17 resultados para Mode I
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Fatigue crack growth rate in mode I of a carbon fiber 5HS weave composite laminate processed via RTM
Resumo:
Delamination or crack propagation between plies is a critical issue for structural composites. In viewing this issue and the large application of woven fabrics in structural applications, especially the ones that requires high drapeability to be preformed in a RTM mold cavity such as the asymmetric ones, e.g HS series, this research aimed in dynamically testing the carbon fiber 5HS/RTM6 epoxy composites under opening mode using DCB set up in order to investigate the crack growth rate behavior in an irregular surface produced by the fabric waviness. The evaluation of the energy involved in each crack increment was based on the Irwin-Kies equation using compliance beam theory. The tests were conducted at constant stress ratio of R=0.1 with displacement control, frequency of 10 Hz, in accordance to ASTM E647-00 for measurement of crack growth rate. The results showed large scatter when compared to unidirectional carbon fiber composites due to damage accumulation at the fill tows.
Resumo:
For the development of this graduate work of fractal fracture behavior, it is necessary to establish references for fractal analysis on fracture surfaces, evaluating, from tests of fracture tenacity on modes I, II and combined I / II, the behavior of fractures in fragile materials, on linear elastic regime. Fractures in the linear elastic regime are described by your fractal behavior by several researchers, especially Mecholsky JJ. The motivation of that present proposal stems from work done by the group and accepted for publication in the journal Materials Science and Engineering A (Horovistiz et al, 2010), where the model of Mecholsky could not be proven for fractures into grooved specimens for tests of diametric compression of titania on mode I. The general objective of this proposal is to quantify the distinguish surface regions formed by different mechanisms of fracture propagation in linear elastic regime in polymeric specimens (phenolic resin), relating tenacity, thickness of the specimens and fractal dimension. The analyzed fractures were obtained from SCB tests in mode I loading, and the acquisition of images taken using an optical reflection microscope and the surface topographies obtained by the extension focus method of reconstruction, calculating the values of fractal dimension with the use of maps of elevations. The fractal dimension was classified as monofractal dimension (Df), when the fracture is described by a single value, or texture size (Dt), which is a macroscopic analysis of the fracture, combined with the structural dimension (Ds), which is a microscopic analysis. The results showed that there is no clear relationship between tenacity, thickness and fractal values for the material investigated. On the other hand it is clear that the fractal values change with the evolution of cracks during the fracture process ... (Complete abstract click electronic access below)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
The present study evaluated the use of semicircular bending test (SCB) as an alternative to conventional bending test to examine the effect of thermal shock. Still, studies the behavior of fracture surfaces generated by monofractal behavior analysis, which allows us to evaluate the contributions of the microstructure and the mechanical context in forming reliefs during the crack propagation. The fractal analysis is made from elevation maps obtained by reconstruction method by extension of the focus stacks of digital images acquired in microscope. The specimens used were samples semicircular pressed TiO2 (rutile) with and without heat shock, prepared for testing mode I loading. Were also produced, specimens in the form of bars for Weibull statistical analysis. From the three-point bending test, we found the variation of fracture toughness between the samples after the heat shock and natural condition. The SCB test was feasible for the analysis of thermal shock resistance. The results showed that the value of the fracture toughness decreases as the heat shock treatment
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The metabolic switch From C-3-photosynthesis to crassulacean acid metabolism (CAM),and the antioxidative response of Mesembryanthemum crystallinum L. plants cultured under severe salt stress and high light intensities, and a combination of booth stress conditions, were studied. High light conditions led to a more rapid CAM induction than salinity. The induction time was still shortened when both stress factors were combined. A main pattern observed in CAM plants was a decrease in mitochondrial Mn-superoxide dismutase (SOD) activity during the day. The activities of the chloroplastic Fe-SOD and cytosolic CuZn-SOD were increased due to salt treatment after a lag phase, while catalase activity was decreased. Combination of salt and light stress did not lead to a higher SOD activity as found after application of one stress factor alone, indicating that there is a threshold level of the oxidative stress response. The fact that salt-stressed plants grown under high light conditions showed permanent photoinhibition and lost the ability for nocturnal malate storage after 9 d of treatment indicate serious malfunction of metabolism, leading to accelerated senescence. Comparison of CuZn-SOD activity with CuZn-SOD protein amount, which was determined immunologically, indicates that the activity of the enzyme is at least partially post-translationally regulated.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
1. A method for obtaining the end-systolic left ventricular (LV) pressure-diameter and stress-diameter relationships in man was critically analyzed.2. Pressure-diameter and stress-diameter relationships were determined throughout the cardiac cycle by combining standard LV manometry with M-mode echocardiography. Nine adult patients with heart disease and without heart failure were studied during intracardiac catheterization under three different conditions of arterial pressure, i.e., basal (B) condition (mean +/- SD systolic pressure, 102 +/- 10 mmHg) and two stable states of arterial hypertension (H(I), 121 +/- 12 mmHg; H(II), 147 +/- 17 mmHg) induced by venous infusion of phenylephrine after parasympathetic autonomic blockade with 0.04 mg/kg atropine.3. Significant reflex heart rate variation with arterial hypertension was observed (B, 115 +/- 20 bpm; H(I), 103 +/- 14 bpm; H(II), 101 +/- 13 bpm) in spite of the parasympathetic blockade with atropine. The linear end-systolic pressure-diameter and stress-diameter relationships ranged from 53.0 to 160.0 mmHg/cm and from 97.0 to 195.0 g/cm3, respectively.4. The end-systolic LV pressure-diameter and stress-diameter relationship lines presented high and variable slopes. The slopes, which are indicators of myocardial contractility, are susceptible to modifications by small deviations in the measurement of the ventricular diameter or by delay in the pressure curve recording.
Resumo:
A CMOS low-voltage, wide-band continuous-time current amplifier is presented. Based on an open-loop topology, the circuit is composed by transresistance and transconductance stages built around triode-operating transistors. In addition to an extended dynamic range, the amplifier gain can be programmed within good accuracy by the rapport between the aspect-ratio of such transistors and tuning biases Vxand Vy. A balanced current-amplifier according to a single I. IV-supply and a 0.35μm fabrication process is designed. Simulated results from PSPiCE and Bsm3v3 models indicate a programmable gain within the range 20-34dB and a minimum break-frequency of IMHz @CL=IpF. For a 200 μApp-level, THD is 0.8% and 0.9% at IKHz and 100KHz, respectively. Input noise is 405pA√Hz @20dB-gain, which gives a SNR of 66dB @1MHz-bandwidth. Maximum quiescent power consumption is 56μ W. © 2002 IEEE.
Resumo:
This paper presents an efficiency investigation of an isolated high step-up ratio dc-dc converter aimed to be used for energy processing from low-voltage high-current energy sources, like batteries, photovoltaic modules or fuel-cells. The considered converter consists of an interleaved active clamp flyback topology combined with a voltage multiplier at the transformer secondary side capable of two different operating modes, i.e. resonant and non-resonant according to the design of the output capacitors. The main goal of this paper is to compare these two operating modes from the component losses point of view with the aim of maximize the overall converter efficiency. The approach is based on losses prediction using steady-state theoretical models (designed in Mathcad environment), taking into account both conduction and switching losses. The models are compared with steady-state simulations and experimental results considering different operating modes to validate the approach. © 2012 IEEE.