11 resultados para Naval Electronic Systems Engineering Activity (U.S.)

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The term human factor is used by professionals of various fields meant for understanding the behavior of human beings at work. The human being, while developing a cooperative activity with a computer system, is subject to cause an undesirable situation in his/her task. This paper starts from the principle that human errors may be considered as a cause or factor contributing to a series of accidents and incidents in many diversified fields in which human beings interact with automated systems. We propose a simulator of performance in error with potentiality to assist the Human Computer Interaction (HCI) project manager in the construction of the critical systems. © 2011 Springer-Verlag.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acidic phospholipase A(2) (PLA(2)) isoforms in snake venoms, particularly those from Bothrops jararacussu, have not been characterized. This article reports the isolation and partial biochemical, functional and structural characterization of four acidic PLA(2)s (designated SIIISPIIA, SIIISPIIB, SIIISPIIIA and SIIISPIIIB) from this venom. The single chain purified proteins contained 122 amino acid residues and seven disulfide bonds with approximate molecular masses of 15 kDa and isoelectric points of 5.3. The respective N-terminal sequences were: SIIISPIIA-SLWQFGKMIDYVMGEEGAKS; SIIISPIIB-SLWQFGKMIFYTGKNEPVLS; SIIISPIIIA-SLWQFGKMILYVMGGEGVKQ and SIIISPIIIB-SLWQFGKMIFYEMTGEGVL. Crystals of the acidic protein SIIISPIIIB diffracted beyond 1.8 Angstrom resolution. These crystals are monoclinic with unit cell dimensions of a = 40.1 Angstrom, b = 54.2 Angstrom and c = 90.7 Angstrom. The crystal structure has been refined to a crystallographic residual of 16.1% (R-free = 22.9%). Specific catalytic activity (U/mg) of the isolated acidic PLA(2)s were SIIISPIIA = 290.3 U/mg; SIIISPIIB = 279.0 U/mg; SIIISPIIIA = 270.7 U/mg and SIIISPIIIB = 96.5 U/mg. Although their myotoxic activity was low, SIIISPIIA, SIIISPIIIB and SIIISPIIIA showed significant anticoagulant activity. However, there was no indirect hemolytic activity. SIIISPIIIB revealed no anticoagulant, but presented indirect hemolytic activity. With the exception of SIIISPIIIB, which inhibited platelet aggregation, all the others were capable of inducing time-independent edema. Chemical modification with 4-bromophenacyl bromide did not inhibit the induction of edema, but did suppress other activities. (C) 2003 Editions scientifiques et medicales Elsevier SAS. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on literature review, electronic systems design employ largely top-down methodology. The top-down methodology is vital for success in the synthesis and implementation of electronic systems. In this context, this paper presents a new computational tool, named BD2XML, to support electronic systems design. From a block diagram system of mixed-signal is generated object code in XML markup language. XML language is interesting because it has great flexibility and readability. The BD2XML was developed with object-oriented paradigm. It was used the AD7528 converter modeled in MATLAB / Simulink as a case study. The MATLAB / Simulink was chosen as a target due to its wide dissemination in academia and industry. From this case study it is possible to demonstrate the functionality of the BD2XML and make it a reflection on the design challenges. Therefore, an automatic tool for electronic systems design reduces the time and costs of the design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes an electronic system implementation with two force plates, 24 load cells with strain gages, signal conditioning circuit, interfacing circuit and data acquisition system, designed for measuring plantar force distribution in patients. The system presented linear response, low hysteresis, with determination coefficient of 0.9997, precision better than 0,84% and resolution less than 0.5 N. The Measurements are presented on a computer screen and easier visualization to specialists, mainly physicians, physiotherapists and occupational therapists. Using the system, the distribution of weight in the plantar region of 100 normal subjects and 10 hemiplegic patients was investigated. There were determined the relationship between weight distribution on the right and left forefoot, hemiplegic patients and normal patients, with the implemented system. © 2013 Springer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aimed at the development and evaluation of a low cost electronic device in order to provide safety for farm tractor users. The major accident occurrence in agricultural surroundings is from farm tractor side bending. Therefore, this sensor was designed to detect and alert about it. The results were satisfying. © 2013 Taylor & Francis Group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper develops a novel full analytic model for vibration analysis of solid-state electronic components. The model is just as accurate as finite element models and numerically light enough to permit for quick design trade-offs and statistical analysis. The paper shows the development of the model, comparison to finite elements and an application to a common engineering problem. A gull-wing flat pack component was selected as the benchmark test case, although the presented methodology is applicable to a wide range of component packages. Results showed very good agreement between the presented method and finite elements and demonstrated the usefulness of the method in how to use standard test data for a general application. © 2013 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciência da Informação - FFC

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Herbal medicines have been widely used around the world since ancient times. The advancement of phytochemical and phytopharmacological sciences has enabled elucidation of the composition and biological activities of several medicinal plant products. The effectiveness of many species of medicinal plants depends on the supply of active compounds. Most of the biologically active constituents of extracts, such as flavonoids, tannins, and terpenoids, are highly soluble in water, but have low absorption, because they are unable to cross the lipid membranes of the cells, have excessively high molecular size, or are poorly absorbed, resulting in loss of bioavailability and efficacy. Some extracts are not used clinically because of these obstacles. It has been widely proposed to combine herbal medicine with nanotechnology, because nano-structured systems might be able to potentiate the action of plant extracts, reducing the required dose and side effects, and improving activity. Nanosystems can deliver the active constituent at a sufficient concentration during the entire treatment period, directing it to the desired site of action. Conventional treatments do not meet these requirements. The purpose of this study is to review nanotechnology- based drug delivery systems and herbal medicines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: This study evaluated the effect of light-activation on the antibacterial activity of dentin bonding systems. Methods: Inocula of Streptococcus mutans and Lactobacillus casei cultures were spread on the surface of BHI agar and the materials were applied and subjected or not to light-activation. Zones of bacterial growth inhibition around the discs were measured. Results: Excite, Single Bond and the bond of Clearfil SE Bond (SE) and Clearfil Protect Bond (CP) did not show any antibacterial activity. The strongest inhibitory activity was observed for the primers of CP and Prompt (PR) against S. mutans and the primers of SE and PB against L. casei. Conclusion: Light-activation significantly reduced or suppressed the antibacterial activity of the initially active uncured dentin bonding systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB