43 resultados para Minerva (Brigantine)

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Educação para a Ciência - FC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to our conceptions, to study the so called Projeto Minerva (PMi) – an action of Brazilian Military Dictatorship, implemented in the 1970s, which intended to provide access to Primary and Secondary Schools for thousands of Brazilians throughout the country, using a cheap, and at that time a widely -spread medium, the radio – implies to study not only a unique education strategy, but a variety of circumstances that allows it to be created and developed throughout its 10 years of existence in various Brazilian locations. Each circumstance, each region, each way of doing of each person involved in its development constitutes a different Minerva – that’s why we choose the plural to treat it: the Minerva ProjectS. In this paper we present one of the many possible histories about such project. Synthetically, we present some historiographical aspects of its creation, development and extinction and, based on a study about one of its lessons (related to Analitic Geometry), we try to evidence differences between a spoken mathematics and a written mathematics. According to the the oretical framework used in this text, inspired by the Wittgenstein's language philosophy, the Project articulates various mathematics, what is different of saying that the project deals with the "usual" Mathematics merely changing the way of communicate it.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Autologous vein (AV) is sometimes not suitable or present for a vascular restoration. Homologous vein preserved in glutaraldehyde may be an alternative to AV, but little is yet known about this graft and its healing process after implantation in arteries. The purpose of this study was to compare the initial healing process of glutaraldehyde-tanned homologous venous grafts (group 1) with fresh autologous venous grafts (group 2), at 4 or 15 days.Methods. Forty Norfolk rabbits were allocated in 2 groups of 20 animals each. The grafts was interposed in the infra-renal aorta of the rabbit. Anastomotic tensile strength (TS), hydroxyproline (HP) determination, and histology (HA) were performed.Results. TS increased in both groups, from the 4th to 15th day, (p < 0.01) in both proximal (G1: from 364.5 &PLUSMN; 98.3 g to 491.8 &PLUSMN; 107.3 g; G2: from 366.26 &PLUSMN; 85.15 g to 518.46 &PLUSMN; 82.79 g) and distal anastomosis (GI: from 363.53 &PLUSMN; 96.26 g to 507.32 &PLUSMN; 91.01 g; G2: from 352.30 &PLUSMN; 102.41 g to 528.67 &PLUSMN; 48.58 g), with no difference between the groups. HP did not change (p > 0.10) in this same period and was similar in both groups, in the proximal (GI: from 677.99 +/- 153.98 mug/100 mg to 914.92 +/- 459.83 mug/100 mg; G2: from 668.65 +/- 170.28 mug/100 mg to 669.46 +/- 319.80 mug/100 mg) as well as in the distal anastomosis (G1:from 740.07 +/- 213.53 mug/100 mg to 923.52 +/- 270.57 mug/100 mg; G2: from 737.66 +/- 266.76 mug/100 mg to 707.68 +/- 171.25 mug/100 mg). Initial inflammatory and reparative features of the anastomosis were similar in both groups.Conclusion. We can conclude that the healing process of the glutaraldehyde-tanned homologous vein graft was similar to that of the fresh autologous venous graft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Extrinsic compression of the popliteal artery and absence of surrounding anatomical abnormalities characterize the functional popliteal artery entrapment syndrome (PAES). The diagnosis is confirmed to individuals who have typical symptoms of popliteal entrapment and occlusion or important stenosis of the popliteal artery with color duplex sonography (CDS), magnetic resonance imaging (MRI) or arteriography during active plantar flexion-extension maneuvers. However, variable result findings in normal asymptomatic subjects have raised doubts as to the validity of these tests. The purpose of this study was to compare the frequency of popliteal artery compression in 2 groups of asymptomatic subjects, athletes and non-athletes.Methods. Forty-two individuals were studied. Twenty-one subjects were indoor soccer players, and 21 were sedentary individuals. Physical activity was evaluated through questionnaires, anthropometric measurements, and cardiopulmonary exercise test. Evaluation of popliteal artery compression was performed in lower limbs with CDS, ankle-brachial index (ABI) measurements and continuous wave Doppler of the posterior tibial artery.Results. The athletes studied fulfilled the criteria of high level of physical activity whereas sedentary subjects met the criteria of low level of activity. Popliteal artery compression was observed with CDS in 6 (14.2%) studied subjects; 2 of whom (4.7%) were athletes and 4 (9.5%) were non-athletes. This difference was not statistically significant (p=0.21). Doppler of the tibial arteries and ABI measurements gave good specificity and sensibility in the identification of popliteal artery compression.Conclusion. The frequency of popliteal artery compression during maneuvers in normal subjects was 14.2% irrespective of whether or not they performed regular physical activities. Both Doppler and ABI showed good agreement with CDS and should be considered in screening popliteal arteries in individuals suspected of PAES.