57 resultados para Prensas hidráulicas

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study describes the preliminary design of a static skip compactor and its hydraulic system. The objective of this study is to develop and to improve the design of a made project. The methodology used in this study was to analyze the faults of the already done projects and to suggest possible improvements. The result is a preliminary design of a skip with the main necessary dimensions and specifications to build that equipment. The conclusion of this study is a preliminary project of simple equipment that makes in very efficient way its work

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the field of the projects of hydraulic systems exists a lot of worries when we talk about the calculate of hydraulic pumps. In this case some facts must be considerate: length of tubes, fluid characteristics, height gauge, temperature, pressure, characteristics of tubes, flow required and others. For that mathematic calculates must be developed with the objective to optimize hydraulic pumps and agree to find an ideal machine (that don't requires more energy than necessary or less energy than it requires; that is the more critical case, cause exists the risk that the fluid pumped do not agree to become in your destiny). The wrong calculate of this machine can super-size its, bringing an excessive energy consumption. Actually it's an important subject because we are in the age of lack of energy what turn it more expensive. So the correct sizing of a hydraulic pump is connected with the fact that you have to uses the enough energy resources avoiding waste. The calculate of ideal pump in the pumping system is studied during years and a lot of specialists in this subject develop equations and theories to calculate its. Some researches study about this subject and all of them become to the same conclusion: to find the ideal pump we have to know the characteristics of fluid (cinematic viscosity), the required flow , overall yield (overall of motor x overall of pump) the high gauge or discharge pressure and the loss of repression. The pressure drop can be calculated with different theories: using Hazen-Williams, Darcy e Weisbach or Chézy (1775 - that starts the researches to calculate the pressure drop). Although the most used theory and what is most near to reality is the Darcy's equation. So, in this job the Darcy's equation were choice to calculate the drop pressure that consider what kind of flow we are studying: laminar or turbulent. The determination of the best pump to be used in the ... ( complete abstract click eletronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With growing electricty demand, the importance of generation through hydropower, a renewable energy source, it’s of great importance. This demand derives from the country’s growth, as well as events that will occur in the coming years. The commission has a crucial role before the entry into operation of hydroelectric plant, sice, ensures a good operation of hydraulic and electrical systems, as well as the safety of the installation. This paper is a case study, commissioning in a PCH in especially the most important tests, such as range operation, índex tes and load rejection. In these trials we can get a Idea of the actual behavior of the unit, as well as future operation maneuvers, and evidence of real efficiency

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of this thesis is to describe in details the development and manufacturing of hydraulic fittings for application in truck's cabin tilting lines, covering all of the pre-project, drawing, quotation and supplying processes. This development was planned due to Eaton Corporation - Hydraulics Group's interest in competing on this market with this kind of application. Company's standard procedures were executed until the final supplying stage could be reached. Moreover, the year in which this project was conducted was ruled by a crisis in the automotive segment and new opportunities had to be pursued and developed. Eaton's USA, India and China (facilities located in Aurora, Pune and Shanghai, respectively) engineering team offered all the support in order for this project to come true. As a result there are new part numbers in the company's portfolio, which now offers new fittings and a new type of adapter that was unknown prior to the project. This way Eaton has conquered even more space with this cabin tilting application and the customers (OEMs) have an alternative and homologated supplier to purchase from. Financially speaking, the project's sales income may vary from US$800,000.00 to US$1,300,000.00 worth during the following supplying years

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with a problem of mixed integer optimization model applied to production planning of a real world factory that aims for hydraulic hose production. To optimize production planning, a mathematic model of MILP Mixed Integer Linear Programming, so that, along with the Analytic Hierarchy process method, would be possible to create a hierarchical structure of the most import criteria for production planning, thus finding through a solving software the optimum hose attribution to its respective machine. The hybrid modeling of Analytic Hierarchy Process along with Linear Programming is the focus of this work. The results show that using this method we could unite factory reality and quantitative analysis and had success on improving performance of production planning efficiency regarding product delivery and optimization of the production flow

