12 resultados para Morbus Fabry
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Anderson-Fabry disease is an X-linked defect of glycosphingolipid metabolism. Progressive renal insufficiency is a major source of morbidity, additional complications result from cardio- and cerebro-vascular involvement. Survival is reduced among affected males and symptomatic female carriers. To evaluate the effectiveness and safety of enzyme replacement therapy compared to other interventions, placebo or no interventions, for treating Anderson-Fabry disease. We searched 'Clinical Trials' on The Cochrane Library, MEDLINE, EMBASE, LILACS and the Cystic Fibrosis and Genetic Disorders Group's Inborn Errors of Metabolism Trials Register (date of the most recent search: 11 September 2012). The original search was performed in September 2008.Date of the most recent search of the Cystic Fibrosis and Genetic Disorders Group's Inborn Errors of Metabolism Trials Register: 11 September 2012. Randomized controlled trials of agalsidase alfa or beta in participants diagnosed with Anderson-Fabry disease. Two authors selected relevant trials, assessed methodological quality and extracted data. Six trials comparing either agalsidase alfa or beta in 223 participants fulfilled the selection criteria.Both trials comparing agalsidase alfa to placebo reported on globotriaosylceramide concentration in plasma and tissue; aggregate results were non-significant. One trial reported pain scores, there was a statistically significant improvement for participants receiving treatment at up to three months, mean difference -2.10 (95% confidence interval (CI) -3.79 to -0.41); at up to five months, mean difference -1.90 (95% CI -3.65 to -0.15); and at up to six months, mean difference -2.00 (95% CI -3.66 to -0.34). There was a significant difference in pain-related quality of life at over five months and up to six months, mean difference -2.10 (95% CI -3.92 to -0.28) but not at other time-points. Neither trial reported deaths.One of the three trials comparing agalsidase beta to placebo reported on globotriaosylceramide concentration in plasma and tissue and showed significant improvement: kidney, mean difference -1.70 (95% CI -2.09 to -1.31); heart, mean difference -0.90 (95% CI -1.18 to -0.62); and composite results (renal, cardiac, and cerebrovascular complications and death), mean difference -4.80 (95% CI -5.45 to -4.15). There was no significant difference between groups for death; no trials reported on pain.Only one trial compared agalsidase alfa to agalsidase beta. There was no significant difference between the groups for any adverse events, risk ratio 0.36 (95% CI 0.08 to 1.59), or any serious adverse events; risk ratio 0.30; 95% CI 0.03 to 2.57). Six small, poor quality randomised controlled trials provide no robust evidence for use of either agalsidase alfa and beta to treat Anderson-Fabry disease.
Resumo:
No Zoológico Nacional do Parque Metropolitano de Santiago, Chile, foram encontrados dois psitacídeos Enicognathus leptorhynchus, mortos pelo nematódeo Ascaridia hermaphrodita (Froelich, 1789). Este é o primeiro registro desse nematódeo em E. leptorhynchus e também o primeiro registro deste parasito no Chile.
Resumo:
In this work we report on new optically pumped THz laser lines from deuterated formic acid (DCOOD). An isotopic (CO2)-C-13 laser was used for the first time as a pump source for this molecule, and a Fabry-Perot cavity was used as a THz laser resonator. Optoacoustic absorption spectra were used as a guide to search for new THz laser lines. We could observe six new laser lines in the range from 303.8 mu m (0.987 THz) to 725.1 mu m (0.413 THz). The lines were characterized according to wavelength, relative polarization, relative intensity, and optimum working pressure. The transferred lamb-dip technique was used to measure the frequency absorption transition for both of these laser lines. Furthermore, we also present a catalogue of all THz laser lines generated from DCOOD.
