12 resultados para Movement Pattern

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Locomotion generates a visual movement pattern characterized as optic flow. To explore how the locomotor adjustments are affected by this pattern, an experimental paradigm was developed to eliminate optic flow during obstacle avoidance. The aim was to investigate the contribution of optic flow in obstacle avoidance by using a stroboscopic lamp. Ten young adults walked on an 8m pathway and stepped over obstacles at two heights. Visual sampling was determined by a stroboscopic lamp (static and dynamic visual sampling). Three-dimensional kinematics data showed that the visual information about self-motion provided by the optic flow was crucial for estimating the distance from and the height of the obstacle. Participants presented conservative behavior for obstacle avoidance under experimental visual sampling conditions, which suggests that optic flow favors the coupling of vision to adaptive behavior for obstacle avoidance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Proprioceptive neuromuscular facilitation (PNF) is an attractive method to increase strength and proprioception of elderly individuals. However, a major clinical concern about the prescription of PNF is the belief that it can cause a cardiovascular overload, because it involves close-to-maximal loads and isometric contractions. Yet the acute effect of a PNF training session on cardiovascular response in elderly individuals is still unknown. Hence, the objective of this study was to evaluate the effect of PNF on diastolic and systolic blood pressure of healthy elderly people. Fifteen older women (mean age 72.40±6.82 years) performed three sets (five repetitions each) of three different PNF techniques (rhythmic initiation, dynamic reversion, and isotonic combination), executing a single movement pattern. Diastolic and systolic blood pressure (DBP and SBP) were evaluated by means of a manual sphygmomanometer immediately before and during the last two repetitions (last set) of each technique. A two-way ANOVA test (time and technique) was performed to investigate the PNF effect on blood pressure. No time (preexercise to postexercise) (p=0.33 for DBP; p=0.06 for SBP) or PNF technique (p=0.75; p=0.81) effect were observed. In conclusion, we can state that the execution of these PNF techniques is safe for the cardiovascular system of healthy elderly women, because no blood pressure increases were found. Copyright © Informa Healthcare USA, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A number of studies have analyzed various indices of the final position variability in order to provide insight into different levels of neuromotor processing during reaching movements. Yet the possible effects of movement kinematics on variability have often been neglected. The present study was designed to test the effects of movement direction and curvature on the pattern of movement variable errors. Subjects performed series of reaching movements over the same distance and into the same target. However, due either to changes in starting position or to applied obstacles, the movements were performed in different directions or along the trajectories of different curvatures. The pattern of movement variable errors was assessed by means of the principal component analysis applied on the 2-D scatter of movement final positions. The orientation of these ellipses demonstrated changes associated with changes in both movement direction and curvature. However, neither movement direction nor movement curvature affected movement variable errors assessed by area of the ellipses. Therefore it was concluded that the end-point variability depends partly, but not exclusively, on movement kinematics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design of the present study enabled the authors to distinguish between the possible effects of movement displacement and trajectory length on the pattern of final positions of planar reaching movements. With their eyes closed, 9 subjects performed series of fast and accurate movements from different initial positions to the same target. For some series, the movements were unconstrained and were therefore performed along an approximately straight vertical line. For other series, an obstacle was positioned so that trajectory length was increased because of an increase in movement curvature. Ellipses of variability obtained by means of principal component analysis applied to the scatter of movement final positions enabled the authors to assess the pattern of movement variable errors. The results showed that the orientation of the ellipses was not affected by movement displacement or by trajectory length, whereas variable errors increased with move ment displacement. An increase in trajectory length as a consequence of increased curvature caused no change in variable error. From the perspective of current motor control theory, that finding was quite unexpected. Further studies are required so that one can distinguish among the possible effects of various kinematics, kinetics, and other variables that could affect the pattern of variable errors of reaching movements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mucosa that covers the residual ridges of edentulous patients may present some distortion or displacement when occlusal loading is applied in complete dentures. This distortion and movement of the denture can result in acceleration of residual ridge resorption and loss of retention and stability. The aim of this study was to analyze the pattern of upper complete denture movement related to underlying mucosa displacement. A sample of 10 complete denture wearers was randomly selected, which had acceptable upper and lower dentures and normal volume and resilience of residual ridges. The kinesiographic instrument K6-I Diagnostic System was used to measure denture movements, according to the method proposed by Maeda et al.7, 1984. Denture movements were measured under the following experimental conditions: (A) 3 maximum voluntary clenching cycles and (B) unilateral chewing for 20 seconds. The results showed that under physiological load, oral mucosa distortion has two distinct phases: a fast initial displacement as load is applied and a slower and incomplete recovery when load is removed. Intermittent loading such as chewing progressively reduces the magnitude of the denture displacement and the recovery of the mucosa is gradually more incomplete.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It was purposed the use of electromyography (EMG) to evaluate the activation of the agonists and antagonists muscles of spastic patients, to test the viability in the development of an instrument that given quantitative data of the patient spasticity. 30 hemiplegic and 15 normal volunteers had been submitted to the EMG of flexor and extensor carpi ulnaris muscles during the flexion and extension movements of the wrist. The individuals with less severe spasticity (mAS (modified Ashworth Scale) ringing 0 to 3 degree), had presented deficit in the activation of the flexor muscles in plegic side in relation to the non plegic side and that the individuals seriously compromised by the spasticity (mAS = 4 degree) present deficit of reciprocal inhibition. One evidenced is that the non plegic member does not present a similar neuro-motor comportment when compared to the normal member. The surface electromyography is a practical clinical instrument to evaluate the patient with spasticity and the hemiplegic patient needs to be evaluated on both sides (deficient and no deficient) because the no compromised side do not show a normality standard.