17 resultados para National Institute of Neurological and Communicative Disorders and Stroke.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a preconcentration and separation system based on continuous flow hydride generation is proposed to improve the determination of As and Se by total reflection X-ray fluorescence spectrometry. The generated hydrides are continuously separated from the liquid phase and collected in a chamber containing 250 mul of HCI/HNO3 1:1 (v/v) solution. Hydride generation conditions and collection of the hydrides were evaluated. Under optimised conditions, enrichment factors of 55 for As and 82 for Se were attained. Detection limits of 0.3 mug l(-1) for As and Se were obtained when 20 ml of sample was used. Analysis of a natural water standard reference material from National Institute of Standard and Technology (SRM-1640) was in agreement with the certified values at the 95% confidence level. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The contents of some nutrients in 35 Brazilian green and roasted coffee samples were determined by flame atomic absorption spectrometry (Ca, Mg, Fe, Cu, Mn, and Zn), flame atomic emission photometry (Na and K) and Kjeldahl (N) after preparing the samples by wet digestion procedures using i) a digester heating block and ii) a conventional microwave oven system with pressure and temperature control. The accuracy of the procedures was checked using three standard reference materials (National Institute of Standards and Technology, SRM 1573a Tomato Leaves, SRM 1547 Peach Leaves, SRM 1570a Trace Elements in Spinach). Analysis of data after application of t-test showed that results obtained by microwave-assisted digestion were more accurate than those obtained by block digester at 95% confidence level. Additionally to better accuracy, other favorable characteristics found were lower analytical blanks, lower reagent consumption, and shorter digestion time. Exploratory analysis of results using Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) showed that Na, K, Ca, Cu, Mg, and Fe were the principal elements to discriminate between green and roasted coffee samples. ©2007 Sociedade Brasileira de Química.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Iridium-, Ru-, and W-coated platforms were prepared by thermal treatment of the transversely heated graphite atomizer and investigated for the simultaneous determination of As, Bi, Pb, Sb, and Se in tap water by electrothermal atomic absorption spectrometry. The maximum pyrolysis temperature for As and Bi increased in a modifier sequence W < Ru < Ir. For Pb, Sb, and Se, this sequence was W < Ru, It. Calculated characteristic masses in the presence of It, Ru, and W were 35, 33, and 35 pg for As; 63, 51, and 52 pg for Bi; 50, 32, and 34 pg for Pb; 40, 35, and 31 pg for Sb; and 39, 39, and 93 pg for Se, respectively. Ruthenium was elected as the optimum modifier.Repeatability of the measurements was typically < 6%. Recoveries of As, Bi, Pb, Sb, and Se added to tap water samples varied from 79 to 109%. Accuracy was also checked by analysis of five certified reference materials (CRMs) from the National Institute of Standards and Technology (NIST1640 - Trace Elements in Natural Water; NIST 1643d Trace Elements in Water) and High Purity Standards (Trace Metals in Drinking Water Standards, lots #812708, #591107, and #710710). A paired t-test showed that the results for the CRMs were in agreement at the 95% confidence level with the certified values. The graphite tube lifetime was about 650 firings. multi-element determination is particularly challenging due to the necessity of carefully optimizing compromise conditions.Based on the considerations listed above, the aim of this paper was to evaluate the behavior of Ir, Ru, and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se. The performance of the proposed procedure was also verified after the ETAAS analysis of tap waters and reference materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and the ability of this immobilized material to separate Sb(III) and Sb(V) was investigated. A method based on sequential determination of total Sb (after on-line reduction of Sb(V) to Sb(III) with thiourea) and Sb(Ill) (after on-line solid-liquid phase extraction) by hydride generation inductively coupled plasma optical emission spectrometry is proposed. A flow system assembled with solenoid valves was used to manage all stages of the process. The effects of pH, sample loading and elution flow rates on solid-liquid phase extraction of Sb(III) were evaluated. Also, the parameters related to online pre-reduction (reaction coil and flow rates) were optimized. Detection limits of 0.8 and 0.15 mu g L-1 were obtained for total Sb and Sb (III), respectively. The proposed method was applied to the analysis of river water and effluent samples. The results obtained for the determination of total Sb were in agreement with expected values, including the river water Standard Reference Material 1640 certified by the National Institute of Standards and Technology (NIST). Recoveries of Sb(III) and Sb(V) in spiked samples were between 81 19 and I I I 15% when 120 s of sample loading were used. