23 resultados para PSD

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method of determining spectral parameters p (slope of the phase PSD) and T (phase PSD at 1 Hz) and hence tracking error variance in a GPS receiver PLL from just amplitude and phase scintillation indices and an estimated value of the Fresnel frequency has been previously presented. Here this method is validated using 50 Hz GPS phase and amplitude data from high latitude receivers in northern Norway and Svalbard. This has been done both using (1) a Fresnel frequency estimated using the amplitude PSD (in order to check the accuracy of the method) and (2) a constant assumed value of Fresnel frequency for the data set, convenient for the situation when contemporaneous phase PSDs are not available. Both of the spectral parameters (p, T) calculated using this method are in quite good agreement with those obtained by direct measurements of the phase spectrum as are tracking jitter variances determined for GPS receiver PLLs using these values. For the Svalbard data set, a significant difference in the scintillation level observed on the paths from different satellites received simultaneously was noted. Then, it is shown that the accuracy of relative GPS positioning can be improved by use of the tracking jitter variance in weighting the measurements from each satellite used in the positioning estimation. This has significant advantages for scintillation mitigation, particularly since the method can be accomplished utilizing only time domain measurements thus obviating the need for the phase PSDs in order to extract the spectral parameters required for tracking jitter determination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radial profiles are reported of average and rms temperature in a propane flame for the first, second, and third acoustic modes at four different axial positions above the burner in a Rijke-tube combustor. Selected plots of the power spectral density (PSD) of temperature fluctuations are also reported. These radial profiles are then compared to similar ones made in the same flame, but in the absence of the acoustic field. Visual observations and photographs of the flame showed a remarkable change in flame height and structure with the onset of acoustic oscillations. This reduction in flame length, caused by the enhanced mixing due to the acoustic velocity fluctuations, gave rise to higher and lower average and rms temperatures near or well above the burner, respectively. In general, the PSD plots had a broad frequency content. The general trend was a decrease in magnitude with an increase in frequency. All cases presented broad-band peaks at around 5 Hz related to the flame flickering phenomenon. Preferred frequencies were observed in the oscillating PSD plots related to the fundamental frequency as well as subharmonics in the tube. (C) 2000 Elsevier B.V. Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an experimental technique for structural health monitoring (SHM) based on Lamb waves approach in an aluminum plate using piezoelectric material as actuators and sensors. Lamb waves are a form of elastic perturbation that remains guided between two parallel free surfaces, such as the upper and lower surfaces of a plate, beam or shelf. Lamb waves are formed when the actuator excites the surface of the structure with a pulse after receiving a signal. Two PZTs were placed in the plate surface and one of them was used to send a predefined wave through the structure. Thus, the other PZT (adjacent) becomes the sensor. Using this methodology, this paper presents one case of damage detection considering the aluminum plate in the free-free-free-free boundary condition. The damage was simulated by adding additional mass on the plate. It is proposed two damage detection indexes obtained from the experimental signal, involving the Fast Fourier Transform (FFT) and the power spectral density (PSD) that were computed using the output signal. The results show the viability of the presented methodology to damage detection in smart structures

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The social wasp P. paulista is relatively common in southeast Brazil causing many medically important stinging incidents. The seriousness of these incidents is dependent on the amount of venom inoculated by the wasps into the victims, and the characteristic envenomation symptoms are strongly dependent on the types of peptides present in the venom. In order to identify some of these naturally occurring peptides available in very low amounts, an analytical protocol was developed that uses a combination of reversed-phase and normal-phase high-performance liquid chromatography (HPLC) of wasp venom for peptide purification, with matrix-assisted laser desorption/ionization time-of-flight post-source decay mass spectrometry (MALDI-Tof-PSD-MS) and low-energy collision-induced dissociation (CID) in a quadrupole time-of-flight tandem mass spectrometry (QTof-MS/MS) instrument for peptide sequencing at the sub-picomole level. The distinction between Leu and Ile was achieved both by observing d-type fragment ions obtained under CID conditions and by comparison of retention times of the natural peptides and their synthetic counterparts (with different combinations of I and/or L at N- and C-terminal positions). To distinguish the isobaric residues K and Q, acetylation of peptides was followed by Q-Tof-MS analysis. The primary sequences obtained were INWLKLGKMVIDAL-NH2 (MW 1611.98Da) and IDWLKLGKMVMDVL-NH2 (MW 1658.98Da). Micro-scale bioassay protocols characterized both peptides as presenting potent hemolytic action, mast cell degranulation, and chemotaxis of poly-morphonucleated leukocyte (PMNL) cells. The primary sequences and the bioassay results suggest that these toxins constitute members of a new sub-class of mastoparan toxins, directly involved in the occurrence of inflammatory processes after wasp stinging. Copyright (C) 2004 John Wiley Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have examined the applicability of the 'nested' collision induced dissociation/post-source decay (CID/PSD) method to the sequencing of novel peptides from solitary wasps which have neurotoxic venom for paralyzing other insects. The CID/PSD spectrum of a ladder peptide derived from an exopeptidase digest was compared with that of the intact peptide. The mass peaks observed only in the CID/PSD spectrum of a ladder peptide were extracted as C-terminal fragment ions. Assignment of C-terminal fragment ions enabled calculation of N-terminal fragment masses, leading to differentiation between N-terminal fragment ions and internal fragment ions. This methodology allowed rapid and sensitive identification by removing ambiguity in the assignment of the fragment ions, and proved useful for sequencing unknown peptides, in particular those available as natural products with a limited supply. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The protein complement of the secretion from hypopharyngeal gland of nurse-bees (Apis mellifera L.) was partially identified by using a combination of 2D-PAGE, peptide sequencing by MALDI-PSD/MS and a protein engine identification tool applied to the honeybee genome. The proteins identified were compared to those proteins already identified in the proteome complement of the royal jelly of the honey bees. The 2D gel electrophoresis demonstrated this protein complement is constituted of 61 different polypepides, from which 34 were identified as follows: 27 proteins belonged to MRJPs family, 5 proteins were related to the metabolism of carbohydrates and to the oxido-reduction metabolism of energetic Substrates, I protein was related to the accumulation of iron in honeybee bodies and I protein may be a regulator of MRJP-1 oligomerization. The proteins directly involved with the carbohydrates and energetic metabolisms were: alpha glucosidase, glucose oxidase and alpha amylase, whose are members of the same family of enzymes, catalyzing the hydrolysis of the glucosidic linkages of starch; alcohol dehydrogenase and aldehyde dehydrogenase, whose are constituents of the energetic metabolism. The results of the present manuscript support the hypothesis that the most of these proteins are produced in the hypoharyngeal gland of nurse-bees and secreted into the RJ. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo foi comparar a magnitude do efeito protetor (EP) contra o dano muscular (DM) induzido por uma sessão de exercícios excêntricos (EEM) entre os extensores do joelho e os flexores do cotovelo. Doze sujeitos do gênero masculino foram divididos em 2 grupos, braços (GB) e pernas (GP), e realizaram 2 sessões de EEM. Foram coletados 3 marcadores de DM, sendo eles, pico de torque isométrico (PTI), creatina quinase (CK) e percepção subjetiva de dor (PSD), antes, imediatamente após (com exceção da CK) e 48 horas após cada sessão de EEM. Foi encontrada queda significante de PTI e aumento significante de CK e PSD tanto imediatamente e 48 horas após a primeira sessão de EEM para o GB. No GP houve aumento significante de CK 48 horas após os EEM e da PSD imediatamente após os EEM, decorrentes da primeira sessão. No GB, a segunda sessão apenas provocou queda de PTI imediatamente após os EEM, enquanto no GP houve aumento significante apenas na PSD imediatamente após a segunda sessão de EEM. Apenas a CK apresentou EP para ambos os grupos. Pudemos concluir que o EP foi maior para o GB em comparação com o GP. Esse fenômeno pode ter ocorrido em detrimento da existência de um EP prévio para o GP, uma vez que este membro realiza contrações excêntricas intensas com maior freqüência no dia-a-dia, quando comparados com os GB.