43 resultados para Nylon Deterioration
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
It is fundamentally important that adequate tests are used to evaluate the physiological quality of produced and commercialized seeds. The objective of this work was to study accelerated ageing and controlled deterioration to evaluate seed vigour in beetroot, seeking to associate these results with seedling emergence in the field. Consequently, five seed lots of Top Tall Early Wonder cultivar were submitted to the tests of germination, seedling emergence in the field, accelerated ageing (using periods of 24, 48 and 72 hours at 42 degrees C) and controlled deterioration (seeds with moisture contents of 22, 24 and 26% at 41 degrees C and 45 degrees C for 12, 24 and 36 hours). Combinations of 72h at 42 degrees C for the accelerated ageing test and 45 degrees C with 24% moisture content for 24h for the controlled deterioration test were sensitive enough to evaluate the physiological potential of beetroot seeds, providing information that was compatible with results of the seedling emergence in the field.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The failure of facial prostheses is caused by limitations in their flexibility and durability. Therefore, we evaluated the effects of disinfection and aging on Shore A hardness and deterioration of a facial silicone with different pigmentations. Twenty samples with addition of each pigment (ceramic (C), make-up (M)) and without pigment (L) were made. For each pigment type and no pigment, 10 samples were subjected to two types of disinfectant solution (soap (S) and Efferdent (E)), totaling sixty samples. The specimens were disinfected three times per week for 60 days, and subjected to accelerated aging for 1008 h. The hardness of the facial silicone was measured with a durometer, and its deterioration was evaluated by obtaining the weight difference over time. Both the hardness and weight of the samples were measured at baseline, after chemical disinfection, and periodically during accelerated aging (252, 504, and 1008 h). Deterioration was calculated during the periods between baseline and chemical disinfection, and between baseline and each aging period. The results were analyzed using three-way repeated measures ANOVA and the Tukey's HSD Post-hoc test (alpha = 0.05). Specifically, samples containing pigment exhibited significantly higher hardness and deterioration values than those lacking pigment (P < 0.05). In addition, period of time (disinfection and accelerated aging) statistically increased the hardness and deterioration values of the silicone (P < 0.05). It can be concluded that both pigment and time statistically affected the hardness and deterioration of the silicone elastomer. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The toothbrush is an effective instrument for oral diseases prevention. The flexibility and status of bristles, as well as the size of the handle are fundamental for an effective toothbrushing. Thus, the assessment of physical characteristics of toothbrushes is important. This study evaluated the deterioration and wear of bristles of toothbrushes used by preschool children. For the sample selection, five elementary schools were assorted from a city of the São Paulo State northwest region, one from each city area. All toothbrushes used by preschool children who aged between 5 and 6 years old and who attended the assorted schools were visually analysed by two calibrated examiners, according to the criteria proposed by Rawls HR, Mkwayi-Tulloch NJ, Casella R, Cosgrove R (J Dent Res 1989; 12: 1781): 0 - it is impossible to state if the toothbrush was used or not; 1 - the bristles seem to be separated within some tufts; 2 - most tufts are separated, many cover other tufts and present a large number of curved and inclined bristles; 3 - most tufts are covered by others and bristles are folded and tipped. In total, 333 toothbrushes were evaluated. The data obtained revealed that 57.96% of the toothbrushes presented adequate condition for utilization (scores 0 and 1), whereas 42.04% presented inadequate bristles for their function (scores 2 and 3). It was concluded that a great number of toothbrushes presented deterioration of the bristles. Thus, there is the need to guide and promote awareness among teachers, parents and children as well as the need to replace toothbrushes.
Resumo:
Testicular biopsy has been a complementary technique for clinical and research purposes to evaluate reproductive function in males. However, hemorrhage, inflammation, degeneration, and adhesion are factors that might limit the use of this procedure. In order to minimize these potential problems, fibrin glue derived from snake venom, a tissue adhesive with sealing, hemostatic, and healing properties, was used in conjunction with bilateral testicular biopsy with the Tru-Cut needle and was compared with a more conventional technique that uses nylon suture. Thirty mature rams were randomly assigned to three groups of 10 animals each, as follows: nonsurgical control group (no scrotal surgery, or biopsy); biopsy + glue group (fibrin glue on puncture sites and skin incisions) and biopsy + suture group (compression with swab on puncture sites and suturing of skin incision). The surgeries of the rams in the biopsy groups were performed on the same day, which was designated Day 0 for all three groups. Data of scrotal circumference, number of spermatozoa per ejaculum, percentage of morphologically abnormal spermatozoa, spermatozoa motility, and serum testosterone concentrations from Days -7, 20, 40, 60, 80 and 100 were evaluated. There were no significant differences between groups within days for any of the parameters evaluated. In conclusion, the testicular biopsy procedure using the Tru-Cut needle in conjunction with conventional nylon suture or the more novel fibrin glue in rams did not affect any of the parameters of testicular function evaluated in this study and was shown to be relatively simple, safe and efficient. (C) 2002 Published by Elsevier B.V. B.V.
