17 resultados para Performance Measures
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Recent studies have shown that adaptive X control charts are quicker than traditional X charts in detecting small to moderate shifts in a process. In this article, we propose a joint statistical design of adaptive X and R charts having all design parameters varying adaptively. The process is subjected to two independent assignable causes. One cause changes the process mean and the other changes the process variance. However, the occurrence of one kind of assignable cause does not preclude the occurrence of the other. It is assumed that the quality characteristic is normally distributed and the time that the process remains in control has exponential distribution. Performance measures of these adaptive control charts are obtained through a Markov chain approach. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this study, we estimated the heritability (h(2)) of earnings in the Quarter Horse in order to evaluate the inclusion of this trait in breeding programs. Records from 14,754 races of 2443 horses from 1978-2009 were provided by Sorocaba Hippodrome, Sao Paulo, Brazil. All ancestors of the registered horses were included in the pedigree file until the 4th generation. Log-transformed performance measures (LPM) were analyzed for animals aged 2, 3, and 4 years and during their entire career. The h(2) estimates were obtained using a multi-trait model and Gibbs sampling that included the effects of sex, year of race, and animal in all analyses. Five analyses were performed: 1 in which LPM was divided by the number of prizes, 1 in which LPM was divided by the number of race starts, and 3 analyses that included the number of prizes, number of race starts, and both (LPM_cNPS) as covariates. Analysis was performed with and without inclusion of the maternal effect. Models were compared based on the deviance information criterion and LPM_cNPS including maternal effects was found to be the best model. The h(2) estimates and standard deviation obtained using model LPM_cNPS were 0.19 +/- 0.08, 0.21 +/- 0.08, 0.22 +/- 0.09, and 0.21 +/- 0.07 for earnings at 2, 3, and 4 years of age and total career, respectively. Our analyses indicate that earnings are subject to selection and can be included in breeding programs to improve the racing performance of Quarter Horses.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Psicologia do Desenvolvimento e Aprendizagem - FC
Resumo:
Poor posture control has been associated with an increased risk of falls and mobility disability among older adults. This study was conducted to assess the test-retest reliability and sensitivity to group differences regarding the time-limit (TLimit) of one-leg standing and selected balance parameters obtained with a force platform in older and young adults. A secondary purpose was to assess the relationship between TLimit and these balance parameters. Twenty-eight healthy older adults (age: 69±5years) and thirty young adults (age: 21±4years) participated in this study. Two one-leg stance tasks were performed: (1) three trials of 30s maximum and (2) one TLimit trial. The following balance parameters were computed: center of pressure area, RMS sway amplitude, and mean velocity and mean frequency in both the anterio-posterior and medio-lateral directions. All balance parameters obtained with the force platform as well as the TLimit variable were sensitive to differences in balance performance between older and young adults. The test-retest reliability of these measures was found to be acceptable (ICC: 0.40-0.85), with better ICC scores observed for mean velocity and mean frequency in the older group. Pearson correlations coefficients (r) between balance parameters and TLimit ranged from -0.16 to -0.54. These results add to the current literature that can be used in the development of measurement tools for evaluating balance in older and young adults. © 2013 Elsevier Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Evaluation of rhythmic fluctuations cf physical and mental variables should be of special significance for the understanding of students' performance and setting the schedules of school activities. The present study investigated the pattern of diurnal variation in oral temperature, sleepiness and performance of a group of adolescents undergoing a daytime school schedule. Eighteen girls (mean age 16 years-old), who attended the same class from 0715h to 1645h, were tested on seven days. They measured their oral temperature, quantified their sleepiness level by means of a visual analogue scale, and completed the following tests: letter cancellation test, addition test, and a simple motor task. One-way ANOVA statistics for repeated measures was used in order to verify the effect of test time on oral temperature,sleepiness and performance. Possible correlations between the level of sleepiness and performance were investigated by means of Spearman rank correlation. The results revealed significant time of day effect cn all variables, except for the number of addition errors. Oral temperature values showed an increase from morning to afternoon. Letter cancellation, motor task and addition scores increased from early morning to late afternoon, showing rapid fluctuations throughout the day. Sleepiness level was negatively correlated with letter cancellation scores during the first three tests of the day. In agreement with other work, the diurnal variation of oral temperature, letter cancellation and addition test showed an improvement as the day progressed. Sleepiness, on the other hand, decreased throughout the day, with the highest level associated with the first test of the day, suggesting a circadian pattern of variation rather than a cumulative effect due to school activities.
Resumo:
Processing efficiency theory predicts that anxiety reduces the processing capacity of working memory and has detrimental effects on performance. When tasks place little demand on working memory, the negative effects of anxiety can be avoided by increasing effort. Although performance efficiency decreases, there is no change in performance effectiveness. When tasks impose a heavy demand on working memory, however, anxiety leads to decrements in efficiency and effectiveness. These presumptions were tested using a modified table tennis task that placed low (LWM) and high (HWM) demands on working memory. Cognitive anxiety was manipulated through a competitive ranking structure and prize money. Participants' accuracy in hitting concentric circle targets in predetermined sequences was taken as a measure of performance effectiveness, while probe reaction time (PRT), perceived mental effort (RSME), visual search data, and arm kinematics were recorded as measures of efficiency. Anxiety had a negative effect on performance effectiveness in both LWM and HWM tasks. There was an increase in frequency of gaze and in PRT and RSME values in both tasks under high vs. low anxiety conditions, implying decrements in performance efficiency. However, participants spent more time tracking the ball in the HWM task and employed a shorter tau margin when anxious. Although anxiety impaired performance effectiveness and efficiency, decrements in efficiency were more pronounced in the HWM task than in the LWM task, providing support for processing efficiency theory.
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to 'detect occlusal caries.Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site.Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy far the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly.Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the Sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure.Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
Purpose: This study evaluated the impact of socioeconomic factors on children's performance on tests of working memory and vocabulary.Method: Twenty Brazilian children, aged 6 and 7 years, from low-income families, completed tests of working memory ( verbal short-term memory and verbal complex span) and vocabulary ( expressive and receptive). A further group of Brazilian children from families of higher socioeconomic status matched for age, gender, and nonverbal ability also participated in the study.Results: Children from the low socioeconomic group obtained significantly lower scores on measures of expressive and receptive vocabulary than their higher income peers but no significant group differences were found on the working memory measures.Conclusion: Measures of working memory provide assessments of cognitive abilities that appear to be impervious to substantial differences in socioeconomic background. As these measures are highly sensitive to language ability and learning in general, they appear to provide useful methods for diagnosing specific learning difficulties that are independent of environmental opportunity.
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.