78 resultados para Plantar pressure measurement

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic monitor received the highest degree of BHS recommendations for systolic and diastolic blood pressures according to the BHS. The median (25th and 75th) difference between the observer and the monitor measurements was -2 (-6 and 1) mmHg for systolic and 0 (-3 and1) mmHg for diastolic pressures. The monitor also satisfies the AAMI standard for the studied population. In conclusion, the Omron MX3 Plus monitor can be considered reliable and valid for clinical practice and is in accordance with BHS and AAMI criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies on the distribution of plantar pressure between the sole of the foot and the ground were developed before the 19th century. Currently, the most often employed plantar pressure measurement systems are Pedar® and FScan®, which have restrictions such as operational difficulty and high cost. In the present study, a device was constructed from two pressure plates capable of measuring plantar forces in discreet areas of the feet at a low cost, using strain-gages attached to sixteen strategic points of the mechanical elements. Sixteen prismatic beams were soldered to each frame, for which the free extremity of each beam represented a specific point of the foot. Two strain gauges were attached to each beam - one near the upper fixed extremity and the other near the lower fixed extremity. Using a Wheatstone bridge electric circuit, the gauges were used to measure the force acting on the extremity of the beam. Precision and accuracy of the prototype was about 10%. In some measurements, accuracy was 2%. The low precision and accuracy were mainly due to the restrictions of the available equipment, which only permitted four measurements at a time. Thus, it was necessary for participants to stand on the plates four separate times, which signified possible changes in the position of the feet on the pressure plates. Despite some limitations, the aim was achieved. The prototype has been used in some studies and represents a contribution to biomechanics, demonstrating the viability of using strain gauges.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aims to evaluate and correlate the vascular, sensory and motor components related to the plantar surface in individuals with diabetic peripheral neuropathy. 68 patients were categorized into two groups: 28 in the neuropathic group and 40 in the control group. In each patient, we assessed: circulation and peripheral perfusion of the lower limbs; somatosensory sensitivity; ankle muscle strength; and pressure on the plantar surface in static, dynamic and gait states. We used the Mann-Whitney test and analysis of variance (ANOVA and MANOVA) for comparison between groups, and performed Pearson and Spearman linear correlations amongst the variables (P < 0.05). The somatosensory sensitivity, peripheral circulation and ankle muscle strength were reduced in the neuropathic group. In full peak plantar pressures, no differences were seen between groups, but differences did appear when the foot surface was divided into regions (forefoot, midfoot and hindfoot). In the static condition, the plantar surface area was greater in the neuropathic group. In the dynamic state, peak pressures in the neuropathic group, were higher in the forefoot and lower in the hindfoot, as well as lower in the hindfoot during gait. There were positive or negative correlations between the sensitivity deficit, dorsal ankle flexor strength, plantar surface area, and peak pressure by plantar region. The sensitivity deficit contributed to the increased plantar surface area.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Microalbuminuria may reflect diffuse endothelial damage. Considering that diabetes and hypertension cause vasculopathy, we investigated associations of albumin-to-creatinine ratio (ACR) with plasma glucose and blood pressure levels in high-risk subjects for metabolic syndrome. Methods: A sample of 519 (246 men) Japanese-Brazilians (aged 60 ± 11 years), who participated in a population-based study, had their ACR determined in a morning urine specimen. Backward models of multiple linear regression were created for each gender including log-transformed values of ACR as dependent variable; an interaction term between diabetes and hypertension was included. Results: Macroalbuminuria was found in 18 subjects. ACR mean values for subjects with normal glucose tolerance, impaired fasting glycemia, impaired glucose tolerance and diabetes were 9.9 ± 6.0, 19.0 ± 35.4, 20.7 ± 35.4, and 33.9 ± 55.0 mg/g, respectively. Diabetic subjects showed higher ACR than the others (p < 0.05). An increase in the proportion of albuminuric subjects was observed as glucose metabolism deteriorated (4.9, 17.0, 23.0 and 36.0%). Stratifying into 4 groups according to postchallenge glycemia (< 7.8 mmol/l, n = 9 1; ≥ 7.8 mmol/l, n = 4 10) and hypertension, hypertensive and glucose-intolerant subgroups showed higher ACR values. ACR was associated with gender, waist circumference, blood pressure, plasma glucose and triglyceride (p < 0.05); albuminuric subjects had significantly higher levels of such variables than the normoalbuminuric ones. In the final models of linear regression, systolic blood pressure and 2-hour glycemia were shown to be independent predictors of ACR for both genders (p < 0.05). In men, also waist was independently associated with ACR. No interaction was detected between diabetes and hypertension. Conclusions: These findings suggest that both glucose intolerance and hypertension could have independent but not synergistic effects on endothelial function - reflected by albumin loss in urine. Such hypothesis needs to be confirmed in prospective studies. © 2004 Dustri-Verlag Dr. K. Feistle.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Study design: Association study Objective: To analyze the association between different biological/behavioral risk factors and blood pressure in a sample of type 2 diabetes mellitus patients with poor glycemic control. Methods: A sample of 121 type 2 diabetic patients was selected in the Public Healthcare System in a middle size Brazilian city. Blood pressure was measured using an aneroid device, previously calibrated. Six determinants of blood pressure were taken into count: age, hypoglycemic agents, general obesity, abdominal obesity, eating behaviors and physical activity level. Results: The type 2 diabetic patients presented mean age of 60.1±8.9 years-old and, at least, one risk factor. Eating behaviors (OR adj= 0.31 [0.12-0.75]) and sports practice (OR adj= 0.12 [0.02-0.75]) constituted protective factors associated with lower systolic blood pressure. On the other hand, age was positively associated with high systolic blood pressure (OR adj= 3.81 [1.39-10.38]). Patients with 5-6 risk factors, presented higher values of systolic and (F= 3.857; p= 0.011 [post hoc with p= 0.039]), diastolic blood pressure (F= 4.158; p= 0.008 [post hoc with p= 0.036]) and increased occurrence of hypertension (p= 0.010). Conclusion: Our findings indicate that, behavioral variables were important determinants of blood pressure in type 2 diabetic patients with poor glycemic control and clustering of behavioral and biological risk factors increase the hypertension occurrence.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: To examine the independent and combined association of physical activity (PA) and sedentary behavior (SB) on both systolic (SBP) and diastolic blood pressure (DBP) in adolescents from two observational studies. Methods: Participants from two cross-sectional studies, one conducted in Europe (n = 3,308; HELENA study) and the other in Brazil (n = 991; BRACAH study), were selected by complex sampling. Systolic and diastolic blood pressure (outcomes), PA and SB, both independently and combined, and potential confounders were analyzed. Associations were examined by multilevel linear regression. Results: Performing the recommended amount of PA (≥60 min/d) attenuated the effect of SB on DBP in BRACAH study girls and in boys from both studies. In contrast, PA did not attenuate the effects of SB on the SBP of girls in the HELENA study. The combination of less than recommended levels of PA with 2-4 h/d of sedentary behavior was found to be associated with increased SBP in boys from both studies. Conclusions: Meeting current PA recommendations could mediate the association between SB and DBP in both sexes. In boys, the joint effect of low levels of PA and excessive sedentary activity increases SBP levels. Longitudinal studies are required to confirm these findings. © 2013 de Moraes et al.