Resumo:
Polymer alloys have been used as an alternative to obtain polymeric materials with unique physical properties. Generally, the polymer mixture is incompatible, which makes it necessary to use a compatibilizer to improve the interracial adhesion. Nylon 6 (PA6) is an attractive polymer to use in engineering applications, but it has processing instability and relatively low notched impact strength. In this study, the acrylonitrile-butadiene-styrene (ABS) triblock copolymer was used as an impact modifier for PA6. Poly(methyl methacrylate-co-maleic anyhydride) (MMA-MA) and poly(methyl methacrylate-co-maleic methacrylate) (MMA-GMA) were used as compatibilizers for this blend. The morphology and impact strength of the blends were evaluated as a function of blend composition and the presence of compatibilizers. The blends compatibilized with maleated copolymer exhibited an impact strength up to 800 J/m and a morphology with ABS domains more efi8ciently dispersed. Moderate amounts of MA functionality in the compatibilizer (∼5%) and small amounts of compatibilizer in the blend (∼5%) appear sufficient to improve the impact properties and ABS dispersion. © 2002 Wiley Periodicals, Inc. J Appl Polym Sci 87.
Resumo:
The morphological, mechanical and rheological properties of nylon 6/acrylonitrile-butadiene-styrene blends compatibilized with MMA-MA [poly(methyl methacrylate-comaleic anhydride)] copolymers were studied. A twin screw extruder was used for melt-blended the polymers and the injection moulding process was used to mold the samples. The main focus was on nylon 6/ ABS blends compatibilized with one MMA-MA copolymer. This copolymer has PMMA segments that appear to be miscible with the styrene-acrylonitrile (SAN) phase of ABS and the anhydride groups can react with amine end groups of the nylon 6 (Ny6) to form graft copolymers at the interface between Ny6 and ABS rich phases. Tensile and impact and morphological properties were enhanced by the incorporation of this copolymer. Transmission electron microscopy (TEM) observations revealed that the ABS domains are finely dispersed in nylon 6 matrix and led to the lowest ductile-brittle transition temperatures and highest impact properties. It can be concluded that the MMA-MA copolymer is an efficient alternative for the reactive compatibilization and can be used as a compatibilizer for nylon 6/ABS blends.© 2003 Kluwer Academic Publishers.
Resumo:
The morphologies of nylon 6/acrylonitrile-butadiene-styrene blends compatibilized with a methyl methacrylate/maleic anhydride copolymer, with 3-20 wt % maleic anhydride, were examined by transmission electron microscopy. Some staining techniques were employed for identifying the various phases. The binary blends were immiscible and exhibited poor mechanical properties that stemmed from the unfavorable interactions among their molecular segments. This produced an unstable and coarse phase morphology and weak interfaces among the phases in the solid state. The presence of the copolymer in the blends clearly led to a more efficient dispersion of the acrylonitrile-butadiene-styrene phase and consequently optimized Izod impact properties. © 2003 Wiley Periodicals, Inc.
Resumo:
The ductile-brittle transition temperatures were determined for compatibilized nylon 6/acrylonitrile-butadiene-styrene (PA6/ABS) copolymer blends. The compatibilizers used for those blends were methyl methacrylate-co-maleic anhydride (MMA-MAH) and MMA-co-glycidyl methacrylate (MMA-GMA). The ductile-brittle transition temperatures were found to be lower for blends compatibilized through maleate modified acrylic polymers. At room temperature, the PA6/ABS binary blend was essentially brittle whereas the ternary blends with MMA-MAH compatibilizer were supertough and showed a ductile-brittle transition temperature at -10°C. The blends compatibilized with maleated copolymer exhibited impact strengths of up to 800 J/m. However, the blends compatibilized with MMA-GMA showed poor toughness at room temperature and failed in a brittle manner at subambient temperatures.
Resumo:
Nylon6 is an attractive polymer for engineering applications because it has reactive functionality through amine and carboxyl end groups that are capable of reacting. For this reason, it has been used a lot in polymeric blends. Blends of nylon6/ABS (acrylonitrile-butadiene-styrene) were produced using glycidyl methacrylate-methyl methacrylate (GMA-MMA) copolymers as compatibilizer. The binary blends were immiscible and exhibited poor mechanical properties that stemmed from the unfavorable interactions among their molecular segments. This produced an unstable coarse phase morphology and weak interfaces between the phases in the solid state. The presence of the copolymer in the blends clearly led to a more efficient dispersion of the ABS phase and consequently optimized Izod impact properties. However, the compatibilized blend showed poor toughness at room temperature and failed in a brittle manner at subambient temperatures. © 2005 Springer Science + Business Media, Inc.
