technology using Mentor Graphics software. © 2011 IEEE.
Resumo:
This paper presents the control strategies of nonlinear vehicle suspension using a magnetorheological (MR) damper. We used two different approaches for modeling and control of the mechanical and electrical parts of the suspension systems with the MR damper. First, we have formulated and resolved the control problem in order to design the linear feedback dumping force controller for a nonlinear suspension system. Then the values of the control dumping force functions were transformed into electrical control signals by the application of a fuzzy logic control method. The numerical simulations were provided in order to show the effectiveness of this method for the semi-active control of the quarter-car suspension.
Resumo:
A novel hybrid high power rectifier capable to achieve unity power factor is proposed in this paper. Single-phase SEPIC rectifiers are associated in parallel with each leg of three-phase 6-pulse diode rectifier resulting in a programmable input current waveform structure. In this paper it is described the principles of operation of the proposed converter with detailed simulation and experimental results. For a total harmonic distortion of the input line current (THDI) less than 2% the rated power of the SEPIC rectifiers is 33%. Therefore, power rating of the SEPIC parallel converters is a fraction of the output power, on the range of 20% to 33% of the nominal output power, making the proposed solution economically viable for high power installations, with fast pay back of the investment. Moreover, retrofits to existing installations are also possible with this proposed topology, since the parallel path can be easily controlled by integration with the already existing de-link. Experimental results are presented for a 3 kW implemented prototype, in order to verify the developed analysis.
Resumo:
A neural network model for solving constrained nonlinear optimization problems with bounded variables is presented in this paper. More specifically, a modified Hopfield network is developed and its internal parameters are completed using the valid-subspace technique. These parameters guarantee the convergence of the network to the equilibrium points. The network is shown to be completely stable and globally convergent to the solutions of constrained nonlinear optimization problems. A fuzzy logic controller is incorporated in the network to minimize convergence time. Simulation results are presented to validate the proposed approach.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)