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method is described for the simultaneous determination of Cd, Cr, Ni and Pb in mineral water samples by graphite furnace atomic absorption spectrometry with a transversely heated graphite atomizer (THGA) and a longitudinal Zeeman-effect background correction system. The electrothermal behavior of analytes during pyrolysis and atomization steps was studied without modifier, in presence of 5 μg Pd and 3 μg Mg(NO3)2 and in presence of 50 μg NH4H2PO4 and 3 μg Mg(NO3)2. A volume of 20 μL of a 0.028 mol L -1 HNO3 solution containing 50 μg L-1 Ni and Pb, 10 μg L-1 Cr and 5 μg L-1 Cd was dispensed into the graphite tube at 20°C. The mixture palladium/magnesium was selected as the optimum modifier. The pyrolysis and atomization temperatures were fixed at 1000°C and 2300°C, respectively. The characteristic masses were calculated as 2.2 pg Cd, 10 pg Cr, 42 pg Ni and 66 pg Pb and the lifetime of the graphite tube was around 600 firings. Limits of detection based on integrated absorbance were 0.02 μg L-1Cd, 0.94 μg L-1 Cr, 0.45 μg L-1 Ni and 0.75 μg L-1 Pb, which exceeded the requirements of Brazilian Food Regulation that establish the maximum permissible level for Cd, Cr, Ni and Pb at 3 μg L-1, 50 μg L-1, 20 μg L-1 and 10 μg L-1, respectively. The recoveries of Cd, Cr, Ni and Pb added to mineral water samples varied within the 93-108%, 96-104%, 87-101% and 98-108% ranges, respectively. Results of analysis of standard reference materials (National Institute of Standards and Technology: 1640-Trace Elements in Natural Water; 1643d-Trace Elements in Water) were in agreement with certified values at the 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Brazilian Network for Continuous Monitoring of GNSS - RBMC is a national network of continuously operating reference GNSS stations. Since its establishment in December of 1996, it has been playing an essential role for the maintenance and user access of the fundamental geodetic frame in the country. In order to provide better services for RBMC, the Brazilian Institute of Geography and Statistics - IBGE and the National Institute of Colonization and Land Reform - INCRA are both partners involved in the National Geospatial Framework Project - PIGN. This paper provides an overview of the recent modernization phases the RBMC network has undergone highlighting its future steps. These steps involve the installation of new equipment, provide real time data from a group of core stations and compute real-time DGPS corrections, based on CDGPS (The real-time Canada-Wide DGPS Service) (The Real-Time Canada-Wide DGPS Service. http://www.cdgps.com/ 2009a). In addition to this, a post-mission Precise Point Positioning (PPP) service has been established based on the current Geodetic Survey Division of NRCan (CSRS-PPP) service. This service is operational since April 2009 and is in large use in the country. All activities mentioned before are based on a cooperation signed at the end of 2004 with the University of New Brunswick, supported by the Canadian International Development Agency and the Brazilian Cooperation Agency. The Geodetic Survey Division of NRCan is also participating in this modernization effort under the same project. This infrastructure of 66 GNSS stations, the real time, post processing services and the potentiality of providing Wide Area DGPS corrections in the future show that the RBMC system is comparable to those available in USA and Europe. © Springer-Verlag Berlin Heidelberg 2012.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Block diagrams and signal-flow graphs are used to represent and to obtain the transfer function of interconnected systems. The reduction of signal-flow graphs is considered simpler than the reduction of block diagrams for systems with complex interrelationships. Signal-flow graphs reduction can be made without graphic manipulations of diagrams, and it is attractive for a computational implementation. In this paper the authors propose a computational method for direct reduction of signal-flow graphs. This method uses results presented in this paper about the calculation of literal determinants without symbolic mathematics tools. The Cramer's rule is applied for the solution of a set of linear equations, A program in MATLAB language for reduction of signal-flow graphs with the proposed method is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of this article are to provide a short history of dentistry and dental education in Brazil and to analyze the nature of its development to date. The databases consulted are those provided by the Brazilian Federal Council of Dentistry, Brazilian Ministry of Health, Brazilian Ministry of Education, National Institute of Studies and Educational Research Anisio Teixeira, and Brazilian Institute