Resumo:
Purpose: Staining of prosthodontic materials may result in patient dissatisfaction and additional expense for replacement. This study aimed to determine the color stability of two heat-cured denture base acrylic (Lucitone 550, Vipi Cril) and one nylon denture base resin (Transflex) after immersion in beverages. Materials and Methods: Forty disks of each resin (20.0-mm diameter, 3.0-mm thick) were prepared and stored in distilled water for 24 hours at 37°C. During that time (T 0), the color of all specimens was spectrophotometrically measured. Each specimen was immersed in coffee, cola, red wine, and distilled water as a means of control. After 15-day (T 1) and 30-day (T 2) periods of immersion, the color of the specimens was measured again. The CIE (Commission Internationale de L' Eclairage) L*a*b* system was used to determine mean ΔE (color changes) values for each material and compared statistically with two-way ANOVA and Bonferroni intervals at 0.95. Results: In ΔET 0T 1 and ΔET 0T 2 the most severe staining was apparent with red wine (p < 0.001), followed by coffee (p < 0.01), when compared to the specimens stored in distilled water. Transflex also showed significant color change after immersion in cola (p < 0.01). In ΔET 1T 2 only red wine promoted significant staining of all resins (p < 0.0001). Conclusion: Chromatic changes were exhibited by specimens immersed in red wine, followed by coffee. For Transflex, cola also promoted color changes. The values of color changes converted to National Bureau of Standard units showed them to be perceivable to the human eye. © 2011 by the American College of Prosthodontists.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The invention of a modified nylon mesh for structural reinforcement of dental prostheses is described, said modified nylon mesh comprising polyamide fibres and 0.3%-0.5% v/v silicon dioxide (SiO2), which enables chemical binding between the acrylic resin and the polyamide mesh in order to increase the strength of the resin/polyamide complex in said dental prosthesis.
Resumo:
Fractures of iliac body are generally consequences of traumas of great impact. These fractures lead to a lack of locomotor response and in specific cases, surgery is needed. Among the possible therapeutic lines, implants become a good option. In this paper, the authors used dog corpses to develop a surgery technique of iliac osteosynthesis, employing nylon clamps and bone cement of polymethylmethacrylate (PMMA). Sixteen hemi pelvises of eight dog corpses, which had its iliac bodies totally fractured previously, were utilized. The osteosynthesis was reached through the implantation of six nylon clamps, distributed equally between the bone fragments. With the use of the nylon clamps there were bone realignment and a contact surface to fixation of the biomaterial. The technique developed in corpses was easily executed, effective in reduction, alignment and stabilization of the fracture. The authors suggest more studies in vitro to evaluate immobilization resistance and functionality in dogs with this condition.
Resumo:
The aims of this study were (1) to synthesize and characterize random and aligned nanocomposite fibers of multi-walled carbon nanotubes (MWCNT)/nylon-6 and (2) to determine their reinforcing effects on the flexural strength of a dental resin composite.Nylon-6 was dissolved in hexafluoropropanol (10 wt%), followed by the addition of MWCNT (hereafter referred to as nanotubes) at two distinct concentrations (i.e., 0.5 or 1.5 wt%). Neat nylon-6 fibers (without nanotubes) were also prepared. The solutions were electrospun using parameters under low- (120 rpm) or high-speed (6000 rpm) mandrel rotation to collect random and aligned fibers, respectively. The processed fiber mats were characterized by scanning (SEM) and transmission (TEM) electron microscopies, as well as by uni-axial tensile testing. To determine the reinforcing effects on the flexural strength of a dental resin composite, bar-shaped (20 x 2 x 2 mm(3)) resin composite specimens were prepared by first placing one increment of the composite, followed by one strip of the mat, and one last increment of composite. Non-reinforced composite specimens were used as the control. The specimens were then evaluated using flexural strength testing. SEM was done on the fractured surfaces. The data were analyzed using ANOVA and the Tukey's test (alpha=5%).Nanotubes were successfully incorporated into the nylon-6 fibers. Aligned and random fibers were obtained using high- and low-speed electrospinning, respectively, where the former were significantly (p<0.001) stronger than the latter, regardless of the nanotubes'presence. Indeed, the dental resin composite tested was significantly reinforced when combined with nylon-6 fibrous mats composed of aligned fibers (with or without nanotubes) or random fibers incorporated with nanotubes at 0.5 wt%. (C) 2015 Elsevier Ltd. All rights reserved.