167 resultados para NBR 15575 Standard

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality in construction is increasingly a concern in this sector, in view of the occurrence of problems in civil works, even when a contractor is certified by ISO 9001. The ISO 9001 certification does not ensure the maintenance of quality because it only establishes the requirements for a quality management system (QMS) to ensure standardization of processes and products. With the development of ISO 15575, standard performance, the builders took on a quality parameter with the requirements established by this Standard, which must be met. Thus, the implementation of a quality management system (QMS) becomes essential, showing users the concern for quality. This study aimed to verify, through a case study, the impact of NBR 15575 quality construction and how that standard of performance may be the key element of ISO 9001 to ensure quality maintenance of civil works

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The compaction rate, the relation between the density of the wood panel and the density of the wood used for producing the particles, is an indicator of the product's densification. Among the various types of wood panels, particleboards are widely employed in the lumber industry, mainly for the furniture production. This paper presents a study of the relation between the compaction rate and the properties of tensile strength perpendicular to surface, Modulus of Rupture (MOR) and Modulus of Elasticity (MOE) obtained from a static bending test, thickness swelling and water absorption (2 and 24 hours). These properties were calculated according to the Brazilian ABNT, NBR 14810 standard. Particleboards were produced using the species Pinus elliotti and adhesive ureaformaldehyde. The relation was established by a multiple linear regression, and the most appropriate statistical models were determined. The estimated models indicate statistically significant effects of water absorption in 2 hours and MOR in the particleboards' compaction rate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The broader knowledge about physical and mechanical properties of wood allows reliable timber structures design. Even little addressed in the literature, in several situations Poisson's ratios are required for the evaluation of stresses acting on structural elements. This study aimed to obtain values of Poisson's ratios (ν), plans Longitudinal-Radial (νLR) and Longitudinal-Tangential (νLT), for species Peroba Rosa (Aspidosperma polyneuron) and Jatobá (Hymenaea courbaril L.). For this purpose, forty samples Peroba Rosa and eight samples of Jatobá were prepared for testing in compression parallel to the grain, following the recommendations of ABNT NBR 7190 standard. The results of means confidence intervals, considered at the level of 5% significance, revealed that the Poisson's ratios νLR e νLT to Peroba Rosa are 0.27 and 0.42, respectively, and 0.25 and 0.43 to Jatobá.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study is to perform a situational analysis of the Laboratory of pulp and paper-UNESP ITAPEVA for conducting proposal the accreditation according to ISO / IEC 17025:2005. The ISO / IEC 17025 establishes the criteria for those laboratories wishing to demonstrate their technical competence, which have an effective quality system and are able to generate technically valid results, establishing a single international standard for certifying the competence of laboratories to carry tests and / or calibrations, including sampling. The case study was conducted on laboratory Pulp and Paper Universidade Estadual Paulista (UNESP), campus Itapeva, where we compared the views of the technician responsible for the laboratory and a regular user. The generated conclusion is that the laboratory is unable to initiate an accreditation process, because it fails the requirements such as quality manual, register of subcontractors, research of customer satisfaction, schedule of internal audits, schedule for completion of critical analysis, profile of the functions required, functions current description, documentation of technical requirements for accommodation and environmental conditions, calibration programs, equipment calibration program, programs calibration standards and reports and / or certificate of test and / or calibration, that are in accordance with ISO / IEC 17025:2005, beyond that there is not the possibility to develop and implement a quality system without the commitment of everyone involved, regardless of the functional hierarchy

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of environmental management systems - EMS has shown to be a key tool for addressing the environmental aspects and impacts of an organization. The vast majority of EMS based on the requirements of ISO 14001:2004, as it is a globally recognized standard and adopt its recommendations is considered to be a guarantee of fulfilling the basic requirements of an EMS. Despite all the benefits that the system provides, we still find many problems in the implementation of EMS, especially in small and medium enterprises or SME. Most of the difficulties of implementation is related to intrinsic factors that companies of this size have, and issues related to the models and methods used to implement an EMS. Thus, this work aimed to assess whether the guidelines of ISO 14005:2012 meet the needs of SMEs for the effective implementation of an environmental management system. For it has been identified in the relation between SMEs and EMS the majof intrinsic problems of SMEs to implement (PII), such as lack of financial and human resources, and lack of commitment from top management to the SGA. Also was also pointed the main implementation issues related to ISO 14001 (ABNT, 2004) or the models or methods (PIM), highlighting the lack of environmental performance criteria, and the need for a path or sequence of steps for implementation. The study of ISO 14005 (ABNT, 2012) showed that the standard guidelines and implementation examples proposed, include solutions for all problems related to EMS implementation SMEs

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I- 100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artigo apresenta valores eletrocardiográficos de 25 bezerros da raça Holandesesa, utilizando-se as derivações bipolares de membro (I, II, III), unipolares aumentadas de membro (avL, avR e avF) e uma derivação bipolar de torax (V10). Dois grupos com animais de diferentes idades foram comparados (18 a 72 horas e 27 a 33 dias de idade). Conclui-se que não houve diferença significativa entre os grupos nas ondas P, Q, R, S e T, nos intervalos PR, QRS, QT e ST e no eixo cardíaco.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthogonality criterion is used to show in a very simple and general way that anomalous bound-state solutions for the Coulomb potential (hydrino states) do not exist as bona fide solutions of the Schrodinger, Klein-Gordon and Dirac equations. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the construction of a homogeneous phantom to be used in simulating the scattering and absorption of X-rays by a standard patient chest and skull when irradiated laterally. This phantom consisted of Incite and aluminium plates with their thickness determined by a tomographic exploratory method applied to the anthropomorphic phantom. Using this phantom, an optimized radiographic technique was established for chest and skull of standard sized patient in lateral view. Images generated with this optimized technique demonstrated improved image quality and reduced radiation doses. (c) 2006 Elsevier Ltd. All rights reserved.