Resumo:
The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.
Resumo:
Much has been researched and discussed in the importance played by knowledge in organizations. We are witnessing the establishment of the knowledge economy, but this "new economy" brings in itself a whole complex system of metrics and evaluations, and cannot be dissociated from it. Due to its importance, the initiatives of knowledge management must be continually assessed on their progress in order to verify whether they are moving towards achieving the goals of success. Thus, good measurement practices should include not only how the organization quantifies its knowledge capital, but also how resources are allocated to supply their growth. Thinking about the aspects listed above, this paper presents an approach to a model for Knowledge extraction using an ERP system, suggesting the establishment of a set of indicators for assessing organizational performance. The objective is to evaluate the implementation of projects of knowledge management and thus observe the general development of the organization.
Power performance evaluation of an electric home fan with triac-based automatic speed control system
Resumo:
In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.
Resumo:
The hydrodynamic characterization and the performance evaluation of an aerobic three phase fluidized bed reactor in wastewater fish culture treatment are presented in this report. The objective of this study was to evaluate the organic matter, nitrogen and phosphorous removal efficiency in a physical and biological wastewater treatment system of an intensive Nile Tilapia laboratory production with recirculation. The treatment system comprised of a conventional sedimentation basin operated at a hydraulic detention time HDT of 2.94 h and an aerobic three phase airlift fluidized bed reactor AAFBR operated at an 11.9 min HDT. Granular activated carbon was used as support media with density of 1.64 g/cm(3) and effective size of 0.34 mm in an 80 g/L constant concentration. Mean removal efficiencies of BOD, COD, phosphorous, total ammonia nitrogen and total nitrogen were 47%, 77%, 38%, 27% and 24%, respectively. The evaluated system proved an effective alternative for water reuse in the recirculation system capable of maintaining water quality characteristics within the recommended values for fish farming and met the Brazilian standards for final effluent discharges with exception of phosphorous values. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
New parameterization schemes have been proposed by the authors in Part I of this paper. In this part these new options for the parameterization of power flow equations are tested, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and the transmission line power losses (real and reactive). These different parameterization schemes can be used to obtain the maximum loading point without ill-conditioning problems, once the singularity of Jacobian matrix is avoided. The results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) show that the characteristics of the conventional method are not only preserved but also improved. In addition, it is shown that the proposed method and the conventional one can be switched during the tracing of PV curves to determine, with few iterations, all points of the PV curve. Several tests were also carried out to compare the performance of the proposed parameterization schemes for the continuation power flow method with the use of both the secant and tangent predictors.
Resumo:
This paper presents an improved analysis of a novel Programmable Power-factor-corrected-Based Hybrid Multipulse Power Rectifier (PFC-HMPR) for utility interface of power electronic converters. The proposed hybrid multipulse rectifier is composed of an ordinary three-phase six-pulse diode-bridge rectifier (Graetz bridge) with a parallel connection of single-phase switched converters in each three-phase rectifier leg. In this paper, the authors present a complete discussion about the controlled rectifiers' power contribution and also a complete analysis concerning the total harmonic distortion of current that can be achieved when the proposed converter operates as a conventional 12-pulse rectifier. The mathematical analysis presented in this paper corroborate, with detailed equations, the experimental results of two 6-kW prototypes implemented in a laboratory.
Resumo:
Recently, considerable research work have been conducted towards finding fast and accurate pattern classifiers for training Intrusion Detection Systems (IDSs). This paper proposes using the so called Fuzzy ARTMAT classifier to detect intrusions in computer network. Our investigation shows, through simulations, how efficient such a classifier can be when used as the learning mechanism of a typical IDS. The promising evaluation results in terms of both detection accuracy and training duration indicate that the Fuzzy ARTMAP is indeed viable for this sort of application.
Resumo:
The multi stage filtration (MSF) is an alternative that permits to enlarge the spectrum of application of the slow sand filtration as for the effluent quality and run duration. In this research the use of MSF technology associated to a granular activated carbon (GAC) column as polishing mechanism of the final effluent was evaluated; in the slow sand filters GAC was used as an intermediate layer and non-woven synthetic fabrics were utilized as a first layer of the filter media. Five different tests were conducted, where the systems subjected to the treatment were: water from the Ipe Lake (Ilha Solteira, Sao Paulo, Brazil); water from the lake with water from a recreational fish pond; water from the lake with a phytoplankton and cyanobacteria overload simulation, with and without the use of the pre-filters as a stage of the treatment. The synthetic fabrics and GAC use resulted in the best turbidity removal and an efficient apparent and true color removal; in spite that the polishing columns reported similar results for those parameters. The utilization of GAC as an intermediate layer contributed to a better organic matter removal and the fabrics improved chlorophyll-a removal. The pre-filtration columns made an efficient algae and cyanobacteria removal, a function that was completed by the filters and reached >98% efficiency. The synthetic non-woven fabrics and GAC inclusion in MSF operation improved performance of this technology with ease of application and operation.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This experiment aimed at evaluating the effects of the interactions between aflatoxin (500 or 250 ppb) and ochratoxin (500 or 250 ppb), and the possible benefits of adding yeast cell wall to prevent the effects of these mycotoxins in broiler chickens. Relative organ weight gain and live performance were evaluated at 21 and 42 days of age. Results indicated that at the levels of mycotoxins included in the experimental diets, ochratoxin reduced feed intake and body weight gain, and aflatoxin only affect feed intake of 21-day-old birds. No interaction was observed between aflatoxin and ochratoxin at the levels used in experimental study. Yeast cell wall did not significantly reduced the deleterious effects of ochratoxins. No significant differences were observed in relative organ weight gain. Yeast cell wall improved feed conversion ratio when birds were fed either contaminated or non-contaminated feeds.
Resumo:
Pós-graduação em Educação - FFC
Resumo:
Studies were conducted to evaluate the nutritional value and inclusion levels of babassu meal (BM) in the diet of grower layer pullets in substitution to wheat meal. Digestibility, metabolism and growth trials were conducted. Twelve cecectomized roosters were used in the digestibility assay to determine the coefficients of standardized digestibility of amino acids (CSDAA). The metabolism trial was conducted with 30 adult roosters to determine the apparent metabolizable energy corrected for nitrogen (AMEn) of BM. A growth trial was performed to determine replacement levels of wheat midds by BM diet using 360 six-week-old commercial layer pullets. BM was included at the 0, 75 and 150 g/kg of BM, during grower and development rearing phases, respectively. Feed intake, body weight gain, and feed conversion were evaluated. BM AMEn was determined as 1,474 kcal/kg, on as-fed basis. The CSDAA determined for BM were below 88% for all AA. The inclusion of BM in the feed of grower layers (7-18 week) significantly decreased feed intake (p < 0.05), but significantly improved body weight gain and feedconversion ratio (p < 0.05) at 15% inclusion level. Considering the nutritional value and performance results, BM can replace wheat midds in diets of grower layer pullets.
Resumo:
Most consumers consider the fat of chicken meat undesirable for a healthy diet, due to the high levels of saturated fatty acids and cholesterol. The purpose of this experiment was to investigate the influence of changes in dietary metabolizable energy level, associated with a proportional nutrient density variation, on broiler chickens performance and on the lipid composition of meat. Males and females Cobb 500 broilers were evaluated separately. Performance evaluation followed a completely randomized design with factorial 6x3 arrangement - six energy levels (2,800, 2,900, 3,000, 3,100, 3,200 and 3,300 kcal/kg) and three slaughter ages (42, 49 and 56 days). Response surface methodology was used to establish a mathematical model to explain live weight, feed intake and feed conversion behavior. Total lipids and cholesterol were determined in skinned breast meat and in thigh meat, with and without skin. For lipid composition analysis, a 3x3x2 factorial arrangement in a completely randomized design - three ration’s metabolizable energy levels (2,800, 3,000 and 3,300 kcal/kg), three slaughter ages (42, 49 and 56 days) and two sexes - was used. The reduction in the diet metabolizable energy up to close to 3,000 kcal/kg did not affect live weight but, below this value, the live weight decreased. Feed intake was lower when the dietary energy level was higher. Feed conversion was favored in a direct proportion to the increase of the energy level of the diet. The performance of all birds was within the range considered appropriate for the lineage. Breast meat had less total lipids and cholesterol than thigh meat. Thigh with skin had more than the double of total lipids of skinned thigh, but the cholesterol content did not differ with the removal of the skin, suggesting that cholesterol content is not associated with the subcutaneous fat. Intramuscular fat content was lower in the meat from birds fed diets with lower energy level. These results may help to define the most appropriate nutritional management. Despite the decrease in bird’s productive performance, the restriction of energy in broiler chickens feed may be a viable alternative, if the consumers are willing to pay more for meat with less fat.