Running exercises are frequently related to muscular injuries, which may be a result of muscular imbalance. The present study aimed to verify the effects of heavy-intensity continuous running exercise on the functional and conventional hamstrings: quadriceps ratios, and also in the knee flexors and extensors EMG activity in active non-athletic individuals. Sixteen active males performed maximal isokinetic concentric and eccentric knee flexions and extensions at 60 degrees s(-1) and 180 degrees s(-1). In another session, the same procedure was conducted after a continuous running exercise at 95% onset of blood lactate accumulation. Torque and electromyographic ratios were calculated from peak torque and integrated electromyographic activity (knee flexor and extensors). Creatine kinase was measured before and 24 h after running exercise. Eccentric torque (knee flexion and extension) decreased significantly after running only at 180 degrees s(-1) (p < 0.05). No differences were found for the conventional torque ratios (p > 0.05), however, the functional torque ratios at 180 degrees s(-1) decreased significantly after running (p < 0.05). No effects on the electromyographic activity and electronnyographic ratios were found (p > 0.05). Creatine kinase increased slightly 24 h after running (p < 0.05). Heavy-intensity continuous running exercise decreased knee flexor and extensor eccentric torque, and functional torque ratios under fast velocities (180 degrees s(-1)), probably as result of peripheral fatigue. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The effects of age on microbiota composition, gut fermentation end-product formation and peripheral lymphocyte numbers were compared between old and young adult Beagle dogs fed four kibble diets differing in yeast cell wall contents. The experiment had a double 4 x 4 Latin square design, one with four mature dogs (4 years old) and the other with four old dogs (10 years old), with four replicates (diets) per dog. In each period a 15d adaptation period preceded a 5d total collection of faeces for the digestibility trial. on day 21, fresh faecal samples were collected for the determination of bacterial enumeration, pH, biogenic amine and short-chain fatty acid. Flow cytometry was used for immunophenotypic evaluation. Dogs were fed four kibble diets with similar composition with 0, 0.15, 0.30 and 0.45% of yeast cell wall (as-fed), respectively. Data were evaluated using general linear models of Statistical Analysis Systems statistical software (P<0.05). No evidence of a difference in faecal bacteria counts between ages was found (total aerobes, total anaerobes, Bifidobacterium, Lactobacillus, Clostridium and Escherichia coli: P. 0.15). Faecal concentrations of butyrate, histamine, agmatine and spermine were lower (P <= 0.05) and faecal pH was higher (P=0.03) in older dogs than in mature adult dogs, suggesting an alteration in bacterial metabolic activity, or in the rate of intestinal absorption of these compounds. Concentrations of T-lymphocytes, T-cytotoxic lymphocytes and B-lymphocytes were also lower (P <= 0.01) in older dogs than in mature adult dogs. The study confirmed alterations in peripheral lymphocytes and revealed a reduced concentration of some fermentation end products in the colon of old dogs.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A Neuropatia diabética periférica (NDP) cursa com redução somatossensitiva que pode levar a alterações no controle postural. O objetivo do estudo foi avaliar o controle postural na postura ereta, em diferentes condições, e o equilíbrio funcional em indivíduos com NDP, correlacionar os resultados obtidos na avaliação do controle postural com os valores do teste do equilíbrio funcional e comparar os resultados obtidos no grupo neuropata com o grupo controle, verificando as possíveis diferenças entre as condições de avaliação em ambos os grupos. Participaram do estudo 13 mulheres com NDP (GN) e 17 mulheres não diabéticas (GC). A avaliação do controle postural foi realizada por cinemetria nas condições: olhos abertos (OA), olhos fechados (OF) e semi tandem (ST). Após processamento no MATLAB, foram geradas as variáveis: amplitude média de oscilação (AMO) na direção ântero-posterior (AP) e médio-lateral (ML); e velocidade média de oscilação (VMO) na direção AP e ML. O equilíbrio funcional foi avaliado pelo Timed Up and Go Test. Houve diferença significante entre os grupos (p<0,005) na AMO-AP OA e OF, AMO-ML of e ST e VMO-ML ST. Houve diferença entre as condições OA e ST (p<0,005) e of e ST (p<0,005) para as variáveis AMO-ML e VMO-ML, com maior prejuízo para o GN, que também apresentou um menor equilíbrio funcional (p=0,001). A instabilidade ML foi correlacionada positivamente com o desequilíbrio funcional. Os resultados nos mostram uma alteração no sistema de controle postural na NDP, o que pode levar estes indivíduos a um maior risco a quedas e prejuízos funcionais.