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silica gels were preparated from fixed proportion mixtures of tetraethoxysilane, water and hydrocloric acid, using either ultrasound stimulation (US) or conventional method (CO) in the hydrolysis step of the process. Wet gets were obtained with the same silica volume concentration and density. According to small-angle X-ray scattering, the structure of the wet gels can be described as mass fractal structures with mass fractal dimension D = 2.20 in a length scale xi = 7.9 nm, in the case of wet gels US, and D = 2.26 in a length scale 6.9 nm, in the case of wet gels CO. The mass fractal characteristics of the wet gels US and CO account for the different structures evolved in the drying of the gels US and CO in the obtaining of xerogels and aerogels. The pore structure of the dried gels was studied by nitrogen adsorption as a function of the temperature. Aerogels (US and CO) present high porosity with pore size distribution (PSD) curves in the mesopore region while xerogels (US and CO) present minor porosity with PSD curves mainly in the micropore region. The dried gels US (aerogels and xerogels) generally present pore volume and specific surface area greater than the dried gels CO. The mass fractal structure of the aerogels has been studied from an approach based on the PSD curves exclusively. (c) 2005 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method incorporating nested collision-induced dissociation/post-source decay (CID/PSD) combined with endopeptidase digestion is described as an approach to determine the sequence of N-terminally modified peptides. The information from immonium and related ions observed in the CID/PSD spectrum was used for the selection of a suitable endopeptidase for the digestion of peptides. Rapid and reliable assignment of peptide sequence was performed by the comparison of CID/PSD spectra of both intact and endopeptidese-digested peptide fragments, since the assignments of the observed fragment ions to either N- or C-terminal ions can thus be carried out unambiguously. This nested CID/PSD method was applied to the sequence determination of two peptides from the solitary wasps Anoplius samariensis and Batozonellus maculifrons (pompilid wasps), which could not be sequenced by the Edman method due to N-terminal modification. Copyright (C) 2002 John Wiley Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heterogeneity of variances for milk yield (MY) was determined for Brazilian and Colombian herds. The herds were grouped as high or low variability within each country, using as criterion the phenotypic standard deviation (PSD) of MY in the contemporary groups of cows, from the first to the sixth calving. Brazilian and Colombian herds with PSD greater than 1,168 kg or 1,012 kg, respectively, were classified as high variability while the herd groups with values lower than those were classified as low variability. The genetic parameters for MY within each herd group were estimated using bivariate analysis in an animal model and the restricted maximum likelihood method with a derivative free algorithm, using 72,280 first lactations of cows, daughters of 1,880 sires. Heterogeneous variances were found, and Brazilian herds with high PSD had the greatest additive and residual genetic variances and heritability coefficients for MY. MY genetic correlation coefficients between herds of high and low variability within each country were 0.96 and 0.93 while between countries they varied from 0.72 to 0.81, suggesting that there was a reclassification of animals in the two countries and also heterogeneity of variances. This phenomenon leads to the questioning of the strategy of imported semen usage and the need to do genetic evaluations to identify sires with greater genetic potential for (sub) tropical environmental conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a novel and simple positive sequence detector (PSD), which is inherently self-adjustable to fundamental frequency deviations by means of a software-based PLL (Phase Locked Loop). Since the proposed positive sequence detector is not based on Fortescue's classical decomposition and no special input filtering is needed, its dynamic response may be as fast as one fundamental cycle. The digital PLL ensures that the positive sequence components can be calculated even under distorted waveform conditions and fundamental frequency deviations. For the purpose of validating the proposed models, the positive sequence detector has been implemented in a PC-based Power Quality Monitor and experimental results illustrate its good performance. The PSD algorithm has also been evaluated in the control loop of a Series Active Filter and simulation results demonstrate its effectiveness in a closed-loop system. Moreover, considering single-phase applications, this paper also proposes a general single-phase PLL and a Fundamental Wave Detector (FWD) immune to frequency variations and waveform distortions. © 2005 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em História - FCHS