84 resultados para Nonlinear functional analysis

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Constrained systems in quantum field theories call for a careful study of diverse classes of constraints and consistency checks over their temporal evolution. Here we study the functional structure of the free electromagnetic and pure Yang-Mills fields on the front-form coordinates with the null-plane gauge condition. It is seen that in this framework, we can deal with strictu sensu physical fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermoeconomic Functional Analysis is a method developed for the analysis and optimal design of improvement of thermal systems (Frangopoulos, 1984). The purpose of this work is to discuss the cogeneration system optimization using a condensing steam turbine with two extractions. This cogeneration system is a rational alternative in pulp and paper plants in regard to the Brazilian conditions. The objective of this optimization consists of minimizing the global cost of the system acquisition and operation, based on the parametrization of actual data from a cellulose plant with a daily production of 1000 tons. Among the several possible decision variables, the pressure and temperature of live steam were selected. These variables significantly affect the energy performance of the cogeneration system. The conditions which determine a lower cost for the system are presented in conclusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper, a thermoeconomic functional analysis method based on the Second Law of Thermodynamics and applied to analyze four cogeneration systems is presented. The objective of the developed technique is to minimize the operating costs of the cogeneration plant, namely exergetic production cost (EPC), assuming fixed rates of electricity production and process steam in exergy base. In this study a comparison is made between the same four configurations of part I. The cogeneration system consisting of a gas turbine with a heat recovery steam generator, without supplementary firing, has the lowest EPC. (C) 2004 Published by Elsevier Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work aims with an approach for cogeneration plants evaluation based on thermoeconomic functional diagram analysis. The second law of thermodynamics is used to develop a methodology to analyse cogeneration systems, based on exergoeconomics evaluation. The thermoeconomic optimisation method developed is applied to allow a better configuration of the cogeneration plant associated to a university hospital. Also ecological efficiency is evaluated. The method was efficient and contributes for thermoeconomics modelling and analysis and can be applied to any sort of thermal system, especially those with combined heat and power in thermal parity. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a nonlinear dynamic analysis of a flexible portal frame subjected to support excitation, which is provided by an electro-dynamical shaker. The problem is reduced to a mathematical model of four degrees of freedom and the equations of motion are derived via Lagrangian formulation. The main goal of this study is to investigate the dynamic interactions between a flexible portal frame and a non-ideal support excitation. The numerical analysis shows a complex behavior of the system, which can be observed by phase spaces, Poincaŕ sections and bifurcation diagrams. © 2012 American Institute of Physics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this paper is to discuss the teachers' need, as autonomous professionals, to evaluate their own pratice. Considering that Descriptive Functional Analysis (DFA) may be a pedagogical method for analysis, implementation, and change of teachers' mathematics teaching practices, the objective of the present research was to teach repertoires compatible with DFA to two mathematics teachers in elementary schools of São Paulo state. When teachers are responsible for evaluation and self evaluation, they recognize themselves as fundamental agents of transformation in education.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Snake venom (sv) C-type lectins encompass a group of hemorrhagic toxins that are capable of interfering with blood stasis. A very well-studied svC-type lectin is the heterodimeric toxin, convulxin (CVX), from the venom of South American rattlesnake Crotalus durissus terrificus. CVX is able to activate platelets and induce their aggregation by acting via p62/GPVI collagen receptor. By using polymerase chain reaction homology screening, we have cloned several cDNA precursors of CVX subunit homologs. One of them, named crotacetin (CTC) beta-subunit, predicts a polypeptide with a topology very similar to the tridimensional conformations of other subunits of CVX-like snake toxins, as determined by computational analysis. Using gel permeation and reverse-phase high-performance liquid chromatography, CTC was purified from C. durissus venoms. CTC can be isolated from the venom of several C. durissus subspecies, but its quantitative predominance is in the venom of C. durissus cascavella. Functional analysis indicates that CTC induces platelet aggregation, and, importantly, exhibits an antimicrobial activity against Gram-positive and -negative bacteria, comparable with CVX.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dados de equilíbrio da umidade da polpa de manga foram determinados utilizando-se o método estático gravimétrico. As isotermas de adsorção e dessorção foram obtidas na faixa de 30-70 ºC e as atividades de água (a w) de 0,02 a 0,97. A utilização do modelo de GAB nos resultados experimentais, através da análise de regressão não linear, proporcionou um bom ajuste entre os dados experimentais e os valores calculados. O calor isostérico de sorção foi estimado a partir dos dados de equilíbrio de sorção, utilizando-se a equação de Clausius-Clayperon. Notou-se que os calores isostéricos de sorção crescem com o aumento da temperatura e pode ser bem ajustado através de uma relação exponencial. A teoria da compensação entalpia-entropia foi aplicada às isotermas de sorção e gráficos deltaH versus deltaS forneceram as temperaturas isocinéticas, indicando um processo de sorção entalpicamente controlado.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo do estudo foi avaliar a formação de classes ordinais a partir do ensino de uma única sequência de estímulos sob controle da numerosidade. Participaram cinco crianças na faixa etária de 4 a 5 anos. Os estímulos foram formas abstratas referentes à numerosidade de 1 a 5. Usou-se um procedimento de ensino por sobreposição de estímulos. Todos os participantes alcançaram o critério de acerto na linha de base. Nos testes de transitividade e conectividade, os cincos participantes responderam prontamente. Houve generalização para duas novas classes ordinais. Nos testes de manutenção três participantes apresentaram responder consistente e um dos participantes respondeu parcialmente. Este estudo é uma contribuição para o estabelecimento de uma análise funcional da aprendizagem de repertórios numéricos.