102 resultados para Orbital fractures
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The orbit is an irregular conical cavity formed from 7 bones including the frontal, sphenoid, zygomatic, maxillary, ethmoid, lacrimal, and palatine bones. Fractures of the internal orbit can cause a number of problems, including diplopia, ocular muscle entrapment, and enophthalmos. Although muscle entrapment is relatively rare, diplopia and enophthalmos are relatively common sequelae of internal orbital fractures. Medial orbital wall fracture is relatively uncommon and represents a challenge for its anatomical reconstruction. In this context, autogenous bone graft has been the criterion standard to provide framework for facial skeleton and orbital walls. Therefore, it is possible to harvest grafts of varying size and contour, and the operation is performed through the bicoronal incision, which is the usual approach to major orbital reconstruction. Thus, this article aimed to describe a patient with a pure medial orbital wall fracture, and it was causing diplopia and enophthalmos. The orbital fracture was treated using autogenous bone graft from calvarial bone. The authors show a follow-up of 12 months, with facial symmetry and without diplopia and enophthalmos. In addition, a computed tomography scan shows excellent bone healing at the anterior and posterior parts of the medial orbital wall reconstruction. Copyright © 2013 by Mutaz B. Habal, MD.
Resumo:
The aim of the present study was to analyze the etiology, type and treatment employed in the orbito-zygomatic fractures (OZ). Also, postoperative complications are described and correlated with the type of treatment used. Fifty patients with OZ fractures were evaluated. Orbital fractures in which the zygomatic bone was not involved were excluded. Epidemiologic data and characteristics of treatment such as the type of material used for osteosynthesis, number of anatomical sites on which rigid internal fixation (RIF) was applied, surgical approaches and associated complications were recorded. The main causes of trauma were motorcycle and bicycle accidents, constituting 52% of the sample. The osteosynthesis system used was the 2.0 mm, except in four patients in whom the 1.5mm system was used for fixation at the infra-orbital rim. A total of 18% of the patients required reconstruction of the internal orbit and in all cases titanium mesh was used. 46% of the patients received RIF in three anatomical sites, most in the fronto-zygomatic suture, infra-orbital rim and zygomatic-maxillary buttress. The most frequent complication was paresthesia of the infra-orbital nerve (34 patients, 68%). Other findings were also discussed with the intent of better understanding the treatment of the OZ fractures.
Resumo:
The aim of this study was to evaluate the efficacy and safety of traumatic orbital defect reconstruction with titanium mesh. A retrospective study was made. Evaluations were made after a minimum postoperative follow-up of 12 months, looking for the main complications. Twenty-four patients were included in this evaluation; 19 were male (79.1%) and 5 (20.8%) were female. The main injury etiology was vehicle accidents (50%) followed by other causes. Fourteen patients (58.3%) presented orbital floor fractures, and 10 had more than one wall fractured (41.6%). Permanent infraorbital nerve hypoesthesia was observed in two patients (8.3%), enophthalmos occurred in five patients (20.8%), and exophthalmos was found in two patients (8.3%). Four patients (16.6%) still presented evidence of residual prolapsed intraorbital content, and one of those needed further surgical correction; sinusitis occurred in one patient (4.1%). Titanium mesh is a reliable option for orbital reconstruction, despite some complications found in this sample.
Resumo:
Purpose: This study intends to evaluate BMP (Bone Morphogenetic Protein) implant and BMP implant plus PRP (Platelet Rich Plasma) in rabbit orbital fractures, searching for tissue reaction, by radiological and morfometrical analysis. Methods:Third six white rabbits were submitted to orbital floor fracture and distributed in three groups: G1, with rabbits receiving a plate containing decalcified bone matrix and BMP; G2, with rabbits receiving the implant with BMP wrapped by PRP; G3, the control group where it was made the fracture only. The animals were evaluated radiologically after surgery and at sacrifice time in 7, 30, 90 and 180th day after surgery. After sacrifice, a block containing the right orbital tissue was extracted and prepared to morphological and morphometrical analysis. Results: An intensive linfomononuclear inflammatory reaction was observed at 7th day in G1 e G2, witch decreased after the 30th day; mesenchimal cells, osteoblasts, new bone and progressive cavitation of the implant were also observed, besides signs of calcium deposition by radiological study. In the control group fibrosis at the site of fracture was identified only. Conclusion: BMP seemed a good orbital implant producing new bone at the implant site and correcting bone defect.There was not observed acceleration of osteoinduction when the implant was associated with PRP.