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO:Revisar a literatura sobre estudos que estimaram a prevalência de pressão arterial elevada (PAE) ou hipertensão arterial sistêmica (HAS) em adolescentes brasileiros, considerando os procedimentos metodológicos empregados.MÉTODOS:Pesquisa bibliográfica de estudos de prevalência de PAE/HAS em adolescentes de 1995 a 2010. A busca foi realizada nas bases de dados eletrônicos PubMed/Medline, Lilacs, SciELO, Isi e Adolec. Foram utilizados os descritores: hipertensão, pressão arterial, adolescente, estudantes, estudos transversais, prevalência e Brasil, nas línguas portuguesa e inglesa. Além disso, foi elaborado um escore, baseado nas Recommendations for Blood Pressure Measurement in Humans and Experimental Animals e nas VI Diretrizes Brasileiras de Hipertensão, para a análise dos procedimentos utilizados para medida da PA nos estudos variando de 0 a 18.RESULTADOS:Foram identificados 21 artigos, a maioria publicada nos últimos 10 anos, sendo 90,5% realizados em base escolar e nas regiões sudeste, nordeste e sul do país. As prevalências de PAE/HAS variaram de 2,5 a 30,9%. A pontuação dos estudos variou de 0 a 16. Foi observada uma correlação negativa significante (rho = -0,504; p = 0,020) entre a prevalência de PAE/HAS e o escore da qualidade da medida da PA.CONCLUSÃO:A grande variabilidade das estimativas da PAE/HAS parece ser influenciada pelos procedimentos metodológicos utilizados nos estudos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

FUNDAMENTO: A medida precisa da pressão arterial é fundamental para a investigação científica ou decisão clínica. Nesse sentido, é importante verificar valores fornecidos por equipamentos eletrônicos. OBJETIVO: Validar o monitor Omron HEM 742 de medida de pressão arterial em adolescentes, segundo os critérios sugeridos pela British Hypertension Society. MÉTODOS: Participaram do estudo 150 adolescentes com idades entre 10 e 16 anos. O monitor automático Omron HEM 742 foi conectado em Y com equipamento auscultatório de coluna de mercúrio, e realizaram-se três avaliações simultâneas, calculando-se as diferenças entre os dois equipamentos. Para verificar a relação entre ambos, utilizaram-se o coeficiente de correlação intraclasse e a plotagem de Bland-Altman (concordância). A especificidade e a sensibilidade do aparelho foram determinadas pela curva ROC. RESULTADOS: A comparação entre as medidas acusou uma diferença menor ou igual a 5 mmHg em 67,3% dos valores sistólicos e 69,3% dos valores diastólicos; uma diferença menor ou igual a 10 mmHg ocorreu em 87,3% e 90,6% dos valores sistólicos e diastólicos, respectivamente; e uma diferença menor ou igual a 15 mmHg em 96,6% dos valores sistólicos e 97,3% dos diastólicos. Esses resultados indicam grau A segundo o protocolo da British Hypertension Society. Observou-se ainda elevada concordância nos valores obtidos por meio do monitor automático, e verificou-se que esse equipamento é capaz de identificar a presença ou a ausência da pressão arterial elevada. CONCLUSÃO: O monitor Omron HEM 742 mostrou-se válido para medidas de pressão arterial em adolescentes, conforme os critérios sugeridos pela British Hypertension Society.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O Diabetes mellitus é uma enfermidade crônica que leva a alterações sensitivas e motoras. Tais alterações comprometem o equilíbrio e a deambulação, predispondo seus portadores à ocorrência de quedas. Esta revisão teve por objetivo levantar, na literatura recente, estudos que visassem avaliar parâmetros da marcha e aspectos envolvidos com a deambulação. Para isso, foi realizada uma busca nas bases de dados MEDLINE, SciELO, LILACS e PEDro, cruzando as palavras-chave: Neuropatias Diabéticas x Marcha; Diabetes Mellitus x Marcha e Pé Diabético x Marcha. Após passarem pelos critérios de seleção, foram obtidos 15 artigos, os quais foram sintetizados e discutidos, sendo, portanto, incluídos nesta revisão. Ficou claro que a neuropatia diabética leva a déficits na amplitude do passo, velocidade e cadência da marcha em superfícies planas, sem mudanças bruscas de direção ou paradas, e déficits de equilíbrio e coordenação em aclives, declives e terrenos irregulares. Acarreta, também, aumento dos índices de pressão plantar e, devido à alteração de ativação do tríceps sural, dificuldade na fase de apoio terminal e pré-balanço. Assim, o próximo contato inicial ocorrerá de maneira inadequada, com o antepé e sem absorção de choques.