71 resultados para NUSSELT NUMBER

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Laminar forced convection inside tubes of various cross-section shapes is of interest in the design of a low Reynolds number heat exchanger apparatus. Heat transfer to thermally developing, hydrodynamically developed forced convection inside tubes of simple geometries such as a circular tube, parallel plate, or annular duct has been well studied in the literature and documented in various books, but for elliptical duct there are not much work done. The main assumption used in this work is a laminar flow of a power flow inside elliptical tube, under a boundary condition of first kind with constant physical properties and negligible axial heat diffusion (high Peclet number). To solve the thermally developing problem, we use the generalized integral transform technique (GITT), also known as Sturm-Liouville transform. Actually, such an integral transform is a generalization of the finite Fourier transform where the sine and cosine functions are replaced by more general sets of orthogonal functions. The axes are algebraically transformed from the Cartesian coordinate system to the elliptical coordinate system in order to avoid the irregular shape of the elliptical duct wall. The GITT is then applied to transform and solve the problem and to obtain the once unknown temperature field. Afterward, it is possible to compute and present the quantities of practical interest, such as the bulk fluid temperature, the local Nusselt number and the average Nusselt number for various cross-section aspect ratios. (C) 2006 Elsevier. SAS. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a finite element numerical solution of free convection in a cavity with side walls maintained at constant but different temperatures. The predictions from the model and the method of solution were validated by comparison with the 'bench mark' solution and Vahl Davis' results and good agreement was found. The present model was used to obtain additional results over a wide range of Rayleigh number (10(3)-10(6)) and L/H ratios varying from 0.1 to 1.0. The predicted stream function patterns, temperature and velocity profiles as well as the mean Nusselt number were presented and discussed. (C) 2000 Elsevier B.V. Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, an analysis of the natural convection flow caused by heat sources dissipating energy at a constant rate simulating electronic components mounted at the bottom surface of a cavity symmetrically cooled from the sides and insulated at the top is performed. This problem was studied numerically and experimentally for several aspect ratios (height/width), for different levels of dissipation in the sources, and for different side wall temperatures. Temperature and velocity fields were determined as well as the temperature variation along the surface where the sources are mounted and the average Nusselt number in the source surfaces. Numerical and experimental results were found to agree.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this manuscript we investigated experimentally the steady-state heat transfer to an important pseudoplastic fluid food, the soursop juice, flowing in laminar regime through circular and concentric annular ducts. The mean convection heat transfer coefficients, determined by measuring the bulk temperatures before and after the heating sections with constant temperatures of the tube walls, were used to correlate simple new empiric expressions to estimate the average Nusselt number in the thermal entrance of the considered geometries. In addition, the thermophysical properties of the tested fluid food, as well as the rheological behavior, being essential for the heat transfer analyses, were experimentally determined. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work considers a problem of interest in several technological applications such as the thermal control of electronic equipment. It is also important to study the heat transfer performance of these components under off-normal conditions, such as during failure of cooling fans. The effect of natural convection on the flow and heat transfer in a cavity with two flush mounted heat sources on the left vertical wall, simulating electronic components, is studied numerically and experimentally. The influence of the power distribution, spacing between the heat sources and cavity aspect ratio have been investigated. An analysis of the average Nusselt number of the two heat sources was performed to investigate the behavior of the heat transfer coefficients. The results obtained numerically and experimentally, after an error analysis, showed a good agreement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Laminar-forced convection inside tubes of various cross-section shapes is of interest in the design of a low Reynolds number heat exchanger apparatus. Heat transfer to thermally developing, hydrodynamically developed forced convection inside tubes of simple geometries such as a circular tube, parallel plate, or annular duct has been well studied in the literature and documented in various books, but for elliptical duct there are not much work done. The main assumptions used in this work are a non-Newtonian fluid, laminar flow, constant physical properties, and negligible axial heat diffusion (high Peclet number). Most of the previous research in elliptical ducts deal mainly with aspects of fully developed laminar flow forced convection, such as velocity profile, maximum velocity, pressure drop, and heat transfer quantities. In this work, we examine heat transfer in a hydrodynamically developed, thermally developing laminar forced convection flow of fluid inside an elliptical tube under a second kind of a boundary condition. To solve the thermally developing problem, we use the generalized integral transform technique (GITT), also known as Sturm-Liouville transform. Actually, such an integral transform is a generalization of the finite Fourier transform, where the sine and cosine functions are replaced by more general sets of orthogonal functions. The axes are algebraically transformed from the Cartesian coordinate system to the elliptical coordinate system in order to avoid the irregular shape of the elliptical duct wall. The GITT is then applied to transform and solve the problem and to obtain the once unknown temperature field. Afterward, it is possible to compute and present the quantities of practical interest, such as the bulk fluid temperature, the local Nusselt number, and the average Nusselt number for various cross-section aspect ratios.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia e Ciência de Alimentos - IBILCE

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the remarkable karyotype of Dinoponera lucida, a Brazilian endemic ponerine ant. Its chromosome number is 2n=106, most of the chromosomes are acrocentric and of very small size, and the karyotype formula is 88A+18M. A chromosome pair of the AM(t) type is reported. This is the largest number of chromosomes reported for the Hymenoptera order until now.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foi avaliado o efeito dos fungos contaminantes Trichoderma sp. e C. olivacearum na produtividade, eficiência biológica e número de cogumelos da produção do A. blazei em composto (mistura de cana-de-açúcar, palha de capim coast-cross, farelo de soja, gesso e calcário calcítico). O delineanamento foi inteiramente casualizado com três tratamentos (Trichoderma sp., C. olivacearum e testemunha) e oito repetições (caixa com 12 kg de composto colonizado com A. blazei). Após a colonização do composto pelo A. blazei, adicionou-se 150g de inóculo à base de triticale de cada um dos fungos contaminantes na superfície do composto seguido da camada de cobertura. O experimento foi conduzido em estufa com cobertura plástica, umidade relativa entre 60-90% e temperatura de 20-34ºC. A produtividade foi determinada pela relação entre a massa fresca de basidiomas e a massa úmida do composto. A eficiência biológica foi determinada pela relação entre a massa fresca de basidiomas e a massa seca do composto ao final do período de colheita. de acordo com os resultados obtidos, os fungos contaminantes C. olivacearum e Trichoderma sp. não afetaram a produtividade, eficiência biológica e número de cogumelos da produção do A. blazei em compostos previamente colonizados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical cognition is based on two components - number processing and calculation. Its development is influenced by biological, cognitive, educational, and cultural factors. The objectives of the present study were to: i) assess number processing and calculation in Brazilian children aged 7-12 years from public schools using the Zareki-R (Battery of neuropsychological tests for number processing and calculation in children, Revised; von Aster & Dellatolas, 2006) in order to obtain normative data for Portuguese speakers; ii) identify how environment, age, and gender influences the development of these mathematical skills; iii) investigate the construct validity of the Zareki-R by the contrast with the Arithmetic subtest of WISC-III. The sample included 172 children, both genders, divided in two groups: urban (N= 119) and rural (N= 53) assessed by the Zareki-R. Rural children presented lower scores in one aspect of number processing; children aged 7-8 years demonstrated an inferior global score than older; boys presented a superior performance in both number processing and calculation. Construct validity of Zareki-R was demonstrated by high to moderate correlations with Arithmetic subtest of WISC-III. The Zareki-R therefore is a suitable instrument to assess the development of mathematical skills, which is influenced by factors such as environment, age, and gender.