193 resultados para Prótese Parcial Removível

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Removable partial denture improve functional and aesthetic failures caused by partial loss of teeth, however specific characteristics of each patients can determine the success of treatment, especially with regard to the support of the prosthesis, which may depend on teeth, the combination of teehe and mucosa and currently associated with the dental implants. The aim of this study is report a case in which there was the need of the association, to enable better aesthetics and self-esteem to the patients. After implant placement and fabrication of prosthetic patient reported satisfaction with the rehabilitation treatment, improving their quality of life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Maxillofacial deformities may cause awkward and embarrassing bearer. These patients present serious psychological, family and social issues becoming traumatized and complexed. These deformities can have congenital origin, malformations and developmental disorders, or can be caused by pathological mutilation such as necrotizing diseases and surgical oncology, or traumas such as traffic and work accidents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The literature has suggested that the association of removable partial dentures with dental implants can improve the quality of life of patients. Thus, the purpose of this study was to present a case report. This case report describes the development of a removable partial denture associated with dental implants bilaterally been monitored for 12 years, and the efficacy of the proposed treatment. The radiographic controls demonstrated no changes on bone tissue. The maxillary arch was rehabilitated with metal-free crowns. The patient was fully satisfied with this technique providing stability, esthetics, and proper function. It was concluded that the technique of using removable partial dentures associated with dental implants is viable and show the advantages of improved function, aesthetics and cost reductions in rehabilitation treatment.