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Lower-limb traumatic injury associated with ischemia and followed by reperfusion (I/R) is a common severe situation in muscle lesions due to trauma and hypoxia followed by local and systemic injuries induced by oxygen-derived free radical release during reperfusion. The aim of this study was to evaluate the attenuating effects of trimetazidine (TMZ) and N-acetylcysteine (NAC) in such situation.Methods. The muscles at the root of the right hind limb of Wistar rats were cross-sectioned, preserving femoral vessels and nerves and clamping the femoral artery for four hours. The clamp was then released and the femoral artery has been reperfused for 2 hours. Rats were randomly divided in groups of ten as follows: Group 1: sham I/R, treated with saline; Group 2: I/R, treated with saline; Group 3: sham I/R, treated with TMZ (7.5 mg/kg/dose); Group 4: sham I/R, treated with NAC (375 mg/kg/dose); Group 5: I/R treated with TMZ (7.5 mg/kg/dose); Group 6: I/R treated with NAC (375 mg/kg/dose). All rats received two intravenous bolus injections of the drugs, one before ischemia and one before reperfusion. Oxidative stress in plasma (MDA, total, oxidized and reduced glutathione), creatinephosphokinase (CPK), optical and electron microscopy and pelvic extremity circumference and volume were studied.Results. No statistical differences were found between the groups for MDA or total and reduced glutathione. Oxidized glutathione increased significantly in groups 5 and 2. Limb circumference as well as limb volume increased in all groups over time, mainly in groups 5, 2 and 1. CPK increased in all groups, being highest in groups 5, 6 and 2. Histological lesions were present in all but sham groups, being less severe in group 6. Soleus muscle analyses at electron microscopy exhibit some degree of alteration in all groups.Conclusion. This experimental model simulated severe limb trauma associated with ischemia and reperfusion, and, as such, it was aggressive, causing severe injury and local inflammatory reaction. The model did not show antioxidant action from NAC, and possible antioxidant action from TMZ was insufficient to attenuate tissue injuries. [Int Angiol 2009;28:412-7]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Superficial thrombophlebitis (ST) ascending the lower limbs is a common disease, which may be associated with deep vein thrombosis (DVT) and pulmonary embolism (PE). The aim of this study was to investigate the prevalence of DVT and PE as complications of ascending ST of the lower limbs in the great saphenous vein (GSV) or SSV (SSV) and probable risk factors.Methods. For this study 60 consecutive patients were enrolled with ascending ST of the GSV or SSV, seen between 2000 and 2003 at a public hospital in Botucatu, SP, Brazil. All patients were assessed clinically, by venous Duplex scanning of the lower limbs to confirm ST and test for DVT, and by means of pulmonary scintigraphy to test for PE.Results. In 13 ST cases (21.67%) there was concomitant DVT and 17 ST patients (28.33%) also had PE. Eleven patients had a clinical status suggestive of DVT, but only in eight of these (61.5%), this clinical diagnosis was confirmed. Fourteen patients had a clinical status suggestive of PE, and this diagnosis was confirmed in six cases (35.30%). ST patients who also had DVT and/or PE were given anticoagulant treatment with heparin and warfarin. None of the variables studied was predictive of DVT or PE (P>0.05). However, the presence of varicose veins reduced the risk of patients having DVT (relative risk=9.09; 95%CI:1.75 - 50.00 and P=0.023).Conclusion. The prevalence rates of PE (28.3%) and DVT (21.6%) were elevated in this sample of ascending ST cases, indicating a need for detailed assessment of patients for signs of these complications, including for therapeutic management decision making. [Int Angiol 2009;28:400-8]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. The authors assess a modified Greenfield filter (GF) for the long-term patency, filter tilting and histopathologic alterations of the inferior vena cava (IVC).Methods. Adult sheep (n=7) underwent modified GF placement in the IVC. Cavograms were obtained every 3 months and pulmonary angiography at 12 months. Histopathologic and scanning electron microscopy (SEM) analyses were performed on the IVC explanted at 12 months.Results. Cavograms showed that all IVC were patent at the end of the study. Filter tilting occurred in 2/7 animals and extrusion of struts was not observed. Macroscopic examination at explantation showed minimal venous wall thickening. Microscopic examination showed minimal IVC fibrosis and intimal hyperplasia. SEM showed endothelium on the IVC surface at the filter implantation site and a presumed endothelial layer covering partially or totally the struts. The interface filter-IVC was covered by deposits of leucocytes and platelets. No signs of pulmonary embolism were found in all pulmonary angiograms of both groups.Conclusion. The modified filter presented good biocompatibility, stability and absence of thrombogenicity at 12 months. It presented low tendency to tilting and extrusion of struts. The long-term histopathologic alterations in vena caval wall were minimal and the appearance of the studied filters in the IVC was similar to stents placed in the arterial system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The running velocities associated to lactate minimum (V-lm), heart rate deflection (V-HRd), critical velocity (CV), 3000 M (V-3000) and 10000 m performance (V-10km) were compared. Additionally the ability of V-lm and VHRd on identifying sustainable velocities was investigated.Methods. Twenty runners (28.5 +/- 5.9 y) performed 1) 3000 m running test for V3000; 2) an all-out 500 in sprint followed by 6x800 m incremental bouts with blood lactate ([lac]) measurements for V-lm; 3) a continuous velocity-incremented test with heart rate measurements at each 200 m for V-HRd; 4) participants attempted to 30 min of endurance test both at V-lm(ETVlm) and V-HRd(ETVHRd). Additionally, the distance-time and velocity-1/time relationships produced CV by 2 (500 m and 3000 m) or 3 predictive trials (500 m, 3000 m and distance reached before exhaustion during ETVHRd), and a 10 km race was recorded for V-10km.Results. The CV identified by different methods did not differ to each other. The results (m(.)min(-1)) revealed that V-.(lm) (281 +/- 14.8)< CV (292.1 +/- 17.5)=V-10km (291.7 +/- 19.3)< V-HRd (300.8 +/- 18.7)=V-3000 (304 +/- 17.5) with high correlation among parameters (P < 0.001). During ETVlm participants completed 30 min of running while on the ETVHRd they lasted only 12.5 +/- 8.2 min with increasing [lac].Conclusion. We evidenced that CV and Vim track-protocols are valid for running evaluation and performance prediction and the parameters studied have different significance. The V-lm reflects the moderate-high intensity domain (below CV), can be sustained without [lac] accumulation and may be used for long-term exercise while the V-HRd overestimates a running intensity that can be sustained for long-time. Additionally, V-3000 and V-HRd reflect the severe intensity domain (above CV).