12 resultados para Miniscleral contact lens

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The artificial iris is the structure responsible for the dissimulation and aesthetics of ocular prosthesis. The objective of the present study was to evaluate the color stability of artificial iris of microwaveable polymerized ocular prosthesis, as a function of paint type, drying method and accelerated aging. A total of 40 discs of microwaveable polymerized acrylic resin were fabricated, and divided according to the blue paint type ( n = 5): hydrosoluble acrylic, nitrocellulose automotive, hydrosoluble gouache and oil paints. Paints where dried either at natural or at infrared light bulb method. Each specimen was constituted of one disc in colorless acrylic resin and another colored with a basic sclera pigment. Painting was performed in one surface of one of the discs. The specimens were submitted to an artificial aging chamber under ultraviolet light, during 1008 h. A reflective spectrophotometer was used to evaluate color changes. Data were evaluated by 3-way repeated-measures ANOVA and the Tukey HSD test (alpha = 0.05). All paints suffered color alteration. The oil paint presented the highest color resistance to artificial aging regardless of drying method. (C) 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Analisar o perfil dos usuários de lentes de contato entre os estudantes de medicina da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista - UNESP - Botucatu (SP), quanto à ametropia, à aquisição, aos cuidados e às complicações. MÉTODOS: Foi aplicado um questionário aos alunos do 1º ao 6º ano de Medicina da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista - UNESP - Botucatu (SP), perfazendo um estudo analítico transversal. RESULTADOS: Foram 566 entrevistados. Destes, 155 (27,4%) usavam lente de contato. Das lentes de contato usadas, 94,8% eram gelatinosas, e em 98,7% o grau era negativo. O descarte dessas lentes era mensal em 46,9% dos entrevistados e 63,9% a utilizavam, em média, 14 horas/dia. Faziam aquisição da lente de contato em óptica ou farmácia 14,1% dos estudantes. Faziam a higiene ao colocá-las e ao retirá-las dos olhos, 46,5%. As complicações referentes aos olhos vermelhos eram 51,0%; 44,5%, embaçamento; e 42,6%, sensação de corpo estranho, além de 4 estudantes relatarem ceratite. CONCLUSÕES: A maioria dos alunos utilizava lentes hidrofílicas, descarte mensal e grau negativo. A adaptação inadequada, aquisição de lentes de contato em ópticas ou farmácias e complicações graves ocorreram, mesmo nos usuários socioculturalmente considerados diferenciados. em vista disso, demanda a extrema necessidade de maior atenção na abordagem do tema em questão, a fim de prevenir o comprometimento visual permanente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To detect normal values of red phenol thread test in the Brazilian population and compare it between different races, age and sex. Methods: 280 white individuals (560 eyes) and 280 non-white individuals (560 eyes) were analyzed regarding sex and age, and analyzed using the Phenol Red test. Individuals with ocular diseases, contact lens or ocular drug users were excluded from this study. Results: Of the 1,120 evaluated eyes, the mean ± standard deviation result was 19,77±7,90 mm. Conclusion: The mean result found in this study was an intermediate value compared to the previously studied populations (Japanese and American).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To analyze the conditions, consequences and risks of self-medication in patients attended in ophthalmology emergency room at Hospital das Clínicas de Botucatu (UNESP). Methods: Sixty patients who had used any form of self-medication were studied according: age, sex, professional activity, mainly complain, visual acuity (best-corrected vision), who administrated the self-medication (friends/parents, pharmacy clerk, advertisement, or the person himself), sort of medication or product used (eyedrops/ointments/contact lenses), cost (R$), time expenditure to medical attention, ocular complications, risk of visual loss and final diagnose. Results: The majority of patients with self-medication were male (72%). The mean age was 40,9 years (7-77 years). Patients usually used eyedrops that they had at home and delayed 3 days to the first medical evaluation. The most frequently kind of topical eyedrop used was vasoconstrictor (17%). However, many patients even knew what kind of medication they had dropped in their eyes (21%). The great majority of the patients (68%) were exposed to the risk of visual loss. According to our results, self-medication may cause visual complications in 12% of patients, in which, 42% was related to the contact lenses fit without ophthalmologic assistance. Conclusion: The majory of the patients used medication that they had in home. The topical vasoconstrictor was the most frequently used drug, however, they did not know which medication were dropping in their eyes (21%).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the roughness of colorless ocular button and four brands of colorless acrylic resins designed to fabricate ocular prosthesis as a function of weathering (1008 h) and different thickness (1 and 3.5 mm). Materials and methods: One-hundred-and-twenty specimens were fabricated and distributed in 12 groups. The analysis was carried out by means of digital roughness meter. Results: Data were analyzed statistically by ANOVA and Tukey test at 1% significance. The results showed that there was no statistically significant difference after the weathering period. Both the Vipi Cril acrylic resin with 3.5 mm in thickness and ocular button with 1 mm in thickness presented the lowest roughness values (0.12. Ra). Conclusion: The roughness of the acrylic resins and the ocular button was not affect by the weathering of 1008 h. However, the thickness of the specimens proved to have a major influence on roughness property. © 2010.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: The present case report described the use of contact lens of thin porcelain veneers as a restorative therapy to solve anterior teeth disharmony. Background: Fragments of thin veneers are minimally invasive restorations with little or no dental preparation and present thickness ranging from 0.2 to 0.5 mm. They are used in case of diastema closure, small changes of teeth, color and restoration of teeth with small fractures. Case report: A 25-year-old man was admitted at a dental clinic complaining about the diastema presence on the upper anterior teeth. Patient was referred to an orthodontic treatment in order to provide better distribution of the diastemas and harmonious proportion of the teeth. Afterwards, contact lens of thin porcelain veneers were fabricated on the six upper anterior teeth. Conclusion: Based on the outcomes of this clinical report, we considered the use of fragments of thin veneers as a successful treatment option after 3 years of follow-up. Clinical significance: The fragments of thin veneers have been established to be an interesting alternative to esthetically restore the anterior teeth with minimal invasiveness. However, since it is a new treatment modality, longitudinal studies are necessary to understand the material's behavior.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)