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This monograph presents the main objective of analyzing the redundancy protection systems of protection for redundancy and block of energies against accident in presses and rotating equipment. After understanding two specific goals, on this case, show the systems of protection against accidents in rotating equipments, presses and similar; and discuss the vulnerabilities of current systems of protection against accidents in presses and similar, we will propose a system of autonomous redundancy of Programmable Logic Controller (PLC) operating simultaneously taking online in the event of failure of one of the two. The methodology was worked through a revision of a variety of bibliography, and interpretation of national and international standards as well as access to research on systems, practices used in industrial and companies supplying products and of companies and energy blockages solutions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A maioria das instalações de abastecimento de água utiliza bombas hidráulicas do tipo turbobombas, requerendo que o interior de sua carcaça e da tubulação de sucção esteja preenchido com água (escorvados) para que a sucção da água possa ser efetivada. O escorvamento das bombas pode ser efetuado instalando-as abaixo do reservatório de captação (bomba afogada). Quando a bomba está acima do reservatório e o escorvamento é manual, é necessário usar válvulas-de-pé, que são suscetíveis ao mau funcionamento, limitando a confiabilidade do sistema, principalmente em caso de automação. Como alternativa à válvula-de-pé, neste trabalho, foram estudados dois tanques escorva, testados no Laboratório de Hidráulica e Irrigação da FCAV/UNESP - Jaboticabal, avaliando-se situações de altura manométrica de sucção de bomba centrífuga e relações entre volume útil do tanque e volume do tubo de sucção, tendo-se concluído: a) o volume do tanque de escorva é função do volume do tubo de sucção da instalação de bombeamento e da altura manométrica de sucção; b) o volume do tanque de escorva pode ser calculado seguindo-se a Lei de Boyle, com percentagem de acréscimo que, neste estudo, foi de 10% para um modelo de tanque e de 30% para o segundo modelo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho teve como objetivo avaliar a distribuição de calda por pontas de pulverização hidráulicas para a aplicação de herbicidas em pré-emergência das plantas daninhas, em função do espaçamento na barra utilizada em áreas de reflorestamento com eucalipto. O experimento foi realizado no Laboratório de Ciência das Plantas Daninhas do Departamento de Fitossanidade da UNESP, Câmpus de Jaboticabal. Foram utilizados os modelos com indução de ar AIUB 025, AI 110025, TTI 110015 e DB 12002, considerando o espaçamento de 0,8; 1,0; 1,2 e 1,5 m entre eles. A avaliação da distribuição da calda pulverizada foi realizada em mesa de deposição. Pulverizou-se água com 0,1% do adjuvante não iônico alquilfenol. Os valores observados foram utilizados para a obtenção das curvas de deposição e do coeficiente de variação. Para a sobreposição de dois exemplares de pontas, conclui-se que o modelo AIUB 025 possui menores coeficientes de variação, resultando em melhores características operacionais em relação à AI 110025, TTI 110015 e DB 12002. Para a utilização de três exemplares de pontas, seguindo somente o critério da distribuição da calda, a melhor combinação foi entre AIUB 025 e DB 12002, como intercalar. A utilização da ponta intercalar aumentou significativamente o consumo de calda.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O efeito de diversas tecnologias de aplicação foi avaliado sobre a concentração, viabilidade e eficácia dos juvenis infectantes dos nematóides Heterorhabditis indica Poinar, Karunakar & David (IBCB-n5) e Steinernema sp. (IBCB-n6) no controle da lagarta-do-cartucho Spodoptera frugiperda Smith na cultura do milho. Para o controle da lagarta-do-cartucho no terceiro estádio em placas de Petri foram necessários 280 juvenis infectantes de Steinernema sp., enquanto que 400 juvenis infectantes de H. indica controlaram apenas 75% das lagartas. Podem-se pulverizar os entomopatógenos, sem que haja perda significativa na sua concentração e viabilidade, com equipamentos que forneçam carga elétrica à calda, ponta centrífuga e pontas hidráulicas. Entretanto, o emprego de pulverizadores com pontas que requerem elementos filtrantes com malha igual a 100 resultou em decréscimo na concentração de juvenis infectantes de H. indica e Steinernema sp., de 28% e 53%, respectivamente. Os tensoativos organosiliconado e etoxilados não afetaram a viabilidade dos juvenis infectantes de Steinernema sp. Nos experimentos de pulverização em plantas de milho (V6) com Steinernema sp., doses equivalentes a até 288 milhões de juvenis infectantes por hectare, diluídos em volume de calda de até 800 L ha-1 com 0,01 % do tensoativo etoxilado, ou nesse volume seguido de exposição a chuva artificial (lâmina de água de 6 mm), não foram suficientes para o controle de S. frugiperda em casa-de-vegetação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A implantação de microcentrais hidrelétricas é uma das alternativas para suprir com energia comunidades pequenas e isoladas, situadas normalmente na área rural. O aproveitamento de potenciais hidráulicos de pequeno porte é uma alternativa cada vez mais viável devido não só à falta de recursos financeiros para os grandes empreendimentos, mas também pelo imenso potencial de geração em centrais de pequeno porte, que pouco tem sido aproveitado. O objetivo deste trabalho foi de apresentar uma metodologia simples de engenharia para estimar o custo das Bombas Funcionando como Turbinas (BFTs) utilizadas em microcentrais hidrelétricas, que possam ser usadas em estudos preliminares de novos aproveitamentos hidrelétricos, sem uma investigação detalhada dos lugares onde se pretende implantar. Os custos foram obtidos consultando-se diretamente os fabricantes de equipamentos e o mercado da praça de Ponta Grossa - PR. Os resultados mostraram que, para as microcentrais hidrelétricas, sempre que os custos constituírem o aspecto dominante, e para potências até 50 kW, a opção por Bombas Funcionando como Turbinas (BFTs) deve ser considerada em lugar das turbinas hidráulicas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)