17 resultados para Modelo atômico nuclear
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The teaching of modern and contemporary Physics subjects in high school is indispensable and it was already justified by several researchers. Among the subjects which must be taught, there is, for instance, Bohr atomics model. However, as it was noticed in literature review, many didactic materials do not deal with this model adequately, since that they do not take into account Bohr ideas, which involved Planck studies on black-body radiation, Einsten theory for photoelectric effect, Rutherford experiences and atomics model and the empiric results upon the spectrums of chemical elements emission. From that, it is extremely important teaching through approaches which potentialize the learning of the model proposed by Niels Bohr. On the other hand, teachers from high schools cannot have clearness about which approaches can be applied for teaching the mentioned model. Thus, it is presented some possibilities for teaching Bohr atomics model, with examples and justifications for the use of each one. Special treatment was attributed to the teaching from Science History and Philosophy, from the reading of scientific diffusion and original scientific texts, from analogies, from comic strips and from computer simulations.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper aims to give an initial presentation to physics students of the area of electron transfer, addressing its major aspects. The subject is then presented in an introductory way, highlighting and discussing the key points. Primarily, the problem is approached in a simplified manner through a two-state system, and aspects of calculating the matrix-element are discussed. Then, the electron transfer problem, influenced by nuclear reaction coordinates, is addressed and treated by the Marcus theory. Time scales and the concepts of adiabatic and nonadiabatic phenomena are discussed in the context of electron transfer. The classical, semi-classical and quantum formalisms of for the nuclear reactions coordinates are presented, and aspects of solvents are also discussed. Finally, we conclude by examining some recent examples of problems discussed in the literature.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The oral cancer model in hamsters shows many simílarities with developmental oral cancer in humans. The proliferating capacity is one the most characteristics of neoplásica ce/Is and detection of these ce/Is allow us, throughout of its counting, to achieve an estimated tumour growing index, with a consequent repercussion about prognostic and in the treatment of those lesions. 40 golden Syrian hamsters, both genders, aged between two to six mouth and weight 150g in average were used. The left síde of tangue of each animal was painted for eight consecutive weeks, with a solution of DMBA. Tongues were removed, fixed in 10% buffered fonnal solution. The histological slides were stained by AgNOR technique and by PCNA and β-catenin immunohistochemical antibodies. Statistical analyzes were performed by ANOVA one-way test and Tukey test. We may conclude that an association between AgNOR and PCNA might indicate the higher proliferating activity of the analyzed celIs. The experimental carcinogenesis model in hamster tongue is an available methodology for immunohistochemistry study. And finally, PCNA and β-catenin immunohistochemical antibodies may be used to analyze possible premalignant areas in oral leukoplakia
Resumo:
Due the differences between interaction physics process with matter for protons and photons, the proton beam tomography (pCT) has some vantages to comparison with conventional tomography. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. The pCT allow not only view the internal structure of an object without destroying it, but also directly measure of volume density of electrons. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. At the same time, there are many scientific and technical aspects to a detailed study: the capacity and limitations of the pCT methods are not well clarified. Through computations, based on Monte Carlo Method was carried out a detailed study of the contribution of non-elastic nuclear spreading, and together was compared with an analytical model for the deflection angle and the lateral deflection of protons in the target volume. The programs used were SRIM 2006 code and MCNPX v.2.50 code
Resumo:
Proteínas que apresentam atividades no núcleo e possuem sequência de localização nuclear (NLS) tem seu deslocamento dependente do heterodímero importina-α/β. A importina- (ImpA) é responsável pelo reconhecimento inicial do substrato a ser importado através da interação com os NLS. Os sinais são caracterizados por apresentar um ou mais grupos de aminoácidos básicos, denominados como sequências monopartidas e bipartidas. O fungo Neurospora crassa vem sendo utilizado há mais de 70 anos como organismo modelo em estudos de expressão gênica, desenvolvimento e diferenciação celular, ritmo circadiano, defesa do genoma, bem como outros aspectos da biologia de eucariotos. A presença de um grande número de genes no genoma de N. crassa ainda com funções desconhecidas aponta este organismo como um promissor modelo para o estudo de novos mecanismos genéticos e bioquímicos ainda não identificados. Considerando a importância do metabolismo do glicogênio para os organismos, o presente trabalho teve como objetivo o estudo estrutural de complexos de ImpA com peptídeos NLSs (NCM e NCB) de proteínas envolvidas no metabolismo de glicogênio do fungo N. crassa, utilizando técnicas de cristalografia de proteínas. Monocristais dos complexos ImpA-NCM e ImpA-NCB foram obtidos para a coleta dos dados de difração de raios-X, resultando em dois conjuntos de dados à 2,1Å e 2,45Å de resolução, respectivamente. Após elucidação da estrutura da ImpA, mapas de densidade eletrônica gerados revelaram uma densidade eletrônica no sítio principal de reconhecimento de NLS da ImpA de ambas estruturas, possibilitando modelagem dos peptídeos. Em uma comparação do mapa de densidade eletrônica obtido de ambos complexos com um mapa de uma estrutura nativa de ImpA (70-529) coletada à 2,0Å de resolução, a qual usualmente apresenta um peptídeo “contaminante” no sitio de ligação... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
As normas nacionais e internacionais prevêem que a manutenção dos níveis de radiação deve estar abaixo do permitido. Sendo assim, a ICRP [1] (International Commission on Radiological Protection) exige métodos de otimização para garantir que o público esteja exposto aos menores níveis de radiação possíveis. Como método de otimização, aproximações teóricas e semi-empiricas podem realizar uma determinação do espectro de raios-X, sendo fundamental para o diagnóstico de energia, estimando a dose de radiações em pacientes e formulando modelos de blindagem. Métodos adequados de radioproteção foram desenvolvidos na física médica como a medicina nuclear, a radioterapia e a radiologia diagnóstica. Um dos métodos semi-empiricos utilizados é o modelo de TBC que é capaz de reproduzir e calcular os espectros gerados pelo anodo de tungstênio. Com o modelo de TBC modificado é possível também obedecer às exigências das barreiras protetoras presentes na radiologia, levando em conta a forma de onda arbitrária e a filtração adicional na geração do espectro não presente no modelo original. Além disso, realiza-se a calibração do espectro gerado para que o modelo de TBC represente a quantidade e comportamento de radiações típicas. Dessa forma, realiza-se uma revisão do modelo de TBC implementando-o ao programa matemático Matlab e comparando-o com os resultados adquiridos pelo Código MCNP-5 no Método de Monte Carlo. Os resultados encontrados são bastante satisfatórios, tanto em termos quantitativos quanto qualitativos dos feixes. Para a calibração, desenvolve-se uma análise dos espectros gerados pelo TBC Modificado aplicado ao programa Mathcad e Matlab sob as mesmas condições. Os espectros gerados apresentam o mesmo comportamento, diferindo em até 12% nos valores encontrados para camadas semi-redutoras, coeficiente de homogeneidade e energia efetiva
Resumo:
Pós-graduação em Física - FEG
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)