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Chromium electrodeposition is a technique for the production of functional coatings on engineering components. These coatings are extensively micro-cracked and present high level of hardness, resistance to corrosion and wear and low coefficient of friction. In this paper the shot peening influence on the fatigue strength of aluminum 7050-T7451 alloy chromium electroplated, was investigated.The shot peening process was carried out to create residual stresses using ceramic and glass shots. A hard chromium electroplated coating of 100 mu m thickness was performed on the base material and the shot peened base material surfaces. S-N curves were obtained in axial and bending fatigue tests and compared with the 7050-T7451 aluminum alloy. In order to study the influence of residual stresses on fatigue life, the behavior of compressive residual stress field was measured by an X-ray tensometry.An increase in the axial fatigue strength of 25% and 50% of ceramic and glass shots, respectively, was observed. The lower performance in fatigue life for ceramic-shot peening may be attributed to higher surface damage, as a consequence of the overpeening intensity performed. However, in bending fatigue the behavior was practically equivalent for both processes. Fracture surface analysis by scanning electron microscopy was used to observe crack origin sites from shot peened and chromium electroplated samples. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
In recent years, with higher demand for improved quality and corrosion resistance, recovered substrates have been extensively used. Consequently residual stresses originated from these coatings reduce the fatigue strength of a component. Due to this negative influence occasioned by corrosion resistance protective coatings, an effective process like shot peening must be considered to improve the fatigue strength. The shot peening treatment pushes the crack sources beneath the surface in most of medium and high cycle cases due to the compressive residual stress field (CRSF) induced. The aim of this study was to evaluate the influence on the fatigue life of anodic films grown on 7050-T7451 aluminium alloy by sulphuric acid anodizing, chromic acid anodizing and hard anodizing. The influence on the rotating and reverse bending fatigue strength of anodic films grown on the aluminium alloy is to degrade the stress life fatigue performance of the base material.A consistent gain in fatigue life in relation to the base material was obtained through the shot peening process in coated specimens, associated to a residual stress field compressive near the surface, useful to avoid fatigue crack nucleation and delay or even stop crack propagation.
Resumo:
Deposition of wear-resistant hard chromium plating leads to a decrease in the fatigue strength of the base material. Despite the effective protection against wear and corrosion, fatigue life and environmental requirements result in pressure to identify alternatives or to improve conventional chromium electroplating mechanical characteristics. An interesting, environmentally safer and cleaner alternative for the replacement of hard chronic plating is tungsten carbide thermal spray coating, applied by high velocity oxyfuel (HVOF) process.To improve the fatigue strength of aeronautical steel chromium electroplated, shot peening is a successfully used method. Multiple lacer systems of coatings are considered to have larger resistance to crack propagation in comparison with simple layer.The aim of this study was to analyze the effect of nickel underplate on the fatigue strength of hard chromium plated AISI 4340 steel in two mechanical conditions: HRc 39 and HRc 52.Rotating bending fatigue tests results indicate that the clectroless nickel plating underlayer is responsible for the increase in fatigue strength of AISI 4340 steel chromium electroplated. This behavior may be attributed to the largest toughness/ductility and compressive residual stresses which, probably, arrested or delayed the inicrocrack propagation from the hard chromium external layer. The compressive residual stress field (CRSF) induced by the electroplating process was determined by X-ray diffraction method. The evolution of fatigue strength compressive residual stress field CRSF and crack sources are discussed and analyzed by SEM. (c) 2006 Elsevier Ltd. All rights reserved.