12 resultados para Programa de cálculo
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The brachytherapy braquiterapia is an x-ray modality radiotherapy in which stamped or halfstamped radioactive sources in format of seeds are used, wires or to one short distance, in contact or implanted to the fabric to be treated. All the treatment modalities require a previous planning. The formalism recommended for calculation of dose was considered by the AAPM for the first TG-43 Report. In it distributions of dose of isolated seeds measured and calculated by Monte Carlo method in water instead of with models half-empiricists. In this work we in accordance with present some preliminary results of the calculation of functions of radial anisotropy and of dose in the distance for seed of 192Ir, wide used in brachytherapy treatments of high tax of dose (HDR), with the aid of the program based on the Monte Carlo method MCNPX v2.50 (Mount Carlo N ParticleeXtended). The materials chosen in the simulation beyond water, had been MS20 and estriado muscle
Resumo:
This study aimed to develop a computer program which systematizes the structural shielding design calculation in diagnostic radiology facilities. For this purpose methodology of the National Council of Radiation Protection and Measurements (NCRP 147[5]) was used. By comparative statistics studies, it was verified if reference parameters values suggested by the US publication correspond to the average national values. The World Wide Web was chosen because of its characteristics as a powerful mean of communication, especially in terms of the wide variety of useful resources and easy access. To compare the reference values of some parameters proposed by NCRP 147 to Brazilian average, studies about the normalized workload per patient, performance of X-ray tube and primary air kerma, unshielded, at one meter from the focal point of the X-ray tube were made. Through this research, relative differences were found. In workload values this differences reached up to 50% in mammography compared to those presented by the NCRP 147; in X-ray tube performance the percentage differences reached 69% in dental radiology, and air kerma results amounted 31% in fluoroscopy. This demonstrates the importance of validation of international protocols to local realities
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Matemática Universitária - IGCE
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In radiation theraphy with electron beam, the electrons are produced in linear accelerators, and energy the most used have between 4MeV and 20MeV. Generally, the treatments are done for superficial injuries, because the low penetration of these particles. In this work a system for calculation of monitor units (U.M.) for cases of treatments with electron beam was developed. The Excel program of Microsoft was used and is easily found in the operational system of the personal microcomputers. In the Excel has been inserted the pertinent data of the linear accelerator of Varian, model 2100C, used in the Service of radiation theraphy of the Hospital of the Clinics of the College of Medicine of the UNESP of Botucatu. For some values of the physical parameters, such as: factors field and factors calibration, not supplied in the tests of acceptance of the machine, still proceeded calculations from interpolation and extrapolation. The mathematical formulas for automatic search of these and others factors used in the calculations of the determination of the U.M had been developed in agreement available routines in Excel. For this the functions had been used the function IF (that it imposes search condition) and the PROCH (that looks a value in a column from determined line), beyond the basic functions of addition, multiplication and division. It is intended to optimize the routine of the Services of radiation theraphy that perform through eletrontheraphy procedures, speeding the calculations and minimizing the occurrence of errors and uncertainties deriving of the maken a mistake manipulation of the parameters gotten in tables of data of electron beams
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Ciência Animal - FMVA