Resumo:
A method for improving the accuracy of surface shape measurement by multiwavelength holography is presented. In our holographic setup, a Bi12TiO20 photorefractive crystal was the holographic recording medium, and a multimode diode laser emitting in the red region was the light source in a two-wave mixing scheme. on employing such lasers the resulting holographic image appears covered with interference fringes corresponding to the object relief, and the interferogram spatial frequency is proportional to the diode laser's free spectral range (FSR). Our method consists in increasing the effective free spectral range of the laser by positioning a Fabry-Perot etalon at the laser output for mode selection. As larger effective values of the laser FSR were achieved, higher-spatial-frequency interferograms were obtained and therefore more sensitive and accurate measurements were performed. The quantitative evaluation of the interferograms was made through the phase-stepping technique, and the phase map unwrapping was carried out through the cellular-automata method. For a given surface, shape measurements with different interferogram spatial frequencies were performed and compared with respect to measurement noise and visual inspection. (c) 2007 Society of Photo-Optical Instrumentation Engineers.
Resumo:
Organic-inorganic hybrids containing methacrylic acid (McOH, CH(2)= C(CH(3))COOH)) modified zirconium tetrapropoxide, Zr(OPr(n))(4), classed as di-ureasil-zirconium oxo-cluster hybrids, have been prepared and structurally characterized by X-ray diffraction (XRD), small-angle X-ray scattering (SAXS), Fourier transform infrared (FT-IR) and Raman (FT-Raman) spectroscopies, Si and C nuclear magnetic resonance (NMR), and atomic force microscopy (AFM). XRD and SAXS results have pointed out the presence of Si- and Zr-based nanobuilding blocks (NBBs) dispersed into the organic phase. Inter-NBBs correlation distances have been estimated for the pure di-ureasil and a model compound obtained. by hydrolysis/condensation of Zr(OPr(n))(4):McOH (molar ratio 1: 1): d(Si) approximate to 26 +/- 1 angstrom and d(Zr) approximate to 16 +/- 1 angstrom, respectively. In the case of the di-ureasil-zirconium oxo-cluster hybrids, these distances depend on the Zr relative molar percentage (rel. mol. Zr %) (d(Si) ranges from 18 to 25 angstrom and d(Zr) from 14 to 23 angstrom, as the rel. mol. Zr % increases from 5 to 75), suggesting that the Si- and Zr-based clusters are interconstrained. Complementary data from FT-IR, FT-Raman, (29)Si and (13)C NMR, and AFM support to a structural model where McOH-modified Zr-based NBBs (Zr-OMc) are present over the whole range of composition. At low Zr-OMc contents (rel. mol. Zr % <30) the clusters are well-dispersed within the di-ureasil host, whereas segregation occurs at the 0.1 mu m scale at high Zr-OMc concentration (rel. mol. Zr % = 50). No Zr-O-Si heterocondensation has been discerned. Monomode waveguides, diffractions gratings, and Fabry-Perot cavities have been written through the exposure of the hybrid monoliths to UV light. FT-Raman has shown that the chemical process that takes place under illumination is the polymerization of the methacrylate groups of the Zr-OMc NBBs. The guidance region in patterned channels is a Gaussian section located below the exposed surface with typical dimensions of 320 mu m wide and 88 mu m deep. The effective refractive index is 1.5162 (maximum index contrast on the order of 1 x 10(-4)) and the reflection coeficient of the Fabry-Perot cavity (formed by a grating patterned into a 0.278 cm channel) is 0.042 with a free spectral range value of 35.6 GHz.
Resumo:
The application of multi-wavelength holography for surface shape measurement is presented. In our holographic setup a Bi12TiO 20 (BTO) photorefractive crystal was the holographic recording medium and a multimode diode laser emitting in the red region was the light source in a two-wave mixing scheme. The holographic imaging with multimode lasers results in multiple holograms in the BTO. By employing such lasers the resulting holographic image appears covered of interference fringes corresponding to the object relief and the interferogram spatial frequency is proportional to the diode laser free spectral range (FSR). We used a Fabry-Perot étalon at the laser output for laser mode selection. Thus, larger effective values of the laser FSR were achieved, leading to higher-spatial frequency interferograms and therefore to more sensitive and accurate measurements. The quantitative evaluation of the interferograms was performed through the phase stepping technique (PST) and the phase map unwrapping was carried out through the Cellular-Automata method. For a given surface, shape measurements with different interferogram spatial frequencies were performed and compared, concerning measurement noise and visual inspection.
Resumo:
In this work, we report new optically pumped terahertz laser lines from DCOOD. An isotopic 13CO2 laser was used for first time as pump source, and a Fabry-Perot open cavity was used as a terahertz laser resonator. Optoacoustic absorption spectra were used as a guide to search for new terahertz laser lines. We could observe six new laser lines in the range from 303.8μm (0.987 THz) to 725.1μm (0.413 THz). The lines were characterized according to wavelength, relative polarization, relative intensity, and optimum working pressure. The transferred Lamb-dip technique was used to measure the frequency absorption transition both for this laser lines. © 2008 American Institute of Physics.
Resumo:
Objective: Crohn's disease is a chronic inflammatory process that has recently been associated with a higher risk of early implant failure. Herein we provide information on the impact of colitis on peri-implant bone formation using preclinical models of chemically induced colitis. Methods: Colitis was induced by intrarectal instillation of 2,4,6-trinitro-benzene-sulfonic-acid (TNBS). Colitis was also induced by feeding rats dextran-sodium-sulfate (DSS) in drinking water. One week after disease induction, titanium miniscrews were inserted into the tibia. Four weeks after implantation, peri-implant bone volume per tissue volume (BV/TV) and bone-to-implant contacts (BIC) were determined by histomorphometric analysis. Results: Cortical histomorphometric parameters were similar in the control (n = 10), DSS (n = 10) and TNBS (n = 8) groups. Cortical BV/TV was 92.2 ± 3.7%, 92.0 ± 3.0% and 92.6 ± 2.7%. Cortical BIC was 81.3 ± 8.8%, 83.2 ± 8.4% and 84.0 ± 7.0%, respectively. No significant differences were observed when comparing the medullary BV/TV and BIC (19.5 ± 6.4%, 16.2 ± 5.6% and 15.4 ± 9.0%) and (48.8 ± 12.9%, 49.2 ± 6.2 and 41.9 ± 11.7%), respectively. Successful induction of colitis was confirmed by loss of body weight and colon morphology. Conclusions: The results suggest bone regeneration around implants is not impaired in chemically induced colitis models. Considering that Crohn's disease can affect any part of the gastrointestinal tract including the mouth, our model only partially reflects the clinical situation. © 2012 John Wiley & Sons A/S.
Resumo:
The Advanced LIGO gravitational wave detectors are second-generation instruments designed and built for the two LIGO observatories in Hanford, WA and Livingston, LA, USA. The two instruments are identical in design, and are specialized versions of a Michelson interferometer with 4 km long arms. As in Initial LIGO, Fabry-Perot cavities are used in the arms to increase the interaction time with a gravitational wave, and power recycling is used to increase the effective laser power. Signal recycling has been added in Advanced LIGO to improve the frequency response. In the most sensitive frequency region around 100 Hz, the design strain sensitivity is a factor of 10 better than Initial LIGO. In addition, the low frequency end of the sensitivity band is moved from 40 Hz down to 10 Hz. All interferometer components have been replaced with improved technologies to achieve this sensitivity gain. Much better seismic isolation and test mass suspensions are responsible for the gains at lower frequencies. Higher laser power, larger test masses and improved mirror coatings lead to the improved sensitivity at mid and high frequencies. Data collecting runs with these new instruments are planned to begin in mid-2015.
Resumo:
We report the frequency measurements of 18 optically pumped far-infrared (FIR) laser lines generated from CD3OH and (CH3OH)-C-13. We use the heterodyne technique of mixing FIR laser radiations and microwave radiation on a metal-insulator-metal point-contact tunnel diode to determine the FIR laser frequencies. Two FIR laser systems, consisting of CO2 waveguide pump lasers and Fabry-Perot FIR laser cavities, were used as optical sources. (C) 1997 Optical Society of America.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)