11 resultados para Noncontact cartographie endocavitaire
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Purpose: the objective of this study was to determine if the zona thinning (ZT) technique improved the rates of implantation and clinical pregnancy for patients aged, greater than or equal to38 years submitted to an ICSI program.Methods: A total of 100 patients submitted to ICSI and aged, greater than or equal to38 years were divided in a prospective and randomized manner into two groups: Group I - patients submitted to ZT (n = 50); a laser diode with 1.48 mum wavelength (Fertilaser) was used for the ZT procedure with 1-2 irradiations of 10 ms applied to four different positions on the zona pellucida (ZP) of each embryo to thin 60-90% of the ZP (each point with a 15-20 mum length of ZT). Group II - patients with no ZT (n = 50). In both groups, embryo transfer was performed on the second or third day.Results: the age of Group I patients (39.8 +/- 1.3) did not differ (p = 0.67) from that of Group II patients (40 +/- 1.9). The number of oocytes retrieved at metaphase II from Group I (6.4 +/- 4.2) and Group II (6.8 +/- 5) was similar (p = 0.94). Normal fertilization rates and cleavage rates were similar (p = 0.78 and p = 0.63, respectively) for Group I (71.5 +/- 22% and 96.7 +/- 11%) and Group II (73.5 +/- 19.7% and 96 +/- 11%, respectively). The number of embryos transferred was similar (p = 0.53) for the two groups (Group I = 3.1 +/- 1.3; Group II = 2.9 +/- 1.1). The thickness of the ZP of Group I embryos (16.9 +/- 2.4 mum) did not differ (p = 0.97) from that of Group II embryos (16.9 +/- 2.3 mum). The rates of embryo implantation and clinical pregnancy per embryo transfer were similar (p = 0.67, p = 0.61) for Group I (7 and 16%, respectively) and for Group II (8.2 and 22%, respectively).Conclusions: These results suggest that ZT in the population aged, 38 years may have no impact on ICSI success rates. However, this conclusion is limited to a situation in which length of the laser ZT was less than or equal to 20 mum and the laser was applied to four different positions.
Resumo:
Avaliou-se a espessura corneana central de 13 gatos normais com microscópio especular de não-contato Topcon SP-2000P e paquímetro ultra-sônico. Foi observado aumento da espessura corneana mensurada pelo paquímetro ultra-sônico comparado ao microscópio especular.
Resumo:
The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.
Resumo:
Background and Objectives. The adhesion of dental materials is important for the success of treatment. The aim of this study is to evaluate the bond strength of a composite resin applied with a self-etching adhesive system in different dentins after irradiation with Er:YAG and Nd:YAG lasers, observing their morphologic pattern using Scanning Electronic Microscopy (SEM). Materials and Methods. The buccal surface of 72 bovine incisors was worn until exposure of medium depth dentin. The specimens were divided into three groups; GI: normal, GII: demineralized and GIII: hypermineralized dentin. These were also divided into two subgroups; A-irradiated for 30 s with Er:YAG laser in noncontact mode at 40 mJ and 6 Hz and B- irradiated for 30 s with Nd:YAG laser in contact mode at 60 mJ and 10 Hz. The adhesive system Clearfil SE. Bond (Kuraray) and composite resin Tetric Ceram (Vivadent) were applied on the irradiated area by the incremental technique. After storage for 24 h in distilled water at 37 degrees C, the specimens were submitted to the shear strength test in a universal testing machine (EMIC) at a crosshead speed of 1.0 mm/min. Other specimens were made to be analyzed by SEM. Results. The results were statistically analyzed by Analysis of Variance and the Tukey test. Regardless of the type of dentin, the bond strength of specimens irradiated with the Nd:YAG laser (8,94 +/- 2,07) was higher compared to specimens irradiated with the Er:YAG laser (7,03 +/- 2,47); the highest bond strength was obtained for the group of hypermineralized dentin irradiated with the Nd:YAG laser. The SEM analysis showed that the Er:YAG laser caused opening of tubules and the Nd:YAG laser produced areas of fusion as well as regions of opening of dentinal tubules. Conclusions. The dentin showed different morphological patterns and the laser promote alterations on their surfaces, influencing the bond strength of the composite resin. (C) 2010 Laser Institute of America.
Resumo:
Statement of problem. During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis.Purpose. The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser.Material and methods. Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark oil the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degreesC). Analysis was performed on the following groups (n = 10): Group 1, high-speed handpiece without water cooling, Group 11, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 mum at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha = .05).Results. The average temperature rises were: 11.64degreesC (+/-4.35) for Group 1, 0.96degreesC (+/-0.71) for Group 11, and 2.69degreesC (+/-1.12) for Group III. There were no statistical differences between Groups 11 and III, both 11 and III differed from Group I significantly (P = .000 and P = .002, respectively).Conclusion. The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This study aimed to evaluate and correlate intraocular pressure (IOP), endothelial cell density (CD), and hexagonality (HEX), and the aqueous humor prostaglandin E-2 (PGE(2)) concentration in dogs with mature (MG, n = 8) and hypermature (HG, n = 8) cataracts. Eight laboratory beagles with no ocular abnormalities were included as a control group (CG). The IOP was measured using a digital applanation tonometer. Noncontact specular microscopy was used to evaluate CD and HEX. Samples of aqueous humor were used to determine prostaglandin E-2 concentration using enzyme-linked immunoassay. Data were compared by ANOVA and Bonferroni's multiple comparison test, and possible correlations among the PGE(2) aqueous concentration and corneal endothelium cell parameters were assessed by Person's test (P < 0.05). Average values of IOP (P = 0.45) and CD (P = 0.39) were not significantly different between MG, HM, and CG. Average values of HEX were lower, and PGE(2) concentration was increased in the MG and HG in comparison with CG (P < 0.05); however, such parameters did not change significantly between MG and HG (P > 0.05). PGE(2) values did not correlate with IOP, CD, and HEX in any group (P > 0.05). Although there were a small number of dogs studied, our results demonstrated that cataract progression from mature to hypermature did not have a significant change in PGE(2) aqueous concentration, IOP, corneal endothelial cell count, or morphology. In addition, PGE(2) concentration was not correlated with parameters of the corneal endothelium or IOP in dogs with mature or hypermature cataracts.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper is concerned with a modeling method that can be used for an experimental identification of a dynamic system. More specifically, an equivalent lumped element system is presented to represent in a unique and exact manner a complete proportional-derivative (PD) controlled servo positioning system having a flexible manipulator. The impedance and mobility approach is used to transform the P and D control gains to an electrical spring and an electrical damper, respectively. The impedance model method is used to transform the flexible manipulator to a coupled system between a single contact mass at the driving position and a series of noncontact masses each of which is connected to the contact mass via a resilient member. This method is applicable whenever the driving point response of such a manipulator is available. Experimental work is presented to support the theory developed.
Resumo:
The article discusses a proposal of displacement measurement using a unique digital camera aiming at to exploit its feasibility for Modal Analysis applications. The proposal discusses a non-contact measuring approach able to measure multiple points simultaneously by using a unique digital camera. A modal analysis of a reduced scale lab building structure based only at the responses of the structure measured with the camera is presented. It focuses at the feasibility of using a simple ordinary camera for performing the output only modal analysis of structures and its advantage. The modal parameters of the structure are estimated from the camera data and also by using ordinary experimental modal analysis based on the Frequency Response Function (FRF) obtained by using the usual sensors like accelerometer and force cell. The comparison of the both analysis showed that the technique is promising noncontact measuring tool relatively simple and effective to be used in structural modal analysis
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)