of Geography and Statistics. Formal dental education in Brazil started in the late nineteenth century with the creation of courses annexed to existing schools of medicine in Rio de Janeiro and Bahia. Today, there are 191 institutions of higher education nationwide granting degrees in dentistry (137 private [71.7 percent] and fifty-four public [28.3 percent]), with a total of 17,157 student positions offered annually. These schools graduate around 10,000 professionals per year-one of the highest rates in the world. Both the distribution of schools of dentistry and of dentists varies among the regions of the country, with the greatest concentrations in major metropolitan centers with high population density, resulting in limited coverage in the more deprived regions. A review of epidemiological data for oral health and distribution of dentists in Brazil indicates that there is a lack of systematic planning for the allocation of the dental workforce and a lack of consideration of regional needs in the development of dental training programs in Brazil today.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A comprehensive analysis of electrodisintegration yields of protons on Zr90 is proposed taking into account the giant dipole resonance, isovector giant quadrupole resonance (IVGQR), and quasideuteron contributions to the total photoabsorption cross section from 10 to 140 MeV. The calculation applies the MCMC intranuclear cascade to address the direct and pre-equilibrium emissions and another Monte Carlo-based algorithm to describe the evaporation step. The final results of the total photoabsorption cross section for Zr90 and relevant decay channels are obtained by fitting the (e,p) measurements from the National Bureau of Standards and show that multiple proton emissions dominate the photonuclear reactions at higher energies. These results provide a consistent explanation for the exotic and steady increase of the (e,p) yield and also a strong evidence of a IVGQR with a strength parameter compatible with the E2 energy-weighted sum rule. The inclusive photoneutron cross sections for Zr90 and natZr, derived from these results and normalized with the (e,p) data, are in agreement within 10% with both Livermore and Saclay data up to 140 MeV. © 2007 The American Physical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work design criteria for cooling of electronic systems used in a digital transmission equipment are considered. An experimental study using a simulated electronic equipment in which vertically oriented circuit boards are aligned to form vertical channels is carried out. Resistors are used to simulate actual components. The temperature of several components in the printed circuit boards are measured and the influence of the baffles and shields on the cooling effect are discussed. It was observed that the use of the baffles reduce the temperature levels and, the use of shields, although protecting the components from magnetic effects, cause an increase in the temperature levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Piezoelectric transducers are widely used in high-resolution positioning systems. This paper reports the experimental analysis of a novel piezoelectric flextensional actuator (PFA), which is designed by using the topology-optimization method through a low-cost homodyne Michelson interferometer. By applying the J(1) - J(4) method for signal demodulation, which provides a linear and direct measurement of dynamic optical phase shift independent of fading, the nanometric displacements of the PFA were determined. Linearity and frequency response of the PFA were evaluated up to 50 kHz. PFA calibration factor and amplification rate were determined for the PFA operating in the quasi-static regime. To confirm the observed frequencies of resonance, an impedance analyzer is also utilized to measure the magnitude and phase of the PFA admittance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A transmission line is characterized by the fact that its parameters are distributed along its length. This fact makes the voltages and currents along the line to behave like waves and these are described by differential equations. In general, the differential equations mentioned are difficult to solve in the time domain, due to the convolution integral, but in the frequency domain these equations become simpler and their solutions are known. The transmission line can be represented by a cascade of π circuits. This model has the advantage of being developed directly in the time domain, but there is a need to apply numerical integration methods. In this work a comparison of the model that considers the fact that the parameters are distributed (Universal Line Model) and the fact that the parameters considered concentrated along the line (π circuit model) using the trapezoidal integration method, and Simpson's rule Runge-Kutta in a single-phase transmission line length of 100 km subjected to an operation power. © 2003-2012 IEEE.