3 resultados para Plastic behaviour

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The elastic-plastic structural stability behaviour of arches is analysed in the present work.The application of the developed mathematical model, allows to determine the elastic-plastic equilibrium paths, looking for critical points, bifurcation or limit, along those paths, associated to the critical load, in case it comes to happen.The equilibrium paths in the elastic-plastic behaviour when compared with the paths in the linear elastic behaviour, may show that, due to influence of the material plasticity, modifications paths appear and consequently alterations in the values of its critical loads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an experimental investigation of the characteristics of leak noise in plastic water-filled pipes. An experimental set-up was designed to identify the physical mechanisms of leak noise generation. Possible mechanisms include cavitation and turbulence. The experiments show that cavitation is not responsible for leak noise generation and clearly indicate that turbulence is the main mechanism, at least in the experiments conducted. An alternative experimental set-up was also designed to identify the characteristics of leak noise spectra and to investigate how the spectra are affected by the leak size and the leak flow velocity. A number of different hole sizes (leaks) starting from 1 mm diameter, increasing progressively every 0.5 mm until a size of 4 mm diameter were tested for different jet velocities and an empirical model that describes this behaviour is proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Leakage in buried pipes is one of the main concerns for water companies due to the scarcity of potable water sources. Older metallic pipelines have been replaced by plastic pipes in such systems, which makes it more difficult to locate leaks using acoustics and vibration. This is mainly because of the high attenuation of leak signals caused by the damping in the pipe wall. To investigate acoustic methods in leak location in controlled conditions, a bespoke test rig was constructed in the UK. In this paper, data from this test-rig is used to discuss some issues that arise when using two contemporary correlators. Of particular interest, is the way in which a resonance in the system can have a profound effect on the estimate of the position of the leak depending on the way in which the leak noise signals are processed. © (2013) Trans Tech Publications.