100 resultados para Programa de Garantia da Atividade Agropecuaria
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Educação - FFC
Resumo:
Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected
Resumo:
The computed tomography, devised by Godfrey Hounsfield and Allan Cormack, is in its fourth decade of the clinical use and has presented to be a very useful tool in the diagnosis of several pathologies. For this reason, its use is increasing each day, due to technological progress since its creation. Due to be more and more utilized, the equipment must be in good operating conditions, because it is subject to variance and wearing, damage the quality of diagnosis. To evaluate whether the performance of the scanner remains constant along the time and the dose received by the patient is within the desired limits, periodic tests of quality control must be performed. For this subject, the regulation 453 (June 01, 1998) was created, which determines the need of the implementation of a program for quality assurance (PGQ), where, in addition to the tests of quality control, are established the necessary measurements for the proper functioning of the equipment, generating a trustworthy diagnosis, reducing the dose for the patient and the costs. In this document, are presented tests of quality control carried out in hospitals of the city of Sao Paulo carried out together with the Technical Section of Applications by Imaging Diagnostic (STADI) of the Institute of Electrotechnics and Energy of the University of São Paulo (IEE/USP)
Resumo:
Radiotherapy is a multidisciplinary speciality which uses complex equipment and radiation sources for delivery of treatment, using high-energy ionizing radiation to treat cancer at several stages of complexity. Since radiation therapy is a technique which involves a precalculated radiation dose, it shall be established quality assurance programs that provide an efficient and safety treatment. The International Commission on Radiation Units and Measurements (ICRU) report No. 50 has recommended dose uniformity between 5% of the prescribed dose throughout the region of interest. This is one of the most primordial points that justify the importance of a suitable attendance of the equipments quality and performance. For quality control, the medical physicist will be involved with establishing and running a Quality Control Program (QCP). He must adapt or develop the procedures of equipment acceptance and commissioning, besides verifying the use of principles and accepted protocols of national and international reports to assure the correct quality, quantity, and placement of radiation during the performance of a radiological procedure, establishing adequate protocols to ensure accurate patient dosimetry. This present work consists of a description of the activities carried through the Sectors of Radiation Therapy of the Hospital of Clinics of the Campinas State University (Unicamp), particularly in the implementation of the Quality Control Program
Resumo:
O uso de radiações ionizantes (R.I.), nas mais variadas atividades tem aumentado nas últimas décadas. Com o avanço tecnológico, novos e sofisticados equipamentos emissores de R.I. tem surgido no cenário nacional, o que torna imperativo a difusão do conhecimento sobre os conceitos de proteção radiológica junto à comunidade em geral, e neste sentido, o curso de física médica desenvolve um importante papel, quer seja no aspecto informativo quanto formativo de cidadãos e profissionais críticos e politicamente corretos, que possam contribuir com as Políticas Públicos dos órgãos normatizadores e fiscalizadores das atividades de vigilância sanitária. Conforme a legislação atual (Resolução SS-625 de 14/12/1994, da Secretaria de Estado da Saúde, e Portaria 453 de 01/06/1998 da Vigilância Sanitária do Ministério da Saúde), todos os serviços que utilizam radiações ionizantes devem realizar testes de avaliação dos parâmetros radiométricos dos equipamentos emissores de R.I., sendo exigidos as medidas de Levantamento Radiométrico das instalações, o Teste de Radiação de Fuga do cabeçote emissor e a implementação de Programa de Garantia de Qualidade dos equipamentos e dos procedimentos radiológicos. Este procedimento tem como objetivo principal a obtenção de imagens radiográficas com qualidade e a segurança de pacientes e profissionais, evitando a exposição desnecessária à radiação de pacientes e profissionais. A correta realização de procedimentos radiológicos além de reduzir a dose nos pacientes também promove significativa diminuição nos custos, por não haver necessidade da repetição dos exames. No Brasil, conforme dados da Secretaria de Atenção à Saúde SAS/MS, atualmente existem instalados 4.469 mamógrafos, 25.930 aparelhos de raios-x médicos, 39.438 aparelhos de raios-x odontológicos e...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to verify the adherence of participants in a program of physical activity; and to verify if there is any association between the age, Body Mass Index and General Functional Fitness Index with this adherence. It was used the control of frequency for 62 months and data of the anthropometric and functional evaluations of 122 participants (58 + 9 years). 49.2% of the participants gave the program up and 50.8% remained to it. The average of permanence time was 24 + 17 months. The percentage of the adherence of people with satisfactory fitness is greater than with not satisfactory fitness. The percentage of adherence of older people is larger than younger age. The percentage of adherence of not-obese is greater than of obese. However, none of these variables presented statistical difference. It can be concluded that even though there was adherence with similar results even to permanence as to desistance, the time of permanence in the program was very high when compared to other studies.