Resumo:
Purpose: To evaluate a bone morphogenetic protein (BMP) implant with and without platelet-rich plasma (PRP), which is supposed to accelerate fracture consolidation in the orbit fracture treatment. Methods: Thirty-six white rabbits were subjected to orbital fracture and treated in three groups: BMP implant fracture repair (G1), BMP plus PRP implant fracture repair (G2), and fracture and spontaneous repair (G3). The animals were sacrificed at 7, 30, 90, and 180 days after surgery. A radiology evaluation was carried out on the 7th day after the fracture and at the sacrifice moments. After the animals' death, the orbital content material was removed and prepared for morphological and morphometric analysis. Results: Radiology suggested intramembranous and progressive cavitation and ossification without a reduction in implant size and with signs of calcium deposition; these events were confirmed by histological analysis, which showed a lymphomononuclear inflammatory reaction in G1 and G2, more intense 7 days after surgery and reducing after 30 days. Associating PRP with BMP did not accelerate bone induction. Conclusion: BMP implant promotes bone induction, integration at fracture site, scarce inflammatory reaction, and may be a good alternative in orbit fracture reconstruction. The addition of PRP to the BMP plate did not accelerate the resolution, and its use is not necessary. Copyright © Informa Healthcare USA, Inc.
Association of titanium mesh and bovine pericardium membrane in the treatment of severe enophthalmos
Resumo:
The blowout fractures may be classified as pure or impure depending on the associated structures. There are 2 main theories attempting to describe the mechanism of injury, the hydraulic, and blocking mechanism. The complications of this type of fracture may involve diplopia, enophthalmos, and ocular movement restriction. Several materials are available for the reconstruction of orbital floor, including the titanium mesh, which present great properties, such as easy modeling and stabilization, small thickness, and shape maintenance. There, however, are disadvantages such as the possibility of adherence formation. The aim of this report is to describe the case of a patient with an 8-month blowout fracture sequel, presenting extensive enophthalmos and treated by affixing a titanium mesh associated with bovine pericardium membrane in the orbital floor. Therefore, based on a 2-year follow-up, it was possible to observe how effective the association between these 2 materials in solving the case was.
Resumo:
The frontal sinus fractures are derived from accidents of great intensity. Are usually associated with fractures of the midface, including the naso-orbital fractures and zygomatic ethmoid. Several treatment modalities have been proposed. In this case it was used to access bicoronal reconstruction of the anterior frontal sinus, and restore contour fronto-naso-orbital-ethmoid with satisfactory results.
Resumo:
Fractures of the zygomaticomaxillary complex are among the most common face traumas. Based upon the complexity and great variety of reported diagnoses and treatments, the proposal of this study was to evaluate, clinically and radiographically, unilateral zygomatic fractures treated through internal rigid fixation with miniplates and screws of 1.5 mm. Material and Method: 15 patients with unilateral fractures of the zygomaticomaxillary complex were analyzed, and compared with 15 patients without fractures so that a comparative analysis of the area and the perimeter of the orbital cavities could be made, as well as the distance from the nasal point to the zygomatic prominence between both groups. Results: In the radiographic analysis, the both groups presented similarity in the perimeter and in the area of the orbital cavities. Concerning the distance from the nasal point to the zygomatic prominence, only the operated group showed a significant difference between the sides, even though clinically the observation of the asymmetry had been absent or discreet. Conclusions: The treatment of unilateral fractures of the zygomaticomaxillary complex with the use of plates and screws of the 1.5 mm system proved to be effective, showing good esthetic results and low complication rates.
Resumo:
Reports of Toxocara canis ocular larva migrans are uncommon in animals, with only a few cases reported. Most reports involve larval migration into the retina and choroid, with parasitic invasion of the orbit reported only in experimental studies. This is the first clinical case of Toxocara canis infection in the retrobulbar region of a 10-year-old, cross-bred male dog presenting with unilateral orbital cellulitis. Ophthalmic signs included protrusion of the nictitating membrane, chemosis, exophthalmos and hypertropia. The parasite was diagnosed by histologic and parasitologic examination of orbital tissues, which were removed during enucleation.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A presença de algumas substâncias na água, como pigmentos fotossintetizantes, particulados, etc., afeta sua cor, provocando mudanças na radiância da água registrada por sensores orbitais. Nesse sentido, o sensoriamento remoto pode se constituir em uma fonte complementar de dados para o monitoramento da qualidade da água em grandes reservatórios (Novo et al., 1994). No contexto de um projeto de pesquisa realizado na AES Tietê S.A., com o objetivo de desenvolver técnicas para a avaliação da área com infestação de plantas aquáticas, imagens orbitais multiespectrais foram usadas tanto para mapear a dispersão espacial e estimar a área de ocorrência de macrófitas aquáticas, em duas épocas distintas, quanto para orientar a definição de pontos de amostragem in loco, visando a coleta e posterior análise da água e de sedimentos nos reservatórios. Este trabalho apresenta uma descrição do procedimento metodológico adotado na análise das imagens multiespectrais, bem como os resultados obtidos na caracterização dos reservatórios de Barra Bonita, Bariri, Ibitinga, Promissão e Nova Avanhandava, em termos de seu dimensionamento, variabilidade espectral da água e presença de macrófitas emersas, nas duas épocas do ano consideradas.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)