Resumo:
Background: Many studies have shown that physical exercises are able to stimulate bone formation and increase bone mass, constituting a therapeutic modality to treat bone loss due to osteoporosis. However, some points about the intensity, duration and frequency of the exercises remain confusing and contradictory. Thus, the aim of this study was to determine the effects of a progressive loading exercise program on femur of osteopenic rats. To induce osteopenia we used the animal model of ovariectomy (OVX). Forty animals was studied and divided into 4 groups: sham-operated sedentary (SS); ovariectomy-sedentary (OS); sham-operated training (ST) and ovariectomy training (OT). The trained groups performed jumps into water: 4 series of 10 jumps each, with an overload of 50% to 80% of the animal's body weight, during 8 weeks. Femora were submitted to a physical properties evaluation, a biomechanical test, calcium and phosphorus content measurement and a morphometric histological evaluation. Results: osteopenic animals showed a decrease of bone strength and lower values of bone weights, bone density and calcium content. The exercised osteopenic rats showed higher values of geometrical, physical properties, bone strength and calcium content compared to controls. The results of the present study indicate that the progressive loading exercise program had stimulatory effects on femora of osteopenic rats. It seems that the intensity and duration of the protocol used produced bone structural adaptations, which contributed to reverse bone loss due to ovariectomy.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Exergames are a new educational tool, and have been used by teachers in physical education classes because it is an activity that provides entertainment and caloric expenditure. The goal of this study was to verify the opinion of students in an elementary school class on a program of adapted physical activity using the videogame, developed during physical education classes. Study participants were students in a fourth-grade elementary school class that had a student with disability. The researcher and the Physical Education teacher elaborated the planning program of an adapted physical activity with the use of videogames. The classes were recorded in a log book and group interviews were conducted at the end of each class. The results showed that the classes were nice, fun and interesting experiences. The study concluded that the program was successful.
Resumo:
A hipertensão arterial (HA) é fator de risco para o desenvolvimento de doenças cardiovasculares, uma forma de prevenção seria a adoção de um estilo de vida mais ativo.O estudo tem como objetivo verificar se uma sessão de exercícios resistidos e aeróbios provoca efeito hipotensivo em indivíduos normotensos e hipertensos sendo a P.A aferida antes e depois dos exercícios. Participaram do estudo 29 indivíduos, normo e hipertensos, com idade média de 54,96 anos ( ± 9,56 ), todos participantes do projeto de atividade física para diabéticos e hipertensos, desenvolvido pelo NAFES da UNESP – Rio Claro. A aula constituiu-se de aquecimento e alongamento (10 min), parte principal (40 min) dividida por: Caminhada (10 min), exercícios resistidos de membro superior utilizando halteres de um quilo (10 min), caminhada (10 min) e exercícios resistidos de membros inferiores com peso corporal (10 min), finalizando com volta calma(10 min). A Pressão Arterial foi aferida através de aparelho digital de pulso Fuzzy LOGIC, Model 3001, BioLand em repouso(M1), ao termino(M2), 30 minutos pós-exercícios(M3) e 4 horas após o termino dos exercícios(M4). Os dados foram analisados por meio do ANOVA para análises repetidas, através do programa Statistic 7.0 e significância de p<0,05. A analise estatística mostrou que na pressão sistólica não houve diferença significante do M1(137,6 ±17,1mmHg) para o M3(133,9 ±18,8mmHg) enquanto que na pressão diastólica observou-se diferença significativa do M1(84,7 ±9,3mmHg) para o M4(80,7 ±11.2mmHg). Conclusão: Houve efeito hipotensor após exercícios apenas na pressão diastólica, já na pressão sistólica não ocorreu mudança significativa embora todos os valores pós exercícios tenham diminuído, tanot na sistólica quanto na diastólica.